A passive wrist with switchable stiffness for a body-powered hydraulically actuated hand prosthesis

State of art upper limb prostheses lack several degrees of freedom (DoF) and force the individuals to compensate for them by changing the motions of their arms and body. Such movements often yield to articulation injuries, nonetheless these could be prevented by adding DoFs, for instance, an articulated passive wrist. Available stiff or compliant wrists with passive flexion/extension and/or radial/ulnar deviation are sub-optimal solutions. Indeed, stiff wrists induce the individuals wearing them to perform exaggerated compensatory movements during the reaching phase while compliant wrists proved to be unpractical while manipulating heavy objects. Here we present a wrist capable of combining the benefits of stiff and compliant wrists. It is provided with two switchable levels of passive compliance that are automatically selected. The prototype was integrated in a body-powered hydraulic hand prosthesis and actuated using the same hydraulic circuit of the hand. Detailed analysis of the parameters that affect the compliance, the critical load and the performance of the prosthesis are presented.

[1]  M LeBlanc Current evaluation of hydraulics to replace the cable force transmission system for body-powered upper-limb prostheses. , 1990, Assistive technology : the official journal of RESNA.

[2]  A. Kargov,et al.  Development of a Multifunctional Cosmetic Prosthetic Hand , 2007, 2007 IEEE 10th International Conference on Rehabilitation Robotics.

[3]  Huosheng Hu,et al.  Myoelectric control systems - A survey , 2007, Biomed. Signal Process. Control..

[4]  G. Smit,et al.  Efficiency of Voluntary Closing Hand and Hook Prostheses , 2010, Prosthetics and orthotics international.

[5]  Christian Cipriani,et al.  Preliminary design and development of a two degrees of freedom passive compliant prosthetic wrist with switchable stiffness , 2013, 2013 IEEE International Conference on Robotics and Biomimetics (ROBIO).

[6]  R. M. Bongers,et al.  Flexible and static wrist units in upper limb prosthesis users: functionality scores, user satisfaction and compensatory movements , 2016, Journal of NeuroEngineering and Rehabilitation.

[7]  Peter J Kyberd The influence of passive wrist joints on the functionality of prosthetic hands , 2012, Prosthetics and orthotics international.

[8]  Edwin K. Iversen,et al.  EVALUATION STUDIES OF NEW ELECTRIC TERMINAL DEVICES , 2005 .

[9]  Branden Petersen PRELIMINARY FEEDBACK FROM FIELD TRIAL USERS OF THE MOTION CONTROL MULTI-FLEX WRIST , 2008 .

[10]  Christian Cipriani,et al.  Is it Finger or Wrist Dexterity That is Missing in Current Hand Prostheses? , 2015, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[11]  Lorena Steenbergen,et al.  Repetitive Strain Injuries in Youth , 2000, Journal of the American Academy of Nurse Practitioners.

[12]  Gerwin Smit,et al.  The Lightweight Delft Cylinder Hand: First Multi-Articulating Hand That Meets the Basic User Requirements , 2015, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[13]  Harold H. Sears,et al.  Electric Wrist Rotation in Proportional-Controlled Systems , 1998 .

[14]  Christian Cipriani,et al.  Design of Artificial Hands: A Review , 2014, The Human Hand as an Inspiration for Robot Hand Development.

[15]  M.C. Carrozza,et al.  Development of an innovative and compliant robotic wrist , 2008, 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[16]  T. Kuiken,et al.  Neural Interfaces for Control of Upper Limb Prostheses: The State of the Art and Future Possibilities , 2011, PM & R : the journal of injury, function, and rehabilitation.