Image Processing Techniques for Glaucoma Detection Using the Cup-to-Disc Ratio

Glaucoma is the second leading cause of permanent blindness worldwide. Early detection of glaucoma can limit the disease progression. The ratio of the size of the optic cup to the optic disc, also known as the cup-to-disc ratio (CDR), is one of the important clinical indicators of glaucoma, and is currently determined manually by trained ophthalmologists, limiting its potential in mass screening for early detection. In this paper, the authors propose a method to calculate the CDR automatically from nonstereographic retinal fundus photographs taken from a NIDEK AFC-230, which is a non-mydriatic auto fundus camera. To automatically extract the disc, two methods making use of an edge detection method and variational level-set method are proposed in the paper. For the cup, color component analysis and threshold level-set method are evaluated. To reshape the obtained disc and cup boundary from our methods, ellipse fitting is applied to the obtained image. A set of 44 retinal images obtained from Mettapracharak Hospital, Nakhon Pathom Thailand is used to assess the performance of the determined CDR to the clinical CDR, and it is found that our proposed method provides 89% accuracy in the determined CDR results.

[1]  Andrew W. Fitzgibbon,et al.  Direct Least Square Fitting of Ellipses , 1999, IEEE Trans. Pattern Anal. Mach. Intell..

[2]  J. Liu,et al.  Level-set based automatic cup-to-disc ratio determination using retinal fundus images in ARGALI , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[3]  Andrew W. Fitzgibbon,et al.  Direct least squares fitting of ellipses , 1996, Proceedings of 13th International Conference on Pattern Recognition.

[4]  J. Liu,et al.  Optic cup and disk extraction from retinal fundus images for determination of cup-to-disc ratio , 2008, 2008 3rd IEEE Conference on Industrial Electronics and Applications.

[5]  Haizhou Li,et al.  ARGALI: An Automatic Cup-to-Disc Ratio Measurement System for Glaucoma Analysis Using Level-set Image Processing , 2009 .

[6]  J. MacQueen Some methods for classification and analysis of multivariate observations , 1967 .

[7]  R.J. Maciunas,et al.  An automatic technique for finding and localizing externally attached markers in CT and MR volume images of the head , 1996, IEEE Transactions on Biomedical Engineering.

[8]  Chunming Li,et al.  Level set evolution without re-initialization: a new variational formulation , 2005, 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05).