Biocompatibility of a silicon based peripheral nerve electrode.

The biocompatibility of a silicon neuroelectric interface for chronic use in mammalian peripheral nerves was investigated. New Zealand white rabbits were used as the animal model. The implant was made of (110) silicon coated with one micron of silicon dioxide. An anisotropic etch was used to form a grid of ten silicon bars each 40 microns wide and spaced 160 microns apart. A Silastic nerve cuff was molded onto each side of the grid. Using microsurgical techniques, the nerve was transected and sutured into the implant cuff. One implanted rabbit was completely analyzed and is reported here. By 32 days post operatively, the EMG of the affected muscles had partially recovered. The EMG of the affected muscles was indistinguishable from the contralateral control muscles after 150 days. At 332 days, the conduction properties of the implanted nerve confirmed that the nerve was capable of conduction through the silicon grid. Histological observations were consistent with normal peripheral nerve regeneration following microsurgical neurrorhaphy. Seven additional rabbits have been implanted and will be fully analyzed in the future. It was concluded that the silicon peripheral nerve implant described here should be pursued as a substrate for a chronic neuroelectric interface.

[1]  A. Aguayo,et al.  A QUANTITATIVE ULTRASTRUCTURAL STUDY OF REGENERATION FROM ISOLATED PROXIMAL STUMPS OF TRANSECTED UNMYELINATED NERVES1, 2, 3 , 1973, Journal of neuropathology and experimental neurology.

[2]  M. Wilson,et al.  Implantable electrode for recording nerve signals in awake animals. , 1976, Journal of applied physiology.

[3]  A. Spurr A low-viscosity epoxy resin embedding medium for electron microscopy. , 1969, Journal of ultrastructure research.

[4]  R. Stein,et al.  Principles Underlying New Methods for Chronic Neural Recording , 1975, Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques.

[5]  A. Berger,et al.  The Interfascicular Nerve-grafting of the Median and Ulnar Nerves , 1972 .

[6]  G. E. Loeb,et al.  Analysis and microelectronic design of tubular electrode arrays intended for chronic, multiple singleunit recording from captured nerve fibres , 1977, Medical and Biological Engineering and Computing.

[7]  Byron K. Lichtenberg,et al.  Distinguishability of Functionally Distinct Evoked Neuroelectric Signals on the Surface of a Nerve , 1979, IEEE Transactions on Biomedical Engineering.

[8]  D. Whitteridge,et al.  Conduction velocity and myelin thickness in regenerating nerve fibres , 1946, The Journal of physiology.

[9]  A. Marks Regenerative reconstruction of a tract in a rat's brain. , 1972, Experimental neurology.

[10]  R. Stein,et al.  Regeneration Electrode Units: Implants for Recording from Single Peripheral Nerve Fibers in Freely Moving Animals , 1974, Science.

[11]  J. Terzis,et al.  EPINEURIAL VS. PERINEURIAL REPAIR: An Ultrastructural and Electrophysiological Study of Nerve Regeneration , 1977 .

[12]  K. Bean,et al.  Anisotropic etching of silicon , 1978, IEEE Transactions on Electron Devices.