A Survey of Vascular Access for Hemodialysis

To analyze the current status of various techniques for vascular access in patients with chronic renal failure requiring hemodialysis, a retrospective review of 113 patients over a period of nineteen years undergoing either radiocephalic (direct) shunts or polytetra-fluoroethylene (PTFE) shunts was conducted. Accessibility rate was determined as total time of graft function until ultimate failure. Direct shunt was undergone by 93 patients (82%). Accessibility was 89% and 80% at one and five years, respectively. Twenty patients (18%) underwent PTFE shunts. Accessibility was 61% and 29% at one and five years, respectively. Thrombosis, which was the main complication accounting for graft failure, occurred earlier and more frequently in the PTFE group. Results in patients with diabetes mellitus (DM) were also significantly worse. A direct shunt at the most peripheral site is the most favorable option for vascular access for hemodialysis. Because of poorer results with PTFE, more proximal native vessels (ie, brachial artery to antecubital vein) are preferable if distal shunts are not possible.

[1]  D. Domoto,et al.  Combined aspirin and sulfinpyrazone in the prevention of recurrent hemodialysis vascular access thrombosis. , 1991, Thrombosis research.

[2]  B. Barrou,et al.  Biological Grafts for Vascular Access in Patients with End-Stage Renal Failure , 1991 .

[3]  J. Schulak,et al.  Salvage of thrombosed forearm polytetrafluoroethylene vascular access grafts by reversal of flow direction and venous bypass grafting. , 1991, American journal of surgery.

[4]  G. Kootstra,et al.  A survey of vascular access for haemodialysis in The Netherlands. , 1991, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[5]  R. Schwartz,et al.  Does the end-to-end venous anastomosis offer a functional advantage over the end-to-side venous anastomosis in high-output arteriovenous grafts? , 1990, Journal of vascular surgery.

[6]  J. Tordoir,et al.  Long-term follow-up of the polytetrafluoroethylene (PTFE) prosthesis as an arteriovenous fistula for haemodialysis. , 1988, European journal of vascular surgery.

[7]  M. V. van Gemert,et al.  Simulated hemodynamic comparison of arteriovenous fistulas. , 1987, Journal of vascular surgery.

[8]  O. Winsett,et al.  Complications of Vascular Access for Hemodialysis , 1985, Southern medical journal.

[9]  J. Elfström,et al.  What causes the failures in surgically constructed arteriovenous fistulas? , 1983, Acta chirurgica Scandinavica.

[10]  G. Sicard,et al.  Bovine carotid artery and expanded polytetrafluroethylene grafts for hemodialysis vascular access. , 1980, The Journal of surgical research.