Improving Building Design and Operation of a Thai Buddhist Temple

In this paper we report the results of coupled DOE-2 and 3D transient computational fluid dynamics (CFD) simulations for an unconditioned 100-year-old Buddhist temple, located in an urban area of Bangkok, Thailand. The HEATX CFD code was combined with the DOE-2 thermal simulation program, to analyze the heat transfer and airflow performance of the building. The indoor temperatures simulated by both programs were validated with measured temperature taken at the site. The simulation indicated poor thermal comfort conditions in this temple. The transient CFD/DOE-2 simulation suggested several remedial changes that could be implemented to improve the indoor comfort. In addition, a prototype building that combined several improved design options was proposed, and the simulation of the prototype was then performed. The result indicated an improvement of the indoor thermal comfort compared with that of the current building.

[1]  Qingyan Chen,et al.  Natural Ventilation Design for Houses in Thailand , 2001 .

[2]  S. Patankar Numerical Heat Transfer and Fluid Flow , 2018, Lecture Notes in Mechanical Engineering.

[3]  Jelena Srebric,et al.  A Coupled Airflow and Energy Simulation Program for Indoor Thermal Environmental Studies , 2000 .

[4]  Cezar O.R. Negrão,et al.  CONFLATION OF COMPUTATIONAL FLUID DYNAMICS AND BUILDING THERMAL SIMULATION , 1995 .

[5]  M. J. Andrews,et al.  Three dimensional numerical simulation of shell-and-tube heat exchangers. Part I: Foundation and fluid mechanics , 1998 .

[6]  Leon R. Glicksman,et al.  Simulation of wind driven ventilative cooling systems for an apartment building in Beijing and Shanghai , 2002 .

[7]  Malcolm J. Andrews,et al.  The simulation of mixing layers driven by compound buoyancy and shear , 1996 .

[8]  D. C. Hittle,et al.  Calibrating building energy analysis models using short term test data , 1996 .

[9]  M. J. Andrews,et al.  THREE-DIMENSIONAL NUMERICAL SIMULATION OF SHELL-AND-TUBE HEAT EXCHANGERS. PART II: HEAT TRANSFER , 1998 .

[10]  Chen Qingyan,et al.  Accuracy ― A program for combined problems of energy analysis, indoor airflow, and air quality , 1988 .

[11]  S. Chandra,et al.  Heat transfer in naturally ventilated rooms: Data from full-scale measurements , 1984 .

[12]  Jeff Haberl,et al.  Use of Calibrated Simulation for the Evaluation of Residential Energy Conservation Options of Two Habitat for Humanity Houses in Houston, Texas , 1998 .

[13]  R. C. Kammerud VENTILATION COOLING OF RESIDENTIAL BUILDINGS , 1983 .

[14]  Fred Bauman,et al.  Natural convection in passive solar buildings: experiments, analysis, and results , 1981 .

[15]  T. E. Bou-Saada,et al.  An Improved Procedure for Developing Calibrated Hourly Simulation Models , 1995 .

[16]  Jeff Haberl,et al.  Procedures for Calibrating Hourly Simulation Models to Measured Building Energy and Environmental Data , 1998 .