Planar biaxial behavior of fibrin-based tissue-engineered heart valve leaflets.

To design more effective tissue-engineered heart valve replacements, the replacement tissue may need to mimic the biaxial stress-strain behavior of native heart valve tissue. This study characterized the planar biaxial properties of tissue-engineered valve leaflets and native aortic valve leaflets. Fibrin-based valve equivalent (VE) and porcine aortic valve (PAV) leaflets were subjected to incremental biaxial stress relaxation testing, during which fiber alignments were measured, over a range of strain ratios. Results showed that VE leaflets exhibited a modulus and fiber reorientation behavior that correlated with strain ratio. In contrast, PAV leaflets maintained their relaxed modulus and fiber alignment when exposed to nonequibiaxial strain, but exhibited changes in stress relaxation. In uniaxial and equi-biaxial tension, there were few observed differences in relaxation behavior between VE and PAV leaflets, despite differences in the modulus and fiber reorientation. Likewise, in both tissues there was similar relaxation response in the circumferential and radial directions in biaxial tension, despite different moduli in these two directions. This study presents some fundamental differences in the mechanical response to biaxial tension of fibrin-based tissue-engineered constructs and native valve tissue. It also highlights the importance of using a range of strain ratios when generating mechanical property data for valvular and engineered tissues. The data presented on the stress-strain, relaxation, and fiber reorientation of VE tissue will be useful in future efforts to mathematically model and improve fibrin-based tissue-engineered constructs.

[1]  R T Tranquillo,et al.  Alignment maps of tissues: II. Fast harmonic analysis for imaging. , 2001, Biophysical journal.

[2]  Karyn S Kunzelman,et al.  A coupled fluid-structure finite element model of the aortic valve and root. , 2003, The Journal of heart valve disease.

[3]  H. Alexander,et al.  Development and characterization of tissue-engineered aortic valves. , 2001, Tissue engineering.

[4]  A. Yoganathan,et al.  Planar Biaxial Creep and Stress Relaxation of the Mitral Valve Anterior Leaflet , 2006, Annals of Biomedical Engineering.

[5]  J D Humphrey,et al.  Quantification of strains in biaxially tested soft tissues. , 1987, Journal of biomechanics.

[6]  Michael S Sacks,et al.  Stability and function of glycosaminoglycans in porcine bioprosthetic heart valves. , 2006, Biomaterials.

[7]  M. Thubrikar,et al.  Comparison of the in vivo and in vitro mechanical properties of aortic valve leaflets. , 1986, The Journal of thoracic and cardiovascular surgery.

[8]  I. Vesely,et al.  Mechanical testing of cryopreserved aortic allografts. Comparison with xenografts and fresh tissue. , 1990, The Journal of thoracic and cardiovascular surgery.

[9]  Wei Sun,et al.  Effects of boundary conditions on the estimation of the planar biaxial mechanical properties of soft tissues. , 2005, Journal of biomechanical engineering.

[10]  S. Waldman,et al.  Effect of sample geometry on the apparent biaxial mechanical behaviour of planar connective tissues. , 2005, Biomaterials.

[11]  Michael S Sacks,et al.  Experimentally tractable, pseudo-elastic constitutive law for biomembranes: II. Application. , 2003, Journal of biomechanical engineering.

[12]  Y Lanir,et al.  Optimal design of biaxial tests for structural material characterization of flat tissues. , 1996, Journal of biomechanical engineering.

[13]  M. M. Adamczyk,et al.  Biaxial strain distributions in explanted porcine bioprosthetic valves. , 2002, The Journal of heart valve disease.

[14]  J E Mayer,et al.  Evaluation of biodegradable, three-dimensional matrices for tissue engineering of heart valves. , 2000, ASAIO journal.

[15]  B J Messmer,et al.  Tissue engineering: complete autologous valve conduit--a new moulding technique. , 2001, The Thoracic and cardiovascular surgeon.

[16]  M. Sacks,et al.  A method to quantify the fiber kinematics of planar tissues under biaxial stretch. , 1997, Journal of biomechanics.

[17]  C K Breuer,et al.  Tissue engineering heart valves: valve leaflet replacement study in a lamb model. , 1995, The Annals of thoracic surgery.

[18]  Victor H. Barocas,et al.  Functional Tissue-Engineered Valves from Cell-Remodeled Fibrin with Commissural Alignment of Cell-Produced Collagen , 2008 .

[19]  M. M. Adamczyk,et al.  Biaxial strain properties of elastase-digested porcine aortic valves. , 2000, The Journal of heart valve disease.

[20]  M. Sacks,et al.  A method for planar biaxial mechanical testing that includes in-plane shear. , 1999, Journal of biomechanical engineering.

[21]  Thomas F. Coleman,et al.  An Interior Trust Region Approach for Nonlinear Minimization Subject to Bounds , 1993, SIAM J. Optim..

[22]  M. Sacks,et al.  Biaxial mechanical properties of the native and glutaraldehyde-treated aortic valve cusp: Part II--A structural constitutive model. , 2000, Journal of biomechanical engineering.

[23]  Lin Yang,et al.  The relation between collagen fibril kinematics and mechanical properties in the mitral valve anterior leaflet. , 2007, Journal of biomechanical engineering.

[24]  Marcel C M Rutten,et al.  Autologous Human Tissue-Engineered Heart Valves: Prospects for Systemic Application , 2006, Circulation.

[25]  Nicholas I. Fisher,et al.  Statistical Analysis of Circular Data , 1993 .

[26]  M. Sacks,et al.  Effects of fixation pressure on the biaxial mechanical behavior of porcine bioprosthetic heart valves with long-term cyclic loading. , 2002, Biomaterials.

[27]  M. Sacks,et al.  Time-dependent biaxial mechanical behavior of the aortic heart valve leaflet. , 2007, Journal of biomechanics.

[28]  M. Sacks,et al.  Biaxial mechanical properties of the natural and glutaraldehyde treated aortic valve cusp--Part I: Experimental results. , 2000, Journal of biomechanical engineering.

[29]  R. E. Clark,et al.  Stress-strain characteristics of fresh and frozen human aortic and mitral leaflets and chordae tendineae. Implications for clinical use. , 1973, The Journal of thoracic and cardiovascular surgery.

[30]  M. Sacks,et al.  Passive biaxial mechanical properties of the rat bladder wall after spinal cord injury. , 2002, The Journal of urology.

[31]  A. Yoganathan,et al.  Biaixal Stress–Stretch Behavior of the Mitral Valve Anterior Leaflet at Physiologic Strain Rates , 2006, Annals of Biomedical Engineering.

[32]  N. Ratliff,et al.  Loss of chondroitin 6-sulfate and hyaluronan from failed porcine bioprosthetic valves. , 2003, Journal of biomedical materials research. Part A.

[33]  Frank P T Baaijens,et al.  Improved prediction of the collagen fiber architecture in the aortic heart valve. , 2005, Journal of biomechanical engineering.

[34]  A A Sauren,et al.  Elastic and viscoelastic material behaviour of fresh and glutaraldehyde-treated porcine aortic valve tissue. , 1983, Journal of biomechanics.

[35]  M. Sacks,et al.  The biomechanical effects of fatigue on the porcine bioprosthetic heart valve. , 2001, Journal of long-term effects of medical implants.

[36]  A A Sauren,et al.  The mechanical properties of porcine aortic valve tissues. , 1983, Journal of biomechanics.

[37]  Theodore T. Tower,et al.  Fiber Alignment Imaging During Mechanical Testing of Soft Tissues , 2002, Annals of Biomedical Engineering.

[38]  Kanti V. Mardia,et al.  Statistics of Directional Data , 1972 .

[39]  G. G. Peters,et al.  A two-dimensional fluid–structure interaction model of the aortic value , 2000 .

[40]  I Vesely,et al.  The role of elastin in aortic valve mechanics. , 1997, Journal of biomechanics.