Evaluation of a Marker Clip System in Sonographically Guided Core Needle Biopsy for Breast Cancer Localization Before and After Neoadjuvant Chemotherapy

Abstract Introduction The placement of intramammary marker clips has proven to be helpful for tumor localization in patients undergoing neoadjuvant chemotherapy and breast-conserving surgery. The purpose of our study was to investigate the feasibility of using a clip marker system for breast cancer localization and its influence on the imaging assessment of treatment responses after neoadjuvant chemotherapy. Patients and Methods Between March and June 2015, a total of 25 patients (n = 25), with a suspicion of invasive breast cancer with diameters of at least 2 cm (cT2), underwent preoperative sonographically guided core needle biopsy using a single-use breast biopsy system (HistoCore™) and intramammary clip marking using a directly adapted clip system based on the established O-Twist Marker™, before their scheduled preoperative neoadjuvant chemotherapy. Localization of the intramammary marker clip was controlled by sonography and digital breast tomosynthesis. Results Sonography detected no dislocation of intrammammary marker clips in 20 of 25 patients (80 %), while digital breast tomosynthesis showed accurate placement without dislocation in 24 patients (96 %) (p < 0.05). There was no evidence of significant clip migration during preoperative follow-up imaging after neoadjuvant chemotherapy. No complication related to the clip marking was noted and there was no difficulty in evaluating the treatment response to neoadjuvant chemotherapy. Among the breast-conserving surgeries performed, no cases were identified in which intraoperative loss of the marker clip had occurred. Conclusion Our study underscores the importance of intramammary marking clip systems before neoadjuvant chemotherapy. Placement of marker clips is advised to facilitate accurate tumor bed localization. With regard to digital breast tomosynthesis, its development continues to improve the quality of diagnostics and the therapy of breast cancer particularly for small breast cancer tumors or in neoadjuvant chemotherapy setting.

[1]  S. Kook,et al.  Ultrasonography-Guided Surgical Clip Placement for Tumor Localization in Patients Undergoing Neoadjuvant Chemotherapy for Breast Cancer , 2015, Journal of breast cancer.

[2]  M. Bani,et al.  Comparison of Sonography versus Digital Breast Tomosynthesis to Locate Intramammary Marker Clips. , 2015, Geburtshilfe und Frauenheilkunde.

[3]  K. Hunt,et al.  Tumor Biology Correlates With Rates of Breast-Conserving Surgery and Pathologic Complete Response After Neoadjuvant Chemotherapy for Breast Cancer: Findings From the ACOSOG Z1071 (Alliance) Prospective Multicenter Clinical Trial , 2014, Annals of surgery.

[4]  Gideon Blumenthal,et al.  Pathological complete response and long-term clinical benefit in breast cancer: the CTNeoBC pooled analysis , 2014, The Lancet.

[5]  M. Bani,et al.  Evaluation of Newly Adapted Clip Marker System in Ultrasound-Guided Core Needle Biopsy for Suspicion of Breast Cancer. , 2013, Geburtshilfe und Frauenheilkunde.

[6]  Per Skaane,et al.  Overview of the evidence on digital breast tomosynthesis in breast cancer detection. , 2013, Breast.

[7]  R. Schulz-Wendtland Neoadjuvant chemotherapy--monitoring: clinical examination, ultrasound, mammography, MRI, elastography: only one, only few or all? , 2012, European journal of radiology.

[8]  P. Fasching,et al.  Definition and impact of pathologic complete response on prognosis after neoadjuvant chemotherapy in various intrinsic breast cancer subtypes. , 2012, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[9]  A. Tutt,et al.  Recommendations from an International Consensus Conference on the Current Status and Future of Neoadjuvant Systemic Therapy in Primary Breast Cancer , 2012, Annals of Surgical Oncology.

[10]  M. Bani,et al.  HistoCore® - A New Single-use Breast Biopsy System of the Next Generation in Daily Clinical Routine , 2010 .

[11]  E. Wenkel,et al.  Quo vadis? Trends in Digital Mammography , 2009 .

[12]  L. Schwartz,et al.  New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1). , 2009, European journal of cancer.

[13]  R Schulz-Wendtland,et al.  [Current situation and future perspectives of digital mammography]. , 2008, Der Radiologe.

[14]  W. Woodward,et al.  Placement of radiopaque clips for tumor localization in patients undergoing neoadjuvant chemotherapy and breast conservation therapy , 2007, Cancer.

[15]  C Böhner,et al.  Experimental Phantom Lesion Detectability Study Using a Digital Breast Tomosynthesis Prototype System , 2006, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[16]  Norman Wolmark,et al.  Sequential preoperative or postoperative docetaxel added to preoperative doxorubicin plus cyclophosphamide for operable breast cancer:National Surgical Adjuvant Breast and Bowel Project Protocol B-27. , 2006, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[17]  J. Ioannidis,et al.  Neoadjuvant versus adjuvant systemic treatment in breast cancer: a meta-analysis. , 2005, Journal of the National Cancer Institute.

[18]  H. Sittek,et al.  [O-twist marker for post-interventional marking in imaging of suspected breast lesions]. , 2005, Der Radiologe.

[19]  M. Cura,et al.  Recognizing pitfalls in early and late migration of clip markers after imaging-guided directional vacuum-assisted biopsy. , 2004, Radiographics : a review publication of the Radiological Society of North America, Inc.

[20]  E. Wenkel,et al.  [Do tissue marker clips after sonographically or stereotactically guided breast biopsy improve follow-up of small breast lesions and localisation of breast cancer after chemotherapy?]. , 2002, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[21]  R. J. Brenner Percutaneous removal of postbiopsy marking clip in the breast using stereotactic technique. , 2001, AJR. American journal of roentgenology.

[22]  E. Rosen,et al.  Metallic clip deployment during stereotactic breast biopsy: retrospective analysis. , 2001, Radiology.

[23]  T. Pope,et al.  Sonographically guided clip placement facilitates localization of breast cancer after neoadjuvant chemotherapy. , 2000, AJR. American journal of roentgenology.

[24]  N. Dash,et al.  Usefulness of tissue marker clips in patients undergoing neoadjuvant chemotherapy for breast cancer. , 1999, AJR. American journal of roentgenology.

[25]  F. Burbank,et al.  Tissue marking clip for stereotactic breast biopsy: initial placement accuracy, long-term stability, and usefulness as a guide for wire localization. , 1997, Radiology.

[26]  L. Liberman,et al.  Clip placement after stereotactic vacuum-assisted breast biopsy. , 1997, Radiology.

[27]  D. Wickerham,et al.  Effect of preoperative chemotherapy on local-regional disease in women with operable breast cancer: findings from National Surgical Adjuvant Breast and Bowel Project B-18. , 1997, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.