A Comparison of Radiation Exposure between Diagnostic CTA and DSA Examinations of Cerebral and Cervicocerebral Vessels

This article compares radiation exposure from CTA and DSA used to evaluate the extra- and intracranial circulations. Experiments were performed on a phantom using a 64-section CT scanner and biplane DSA. The authors concluded that the effective dose for CTA assessment of cerebral vessels was approximately one-fifth the dose compared with DSA. In the imaging of cervicocerebral vessels, the effective dose for CTA was approximately one-third higher compared with DSA. BACKGROUND AND PURPOSE: While the number of CTA examinations is continually increasing compared with DSA examinations, there is little comparative dose information about the different imaging techniques. We compared patient radiation exposure resulting from diagnostic CTA and DSA examinations for both cerebral and cervicocerebral vessels. MATERIALS AND METHODS: An anthropomorphic phantom was irradiated by using typical diagnostic CTA and DSA setups and imaging parameters. For both imaging techniques, the imaging area of cerebral vessels included intracranial vessels only, while the imaging area of cervicocerebral vessels included both cervical and intracranial vessels from the aortic arch to the vertex. The effective dose was determined by using RPLDs. The DSA examination was simulated by using a biplane angiography system, and the CTA examination, by using a 64-row multidetector CT scanner. RESULTS: For the imaging of cerebral vessels, the effective dose according to ICRP 103 was 0.67 mSv for CTA and 2.71 mSv for DSA. For the imaging of cervicocerebral vessels, the effective dose was 4.85 mSv for CTA and 3.60 mSv for DSA. The maximum absorbed dose (milligray) for skin, brain, salivary glands, and eyes was 166.2, 73.5, 35.6, and 21.8 mGy for DSA and 19.0, 16.9, 20.4, and 14.8 mGy for CTA, respectively. The conversion factors from DAP and DLP to effective dose were calculated. CONCLUSIONS: The effective dose for CTA assessment of cerebral vessels was approximately one-fifth the dose compared with DSA. In the imaging of cervicocerebral vessels, the effective dose for CTA was approximately one-third higher compared with DSA.

[1]  M. Tapiovaara,et al.  PCXMC. A PC-based Monte Carlo program for calculating patient doses in medical x-ray examinations , 1997 .

[2]  Y. Matsumaru,et al.  Dose Measurement on Both Patients and Operators during Neurointerventional Procedures Using Photoluminescence Glass Dosimeters , 2008, American Journal of Neuroradiology.

[3]  Hiroshi Niimi,et al.  Radiation-induced temporary hair loss as a radiation damage only occurring in patients who had the combination of MDCT and DSA , 2004, European Radiology.

[4]  Icrp ICRP Publication 60: 1990 Recommendations of the International Commission on Radiological Protection , 1991 .

[5]  J. Sjöstrand,et al.  A clinical study of radiation cataract formation in adult life following γ irradiation of the lens in early childhood , 1997 .

[6]  Geneviève Gaboriaud,et al.  ASSESSMENT OF ORGAN ABSORBED DOSES AND ESTIMATION OF EFFECTIVE DOSES FROM PEDIATRIC ANTHROPOMORPHIC PHANTOM MEASUREMENTS FOR MULTI-DETECTOR ROW CT WITH AND WITHOUT AUTOMATIC EXPOSURE CONTROL , 2009, Health physics.

[7]  A Workman,et al.  Patient dose from 3D rotational neurovascular studies. , 2007, The British journal of radiology.

[8]  Stephen Balter,et al.  Minimizing radiation-induced skin injury in interventional radiology procedures. , 2002, Radiology.

[9]  B. Modan,et al.  Increased risk of salivary gland tumors after low‐dose irradiation , 1998, The Laryngoscope.

[10]  C. Kawaura,et al.  Organ and effective dose evaluation in diagnostic radiology based on in-phantom dose measurements with novel photodiode-dosemeters. , 2006, Radiation protection dosimetry.

[11]  Julia F. Barrett,et al.  Artifacts in CT: recognition and avoidance. , 2004, Radiographics : a review publication of the Radiological Society of North America, Inc.

[12]  S. Brooks,et al.  Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT. , 2006, Dento maxillo facial radiology.

[13]  Icrp Recommendations of the International Commission on Radiological Protection Publication 60 , 1991 .

[14]  Ahmed Meghzifene,et al.  Dosimetry in diagnostic radiology. , 2010, European journal of radiology.

[15]  Donald L. Miller Overview of contemporary interventional fluoroscopy procedures. , 2008, Health physics.

[16]  K. F. Eckerman,et al.  Specific absorbed fractions of energy at various ages from internal photon sources: 2, One-year-old , 1987 .

[17]  K. Faulkner,et al.  Patient and staff dosimetry in neuroradiological procedures. , 1995, The British journal of radiology.

[18]  A. Norbash,et al.  Techniques for reducing interventional neuroradiologic skin dose: tube position rotation and supplemental beam filtration. , 1996, AJNR. American journal of neuroradiology.

[19]  B. McParland,et al.  A study of patient radiation doses in interventional radiological procedures. , 1998, The British journal of radiology.

[20]  R. Orecchia,et al.  Three-dimensional conformal postoperative radiotherapy in patients with parotid tumors: 10 years' experience at the European Institute of Oncology. , 2011, Tumori.

[21]  M. Nieminen,et al.  The applicability of radiophotoluminescence dosemeter (RPLD) for measuring medical radiation (MR) doses. , 2012, Radiation protection dosimetry.

[22]  E. Ron,et al.  Risk of radiation‐related salivary gland carcinomas among survivors of Hodgkin lymphoma , 2008, Cancer.

[23]  Diana L. Glennie,et al.  Entrance skin dose measured with MOSFETs in children undergoing interventional radiology procedures , 2008, Pediatric Radiology.

[24]  Donald L. Miller,et al.  Radiation dose and cancer risk among pediatric patients undergoing interventional neuroradiology procedures , 2006, Pediatric Radiology.

[25]  K. F. Eckerman,et al.  Specific absorbed fractions of energy at various ages from internal photon sources: 6, Newborn , 1987 .

[26]  Richard I. Aviv,et al.  Radiation dose from multidetector row CT imaging for acute stroke , 2009, Neuroradiology.

[27]  A. Mamourian,et al.  Cumulative Radiation Dose in Patients Admitted with Subarachnoid Hemorrhage: A Prospective Study Using a Self-Developing Film Badge , 2010, American Journal of Neuroradiology.

[28]  H. Bauknecht,et al.  Comparative evaluation of 64-slice CT angiography and digital subtraction angiography in assessing the cervicocranial vasculature , 2008, Vascular health and risk management.

[29]  B. Schuknecht Latest techniques in head and neck CT angiography , 2004, Neuroradiology.

[30]  W. Huda,et al.  A METHOD TO OBTAIN MEAN ORGAN DOSES IN A RANDO PHANTOM , 2008, Health physics.

[31]  C. Truwit,et al.  Multi-slice CT angiography of small cerebral aneurysms: is the direction of aneurysm important in diagnosis? , 2005, European journal of radiology.

[32]  R. Sievert,et al.  Book Reviews : Recommendations of the International Commission on Radiological Protection (as amended 1959 and revised 1962). I.C.R.P. Publication 6. 70 pp. PERGAMON PRESS. Oxford, London and New York, 1964. £1 5s. 0d. [TB/54] , 1964 .

[33]  J. Zoetelief,et al.  Recommendations for patient dosimetry in diagnostic radiology using TLD. Topical report , 2000 .

[34]  P. Meyers,et al.  Patient radiation exposure during diagnostic and therapeutic interventional neuroradiology procedures , 2009, Journal of NeuroInterventional Surgery.

[35]  Icrp Preface, Executive Summary and Glossary , 2007 .

[36]  Natalie N. Braun,et al.  Strategies for reducing radiation dose in CT. , 2009, Radiologic clinics of North America.

[37]  M Cohnen,et al.  Radiation exposure of patients in comprehensive computed tomography of the head in acute stroke. , 2006, AJNR. American journal of neuroradiology.