The effects of computed tomography scanner parameters on the quality of the reverse triangular surface model of the fibula

This study investigates the effects of computed tomography (CT) parameters on the quality and size of the reverse triangular surface model with an objective of obtaining an accurate 3D triangular surface model of complex-shaped customized objects for reverse engineering and many other applications such as surgical planning and finite element analysis. For this purpose, the fibula of a human knee joint was CT scanned by changing various parameters (slice thickness, slice spacing, pixel size, X-ray tube current and helical pitch) over wide ranges. Three-dimensional triangular surface models were created from point cloud data extracted from the CT image data. To assess the influences of scanning parameters on the surface quality and accuracy, the resulting surface models were qualitatively compared based on various anatomical features. Statistical analysis was used to quantify the deviations of surface models with different scanning parameter levels from the reference CT surface model. The results show that these parameters to a varying degree affect the surface quality, reproduction of various anatomical details and size of the resulting surface model. Moreover, these parameters are highly dependent on each other. Interactive effects of these parameters have been discussed and recommendations have been made for parameter settings. The results of the study would help to improve the accuracy of the 3D surface models required for customized implants and other applications.

[1]  Nasir Hayat,et al.  Rapid development of complex shaped customized products , 2015 .

[2]  R. Adaskevicius,et al.  Experimental Determination of Computed Tomography Settings for Jaw Scanning , 2011 .

[3]  Aldo von Wangenheim,et al.  Influence of Tomographic Slice Thickness and Field of View Variation on the Reproduction of Thin Bone Structures for Rapid Prototyping Purposes —An in Vitro Study , 2013 .

[4]  Moo K Chung,et al.  The effect of computed tomographic scanner parameters and 3-dimensional volume rendering techniques on the accuracy of linear, angular, and volumetric measurements of the mandible. , 2013, Oral surgery, oral medicine, oral pathology and oral radiology.

[5]  Jana Velemínská,et al.  Accuracy and benefits of 3D bone surface modelling: a comparison of two methods of surface data acquisition reconstructed by laser scanning and computed tomography outputs. , 2012, Collegium antropologicum.

[6]  Pierre Boulanger,et al.  Evaluation of the accuracy of Cone Beam Computerized Tomography (CBCT): medical imaging technology in head and neck reconstruction , 2013, Journal of Otolaryngology - Head & Neck Surgery.

[7]  O. Harrysson,et al.  Custom-designed orthopedic implants evaluated using finite element analysis of patient-specific computed tomography data: femoral-component case study , 2007, BMC musculoskeletal disorders.

[8]  Liang Gao,et al.  Personalized cranium defects restoration technique based on reverse engineering , 2009 .

[9]  Adir Cohen,et al.  Mandibular reconstruction using stereolithographic 3-dimensional printing modeling technology. , 2009, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[10]  D D Robertson,et al.  Three-Dimensional Analysis of the Proximal Part of the Humerus: Relevance to Arthroplasty* , 2000, The Journal of bone and joint surgery. American volume.

[11]  Mangalam Sankupellay,et al.  SIMULATION OF IMPLANT FITTING IN THE FEMUR BONE , 2005 .

[12]  Beat Schmutz,et al.  The effect of CT slice spacing on the geometry of 3D models , 2007 .

[13]  William Hoff,et al.  In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics. , 2005, Journal of biomechanics.

[14]  Miguel Ángel Martínez,et al.  A three-dimensional finite element analysis of the combined behavior of ligaments and menisci in the healthy human knee joint. , 2006, Journal of biomechanics.

[15]  Jorge Vicente Lopes da Silva,et al.  Dimensional error in selective laser sintering and 3D-printing of models for craniomaxillary anatomy reconstruction. , 2008, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[16]  S. Adeeb,et al.  Symmetry analysis of talus bone , 2014, Bone & joint research.

[17]  Basilio Ramos Barbero,et al.  Comparative study of different digitization techniques and their accuracy , 2011, Comput. Aided Des..

[18]  Karupppasamy Subburaj,et al.  Rapid development of auricular prosthesis using CAD and rapid prototyping technologies. , 2007, International journal of oral and maxillofacial surgery.

[19]  J. Asaumi,et al.  Comparison of three-dimensional computed tomography with rapid prototype models in the management of coronoid hyperplasia. , 2001, Dento maxillo facial radiology.