A novel lumped parameter model for Loop Heat Pipes – validation and parametric analysis
暂无分享,去创建一个
A one dimensional lumped parameter model has been developed within the general framework of the open source software Octave, in order to describe the physical behaviour of a Loop Heat Pipe. By means of the electro-thermal-hydraulic analogy, this model gives the values of temperature and pressure for every part of the device, in response to varying boundary conditions. Furthermore, a novel approach in describing the phase change at the condenser has been adopted, differentiating the vapour quality variation over time. The code is initially validated against both simulation and experimental data found in literature. Since the present work aims to produce a design tool for the automotive industry, a parametric analysis on the geometrical characteristics of a Loop Heat Pipe is then performed, identifying and quantifying the most influential design parameters.
[1] Yu.F. Maydanik,et al. Loop heat pipes , 2005 .
[2] Vincent Platel,et al. Dynamic response of a capillary pumped loop subjected to various heat load transients , 2004 .
[3] Jentung Ku,et al. Heat and Mass Transfer in Loop Heat Pipes , 2003 .