Detecting Open-Switch Faults: Using Asymmetric Zero-Voltage Switching States

This article presents a detection method for an open-switch fault in cascaded H-bridge multilevel inverters (CHMIs). Recently, CHMIs were widely used in high-power systems. Therefore, the reliability of this topology has become an important factor. To improve the reliability, methods for detecting openswitch faults are required. The proposed method is based on the current path analysis according to zero-voltage switching states. The location of both faulty cells and switches can be detected from the current waveform and zero-voltage switching states. This method is applicable when using the level-shifted pulsewidth modulation (LSPWM), which is commonly used for a modulation method in CHMIs. The performance of the proposed detection method is verified by simulation and experimental results.

[1]  F. Blaabjerg,et al.  Open-switch fault detection method of an NPC converter for wind turbine systems , 2013, 2013 IEEE Energy Conversion Congress and Exposition.

[2]  Haibing Hu,et al.  Comparisons of Space-Vector Modulation and Carrier-Based Modulation of Multilevel Inverter , 2008, IEEE Transactions on Power Electronics.

[3]  José R. Rodríguez,et al.  A Survey on Neutral-Point-Clamped Inverters , 2010, IEEE Transactions on Industrial Electronics.

[4]  Pan Duan,et al.  Open-switch fault diagnosis and system reconfiguration of doubly fed wind power converter used in a microgrid , 2011, IEEE Transactions on Power Electronics.

[5]  Mariusz Malinowski,et al.  A Survey on Cascaded Multilevel Inverters , 2010, IEEE Transactions on Industrial Electronics.

[6]  F. Blaabjerg,et al.  Method for Detecting an Open-Switch Fault in a Grid-Connected NPC Inverter System , 2012, IEEE Transactions on Power Electronics.

[7]  Wenhua Liu,et al.  Multilevel Optimal Modulation and Dynamic Control Strategies for STATCOMs Using Cascaded Multilevel Inverters , 2007, IEEE Transactions on Power Delivery.

[8]  Bin Wu,et al.  Level-shifted PWM for Cascaded Multilevel Inverters with Even Power Distribution , 2007, 2007 IEEE Power Electronics Specialists Conference.

[9]  Kai Ding,et al.  Analysis of an asymmetric modulation method for cascaded multilevel inverters , 2012 .

[10]  Daniel U. Campos-Delgado,et al.  Diagnosis of open-switch faults in variable speed drives by stator current analysis and pattern recognition , 2013 .

[11]  Frede Blaabjerg,et al.  Diagnosis and Tolerant Strategy of an Open-Switch Fault for T-Type Three-Level Inverter Systems , 2014, IEEE Transactions on Industry Applications.

[12]  Bin Lu,et al.  A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters , 2008, 2008 IEEE Industry Applications Society Annual Meeting.

[13]  Antonio Marcus Nogueira Lima,et al.  Fault detection of open-switch damage in voltage-fed PWM motor drive systems , 2003 .

[14]  Leon M. Tolbert,et al.  Fault Diagnosis and Reconfiguration for Multilevel Inverter Drive Using AI-Based Techniques , 2007, IEEE Transactions on Industrial Electronics.

[15]  Ji-Yoon Yoo,et al.  Practical Implementation of PWM Synchronization and Phase-Shift Method for Cascaded H-Bridge Multilevel Inverters Based on a Standard Serial Communication Protocol , 2008, IEEE Transactions on Industry Applications.

[16]  June-Seok Lee,et al.  An Open-Switch Fault Detection Method and Tolerance Controls Based on SVM in a Grid-Connected T-Type Rectifier With Unity Power Factor , 2014, IEEE Transactions on Industrial Electronics.

[17]  Brendan Peter McGrath,et al.  Multicarrier PWM strategies for multilevel inverters , 2002, IEEE Trans. Ind. Electron..

[18]  Bin Wu,et al.  Multilevel Voltage-Source-Converter Topologies for Industrial Medium-Voltage Drives , 2007, IEEE Transactions on Industrial Electronics.

[19]  June-Seok Lee,et al.  A detection method for an open-switch fault in cascaded H-bridge multilevel inverters , 2014, 2014 IEEE Energy Conversion Congress and Exposition (ECCE).

[20]  C.O. Nwankpa,et al.  A new type of STATCOM based on cascading voltage source inverters with phase-shifted unipolar SPWM , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[21]  Dong-Seok Hyun,et al.  An Improved Carrier-Based SVPWM Method Using Leg Voltage Redundancies in Generalized Cascaded , 2003 .

[22]  Fang Zheng Peng,et al.  Multilevel inverters: a survey of topologies, controls, and applications , 2002, IEEE Trans. Ind. Electron..