Operation margin analysis of zone 3 impedance relay based on sensitivities to power injection

Zone 3 impedance relays (mho relays) on transmission lines have an overreaching protection region. The relays are sensitive to power flow redistribution and to power swing caused by outage or switch operation outside the protected region. Traditionally, the operation margin of mho relays is expressed with impedance. Various load flow schemes that require extensive calculation are necessary to decide the optimal location to control the operation margin. The equivalent expression of the operation margin expressed by a function of bus voltage has been established, and a preventive control model based on the sensitivities of the operation margin to power injection has been proposed. On the basis of the simulation results on the IEEE 14-bus test system, it has been found that: (1) the operation margin can be effectively controlled using the sensitivity method; (2) active and reactive power controls at the same bus may yield opposite control effects; (3) the proposed method is especially effective for stressed power systems; (4) relative control error with is very small as compared to the load flow method and (5) the calculation efficiency is much higher than that of the load flow method.

[1]  W. O. Kennedy,et al.  Five years experience with a new method of field testing cross and quadrature polarized mho distance relays. I. Results and observations , 1988 .

[2]  P. Bastard,et al.  Fundamental basis for distance relaying with parametrical estimation , 2000 .

[3]  P. Kundur,et al.  Power system stability and control , 1994 .

[4]  T.S. Bi,et al.  Adaptive residual current compensation for robust fault-type selection in mho elements , 2005, IEEE Transactions on Power Delivery.

[5]  R.K. Aggarwal,et al.  An enhanced zone 3 algorithm of a distance relay using transient components and state diagram , 2004, IEEE Transactions on Power Delivery.

[6]  James S. Thorp,et al.  Anatomy of power system blackouts: preventive relaying strategies , 1996 .

[7]  K. Mustaphi,et al.  Relay setting considerations and operational experience of a long 500 kV transmission line , 1988 .

[8]  A.G. Phadke,et al.  Third zone revisited , 2006, IEEE Transactions on Power Delivery.

[9]  G. Gangadharan,et al.  Microprocessor based three step quadrilateral distance relay for the protection of EHV/UHV transmission lines , 1992 .

[10]  Craig Sayers Results and Observations , 1999 .

[11]  R. J. Marttila Effect of transmission line loading on the performance characteristics of polyphase distance relay elements , 1988 .

[12]  Jianxin Tang,et al.  Modeling of a transmission line protection relaying scheme using Petri nets , 1997 .

[13]  W. O. Kennedy,et al.  Five years experience with a new method of field testing cross and quadrature polarized mho distance relays. II. Three case studies , 1988 .

[14]  K. H. Tseng,et al.  Load Model Effects on Distance Relay Settings , 2002, IEEE Power Engineering Review.

[15]  C. Singh,et al.  A practical approach for integrated power system vulnerability analysis with protection failures , 2004, IEEE Transactions on Power Systems.

[16]  J. Pinto de Sa,et al.  A probabilistic approach to setting distance relays in transmission networks , 1996, Proceedings of 1996 Transmission and Distribution Conference and Exposition.