Indoor air quality in low energy residential buildings in Lithuania

Abstract The indoor environment was investigated in 11 newly built low energy residential buildings. Temperature, relative humidity, the concentrations of CO 2 , NO 2 , formaldehyde, volatile organic compounds (VOC), and semi-volatile organic compounds (SVOC, i.e. PAHs, PCBs, HCB) were measured. Despite of the low air exchange rate in most buildings (0.08–0.69 h −1 ), CO 2 and many monitored VOC and SVOC concentrations were at typical indoor levels, while the concentration of formaldehyde (3.3–52.3 μg/m 3 ) was elevated above the Lithuanian limit value. In several buildings, extremely high concentrations of VOCs were observed where the installation of interior surfaces and furnishing were done shortly prior the measurement campaign. Decrease of benzene, toluene, ethylbenzene and xylene (BTEX) sum concentrations was rapid and fell below Lithuanian limit values in one month. This study demonstrates the importance of checking indoor air quality before occupancy and avoiding moving into buildings before the complete installation of the interior. Selection of low-emitting building and finishing materials, furniture, cleaning products and ensuring effective work of mechanical ventilation will contribute to good indoor air quality in low energy buildings.

[1]  D. Martuzevicius,et al.  Indoor–outdoor levels of size segregated particulate matter and mono/polycyclic aromatic hydrocarbons among urban areas using solid fuels for heating , 2014 .

[2]  R. Gale,et al.  Semivolatile organic compounds in residential air along the Arizona-Mexico border. , 2009, Environmental science & technology.

[3]  Mickael Derbez,et al.  Indoor air quality and comfort in seven newly built, energy-efficient houses in France , 2014 .

[4]  Patterns of Volatile Organic Compound Emissions in Building Structures , 2012 .

[5]  Lance Wallace,et al.  Source apportionment of indoor and outdoor volatile organic compounds at homes in Edmonton, Canada , 2015 .

[6]  S. K. Brown,et al.  Volatile organic pollutants in new and established buildings in Melbourne, Australia. , 2002, Indoor air.

[7]  Lars Barregard,et al.  The use of semipermeable membrane devices as passive samplers to determine persistent organic compounds in indoor air. , 2006, Journal of environmental monitoring : JEM.

[8]  Tunga Salthammer,et al.  Impact of building materials on indoor formaldehyde levels: Effect of ceiling tiles, mineral fiber insulation and gypsum board , 2013 .

[9]  Pentti Kalliokoski,et al.  Reference values for indoor air pollutant concentrations in new, residential buildings in Finland , 2006 .

[10]  Charles J. Weschler,et al.  Changes in indoor pollutants since the 1950s , 2009 .

[11]  Barbara Kolarik,et al.  Concentrations of Formaldehyde in new Danish Residential Buildings in Relation to WHO Recommendations and CEN Requirements , 2012 .

[12]  Dainius Martuzevicius,et al.  Assessment of indoor environmental quality in existing multi-family buildings in North-East Europe. , 2015, Environment international.

[13]  D. Martuzevicius,et al.  PAHs in Indoor and Outdoor Air from Decentralized Heating Energy Production: Comparison of Active and Passive Sampling , 2016 .

[14]  Xudong Yang,et al.  Volatile organic compounds in different interior construction stages of an apartment , 2014 .

[15]  W. Jo,et al.  Volatile organic compound concentrations, emission rates, and source apportionment in newly-built apartments at pre-occupancy stage. , 2012, Chemosphere.

[16]  Mickael Derbez,et al.  A 3-year follow-up of indoor air quality and comfort in two energy-efficient houses , 2014 .

[17]  Alan Meier,et al.  Rating the energy performance of buildings , 2004 .

[18]  C. Weschler Chemistry in indoor environments: 20 years of research. , 2011, Indoor air.

[19]  G. Bekö,et al.  Indoor air quality in the Swedish housing stock and its dependence on building characteristics , 2013 .

[20]  A T Hodgson,et al.  Volatile organic compound concentrations and emission rates in new manufactured and site-built houses. , 2000, Indoor air.

[21]  L. Larsson,et al.  Influence of relative humidity on VOC concentrations in indoor air , 2015, Environmental Science and Pollution Research.

[22]  N. Glasser,et al.  Concentrations and determinants of gaseous aldehydes in 162 homes in Strasbourg (France) , 2008 .

[23]  P. Engelmann,et al.  Comfort, Indoor Air Quality, and Energy Consumption in Low Energy Homes , 2013 .

[24]  Steffen Loft,et al.  Personal exposure to PM2.5, black smoke and NO2 in Copenhagen: relationship to bedroom and outdoor concentrations covering seasonal variation , 2005, Journal of Exposure Analysis and Environmental Epidemiology.

[25]  Gabriel Bekö,et al.  Indoor air quality in passive and conventional new houses in Sweden , 2015 .