Ultrasensitive and selective non-enzymatic glucose detection using copper nanowires.

In the pursuit of more economical electrocatalysts for non-enzymatic glucose sensors, one-dimensional Cu nanowires (Cu NWs) with uniform size distribution and a large aspect ratio (>200) were synthesized by a facile, scalable, wet-chemistry approach. The morphology, crystallinity, and surface property of the as-prepared Cu NWs were examined by SEM, XRD, and XPS, respectively. The electrochemical property of Cu NWs for glucose electrooxidation was thoroughly investigated by cyclic voltammetry. In the amperometric detection of glucose, the Cu NWs modified glassy carbon electrode exhibited an extraordinary limit of detection as low as 35 nM and a wide dynamic range with excellent sensitivity of 420.3 μA cm(-2) mM(-1), which was more than 10,000 times higher than that of the control electrode without Cu NWs. The performance of the developed glucose sensor was also independent to oxygen concentration and free from chloride poisoning. Furthermore, the interference from uric acid, ascorbic acid, acetaminophen, fructose, and sucrose at the level of their physiological concentration were insignificant, indicating excellent selectivity. Finally, good accuracy and high precision for the quantification of glucose concentration in human serum samples implicate the applicability of Cu NWs in sensitive and selective non-enzymatic glucose detection.

[1]  Sejin Park,et al.  Nonenzymatic glucose detection using mesoporous platinum. , 2003, Analytical chemistry.

[2]  H. Zeng,et al.  Large-scale synthesis of high-quality ultralong copper nanowires. , 2005, Langmuir : the ACS journal of surfaces and colloids.

[3]  T. Edwards,et al.  Lithographically defined 3D nanoporous nonenzymatic glucose sensors. , 2011, Biosensors & bioelectronics.

[4]  John H. T. Luong,et al.  Electrochemical detection of carbohydrates using copper nanoparticles and carbon nanotubes , 2004 .

[5]  Jeunghee Park,et al.  In-situ growth of copper sulfide nanocrystals on multiwalled carbon nanotubes and their application as novel solar cell and amperometric glucose sensor materials. , 2007, Nano letters.

[6]  Changjun Hou,et al.  Microbial biosensors: a review. , 2011, Biosensors & bioelectronics.

[7]  J. Luong,et al.  Electrochemical biosensing platforms using platinum nanoparticles and carbon nanotubes. , 2004, Analytical chemistry.

[8]  Benjamin J Wiley,et al.  The Growth Mechanism of Copper Nanowires and Their Properties in Flexible, Transparent Conducting Films , 2010, Advanced materials.

[9]  Hui Zhang,et al.  Nonenzymatic electrochemical detection of glucose based on palladium-single-walled carbon nanotube hybrid nanostructures. , 2009, Analytical chemistry.

[10]  Theodore Kuwana,et al.  Electrochemical characterization of carbohydrate oxidation at copper electrodes , 1992 .

[11]  K. El-Khatib,et al.  Development of Cu2O/Carbon Vulcan XC-72 as non-enzymatic sensor for glucose determination. , 2011 .

[12]  Joseph Wang Electrochemical glucose biosensors. , 2008, Chemical reviews.

[13]  D. J. Harrison,et al.  In vitro and in vivo performance and lifetime of perfluorinated ionomer-coated glucose sensors after high-temperature curing. , 1994, Analytical chemistry.

[14]  Y. Lian,et al.  Nonenzymatic Electrochemical Glucose Sensor Based on Novel Copper Film , 2011 .

[15]  Aicheng Chen,et al.  Nonenzymatic electrochemical glucose sensor based on nanoporous PtPb networks. , 2008, Analytical chemistry.

[16]  Yu Lei,et al.  Electrospun Co3O4 nanofibers for sensitive and selective glucose detection. , 2010, Biosensors & bioelectronics.

[17]  Y. Lei,et al.  Preparation and characterization of NiO–Ag nanofibers, NiO nanofibers, and porous Ag: towards the development of a highly sensitive and selective non-enzymatic glucose sensor , 2010 .

[18]  L. C. Clark,et al.  ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY , 1962 .

[19]  Liaochuan Jiang,et al.  A highly sensitive nonenzymatic glucose sensor based on CuO nanoparticles-modified carbon nanotube electrode. , 2010, Biosensors & bioelectronics.

[20]  S. J. Yao,et al.  Anodic Oxidation of Carbohydrates and their Derivatives in Neutral Saline Solution , 1969, Nature.

[21]  Dan Xiao,et al.  An improved sensitivity non-enzymatic glucose sensor based on a CuO nanowire modified Cu electrode. , 2008, The Analyst.

[22]  Younan Xia,et al.  One‐Dimensional Nanostructures: Synthesis, Characterization, and Applications , 2003 .

[23]  Xin Li,et al.  Three-dimensional network films of electrospun copper oxide nanofibers for glucose determination. , 2009, Biosensors & bioelectronics.

[24]  H. Akanuma,et al.  Increased fructose concentrations in blood and urine in patients with diabetes. , 2002, Diabetes care.

[25]  Ashok Mulchandani,et al.  Nanowire‐Based Electrochemical Biosensors , 2006 .

[26]  Richard P. Baldwin,et al.  Constant potential amperometric detection at a copper-based electrode: electrode formation and operation , 1990 .

[27]  B. Vinet,et al.  Automated enzymatic assay for the determination of sucrose in serum and urine and its use as a marker of gastric damage. , 1998, Clinical chemistry.

[28]  Wenzhao Jia,et al.  Facile Synthesis of a Platinum Nanoflower Monolayer on a Single-Walled Carbon Nanotube Membrane and Its Application in Glucose Detection , 2010 .

[29]  A. Turner,et al.  Home blood glucose biosensors: a commercial perspective. , 2005, Biosensors & bioelectronics.

[30]  Yan Li,et al.  In situ growth of copper nanoparticles on multiwalled carbon nanotubes and their application as non-enzymatic glucose sensor materials , 2010 .

[31]  Sundaram Gunasekaran,et al.  An amperometric non-enzymatic glucose sensor by electrodepositing copper nanocubes onto vertically well-aligned multi-walled carbon nanotube arrays. , 2010, Biosensors & bioelectronics.

[32]  B. Jena,et al.  Enzyme-free amperometric sensing of glucose by using gold nanoparticles. , 2006, Chemistry.

[33]  Kang Wang,et al.  Highly Ordered Platinum‐Nanotubule Arrays for Amperometric Glucose Sensing , 2005 .

[34]  Yu Lei,et al.  CuO Nanospheres Based Nonenzymatic Glucose Sensor , 2008 .

[35]  Sejin Park,et al.  Electrochemical non-enzymatic glucose sensors. , 2006, Analytica chimica acta.

[36]  Xiangyu Lv,et al.  An improved sensitivity nonenzymatic glucose biosensor based on a CuxO modified electrode. , 2010, Biosensors & bioelectronics.

[37]  Zelin Li,et al.  Nonenzymatic amperometric response of glucose on a nanoporous gold film electrode fabricated by a rapid and simple electrochemical method. , 2011, Biosensors & bioelectronics.

[38]  Kaiming Liao,et al.  Porous cuprous oxide microcubes for non-enzymatic amperometric hydrogen peroxide and glucose sensing , 2009 .

[39]  Adam Heller,et al.  Electrochemical glucose sensors and their applications in diabetes management. , 2008, Chemical reviews.