Compact high-resolution gamma-ray computed tomography system for multiphase flow studies.

In this paper, a compact high-resolution gamma-ray Computed Tomography (CompaCT) measurement system for multiphase flow studies and tomographic imaging of technical objects is presented. Its compact and robust design makes it particularly suitable for studies on industrial facilities and outdoor applications. Special care has been given to thermal ruggedness, shock resistance, and radiation protection. Main components of the system are a collimated (137)Cs isotopic source, a thermally stabilised modular high-resolution gamma-ray detector arc with 112 scintillation detector elements, and a transportable rotary unit. The CompaCT allows full CT scans of objects with a diameter of up to 130 mm and can be operated with any tilting angle from 0° (horizontal) to 90° (vertical).

[1]  Uwe Hampel,et al.  Liquid flow texture analysis in trickle bed reactors using high-resolution gamma ray tomography , 2008 .

[2]  Timothy J. O'Hern,et al.  Gamma-densitometry tomography of gas holdup spatial distribution in industrial-scale bubble columns , 1995 .

[3]  Uwe Hampel,et al.  Design of a modular signal processing board (MSPB) for gamma-ray imaging applications , 2012 .

[4]  Uwe Hampel,et al.  Time resolving gamma-tomography for periodically changing gas fraction fields and its application to an axial pump , 2003 .

[5]  Jyeshtharaj B. Joshi,et al.  Gas hold-up profiles in foaming liquids in bubble columns , 2001 .

[6]  Uwe Hampel,et al.  Measurement of Fluid Distributions in a Rotating Fluid Coupling Using High Resolution Gamma Ray Tomography , 2008 .

[7]  F. A. Kulacki,et al.  Design of an Isotopic CT Scanner for Two Phase Flow Measurements , 1980, IEEE Transactions on Nuclear Science.

[8]  Uwe Hampel,et al.  Measurement of Liquid Distributions in Particle Packings Using Wire-Mesh Sensor versus Transmission Tomographic Imaging , 2010 .

[9]  Uwe Hampel,et al.  Void measurement using high-resolution gamma-ray computed tomography , 2011 .

[10]  Dominique Toye,et al.  Imaging of liquid distribution in reactive distillation packings with a new high-energy x-ray tomograph , 2005 .

[11]  Christophe Boyer,et al.  Measurement of liquid flow distribution in trickle bed reactor of large diameter with a new gamma-ray tomographic system , 2002 .

[12]  R. F. Mudde,et al.  Time-Resolved γ-Densitometry Imaging within Fluidized Beds , 2005 .

[13]  U. Hampel,et al.  An ultra fast electron beam x-ray tomography scanner , 2008 .

[14]  Eckhard Krepper,et al.  CFD modelling of subcooled boiling—Concept, validation and application to fuel assembly design , 2007 .

[15]  Uwe Hampel,et al.  Tomography measurements of gas holdup in rotating foam reactors with Newtonian, non-Newtonian and foaming liquid , 2011 .

[16]  Uwe Hampel,et al.  Advanced Tomographic Techniques for Flow Imaging in Columns with Flow Distribution Packings , 2011 .

[17]  Anastasios J. Karabelas,et al.  Liquid distribution in horizontal axially rotated packed beds , 1993 .

[18]  F. Zimmermann,et al.  High resolution gamma ray tomography scanner for flow measurement and non-destructive testing applications. , 2007, The Review of scientific instruments.

[19]  Uwe Hampel,et al.  Temperature control design for a high-resolution gamma-ray tomography detector. , 2010, The Review of scientific instruments.

[20]  Sailesh Kumar,et al.  A γ-ray tomographic scanner for imaging voidage distribution in two-phase flow systems , 1995 .

[21]  G. Herman,et al.  Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography. , 1970, Journal of theoretical biology.

[22]  S. Kamata,et al.  High energy X-ray computed tomography for industrial applications , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[23]  Patrick L. Mills,et al.  Multiphase catalytic reactors: a perspective on current knowledge and future trends , 2002 .

[24]  Uwe Hampel,et al.  Design of a high-resolution gamma-ray detector module for tomography applications , 2007 .

[25]  B. T. Hjertaker,et al.  A dual sensor flow imaging tomographic system , 1996 .

[26]  Uwe Hampel,et al.  Application of high-resolution gamma ray tomography to the measurement of gas hold-up distributions in a stirred chemical reactor , 2007 .

[27]  Uwe Hampel,et al.  Application of gamma tomography to the measurement of fluid distributions in a hydrodynamic coupling , 2005 .