Noninvasive glucose monitoring: comprehensive clinical results. Cygnus Research Team.

ContextIntensive diabetes management using frequent blood glucose measurements to guide therapy has been shown to significantly improve short- and long-term outcomes. Development of a device that makes possible frequent, automatic, painless, and accurate measurements of glucose would facilitate intensive management.ObjectiveTo determine the accuracy of the GlucoWatch automatic glucose biographer (Cygnus Inc) compared with that of serial blood glucose measurements.DesignMulticenter comparative study of the GlucoWatch biographer and the HemoCue blood glucose analyzer (Aktiebolaget Leo) performed between August 29 and October 17, 1998. Participants wore up to 2 biographers during the 15-hour study session and performed 2 fingersticks per hour for comparative blood glucose measurements. The biographers were calibrated with a single HemoCue measurement after a 3-hour warm-up period. Diet and insulin were manipulated to produce a broad glycemic range during the study.SettingControlled clinical environment at 2 diabetes centers and 3 contract research organizations in the United States.ParticipantsA total of 92 subjects (mean [SD] age, 42.1 [15.1] years; 59.8% women) with type 1 or 2 diabetes requiring treatment with insulin.Main Outcome MeasuresMean error, mean absolute error, correlation, slope, and intercept using Deming regression, and clinical significance of differences between biographer readings and blood glucose measurements using the Clarke error grid.ResultsResults showed close tracking of blood glucose over a range of 2.2 to 22.2 mmol/L (40-400 mg/dL) for up to 12 hours using a single point calibration. The biographer readings lagged behind serial blood glucose values by a mean of 18 minutes. An analysis of 2167 data pairs shows a linear relationship (r = 0.88; slope = 1.03; intercept = −0.33 mmol/L [−6 mg/dL]) between biographer readings and serial glucose measurements. The mean absolute error between the 2 measurements was 15.6% (mean error [SD], −0.07 [1.82] mmol/L [−1 {33} mg/dL]), and 96.8% of the data fell in the therapeutically relevant regions of the error grid analysis.ConclusionThese results demonstrate close agreement between GlucoWatch biographer readings and blood glucose measurements using repeated fingerstick blood samples. The automatic, frequent, and noninvasive measurements obtained with the biographer provides more information about glucose levels than the current standard of care.

[1]  John H. Draize,et al.  METHODS FOR THE STUDY OF IRRITATION AND TOXICITY OF SUBSTANCES APPLIED TOPICALLY TO THE SKIN AND MUCOUS MEMBRANES , 1944 .

[2]  D. Cox,et al.  Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood Glucose , 1987, Diabetes Care.

[3]  Ayse G. Canseven,et al.  Electrical Properties of The Skin , 1992 .

[4]  S. Genuth,et al.  The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. , 1993, The New England journal of medicine.

[5]  康生 大久保,et al.  Intensive insulin therapy prevents the progression of diabetic microvascular complications in Japanese patients with non-insulin-dependent diabetes mellitus : a randomized prospective 6-year study , 1995 .

[6]  Evaluation of a Second‐generation Electrochemical Blood Glucose Monitoring System , 1995, Diabetic medicine : a journal of the British Diabetic Association.

[7]  Russell O. Potts,et al.  Measurement of glucose in diabetic subjects using noninvasive transdermal extraction , 1995, Nature Medicine.

[8]  G Reach,et al.  Use of a subcutaneous glucose sensor to detect decreases in glucose concentration prior to observation in blood. , 1996, Analytical chemistry.

[9]  Z. Trajanoski,et al.  Accuracy of home blood glucose meters during hypoglycemia , 1996, Diabetes Care.

[10]  U. Ungerstedt,et al.  Self-Monitoring of Blood Glucose in Type I Diabetic Patients: Comparison With Continuous Microdialysis Measurements of Glucose in Subcutaneous Adipose Tissue During Ordinary Life Conditions , 1997, Diabetes Care.

[11]  P Wach,et al.  Validation of Home Blood Glucose Meters With Respect to Clinical and Analytical Approaches , 1998, Diabetes Care.

[12]  R. Holman,et al.  Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33). UK Prospective Diabetes Study (UKPDS) Group. , 1998 .

[13]  R. Potts,et al.  Design and Simulation of a Reverse Iontophoretic Glucose Monitoring Device , 1998 .

[14]  R. Bonnecaze,et al.  Measurement and modeling of the transient difference between blood and subcutaneous glucose concentrations in the rat after injection of insulin. , 1998, Proceedings of the National Academy of Sciences of the United States of America.

[15]  R. Kurnik,et al.  Application of the Mixtures of Experts algorithm for signal processing in a noninvasive glucose monitoring system , 1999 .