The Gray-level Co-occurrence Matrix Approach to Measure Uniformity of Fuji Prescale Pressure Sensitive Film Samples

Fuji scaled pressure sensitive films (FPPSF) are used in many sciences, especially for mechanical-based measurements. Since these films are paper-based sensors, the measurement values are mostly found manually after a series of processing according to the ambient conditions. The accuracy of the measurement results depends on the calibration process. However, there is no determination method regarding the accuracy of these processes in the literature. The aim of this study is to point out the subjects that may affect the accuracy, especially during the experimental calibration and to recommend a new method in order to evaluate the homogeneity in particular. To evaluate the homogeneity of the calibration data produced for this purpose, the gray level co-occurrence matrix (GLCM) was used and statistically compared with the relevant calibration curves presented in the current literature. As a result, the energy property parameter of GLCM was found to be applicable to control the image smoothness of the samples to realize the accuracy of the generated curve.

[1]  C. Delman,et al.  The Biomechanical Effects of Simulated Radioscapholunate Fusion with Distal Scaphoidectomy, 4-Corner Fusion with Complete Scaphoidectomy, and Proximal Row Carpectomy Compared to the Native Wrist. , 2021, The Journal of hand surgery.

[2]  Aimee Bobko,et al.  Effects of implant rotational malposition on contact surface area after implantation of the augmented glenoid baseplate in the setting of glenoid bone loss , 2021, International Orthopaedics.

[3]  Y. Açil,et al.  Six-year clinical outcomes of implant-supported acrylic vs. ceramic superstructures according to the All-on-4 treatment concept for the rehabilitation of the edentulous maxilla , 2021, Odontology.

[4]  Yingzhi Gu,et al.  Bite Force Transducers and Measurement Devices , 2021, Frontiers in Bioengineering and Biotechnology.

[5]  K. Matsuo,et al.  Relationship between two pressure-sensitive films for testing reduced occlusal force in diagnostic criteria for oral hypofunction. , 2021, Gerodontology.

[6]  T. Lim,et al.  Occlusal force and occlusal contact reestablishment with resin-bonded fixed partial dental prostheses using the Dahl concept: A clinical study. , 2021, The Journal of prosthetic dentistry.

[7]  H. Jang,et al.  The effect of the mechanical property and size of the surface contacts of the brake lining on friction instability , 2021 .

[8]  Yasin Kisioglu,et al.  Evaluation of contact characteristics of a patient-specific artificial dysplastic hip joint. , 2014, Acta of bioengineering and biomechanics.

[9]  I. Mutlu,et al.  Higher order regression functions result better fit for the calibration curve , 2013, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[10]  Christopher D Harner,et al.  Characterization of the performance of a custom program for image processing of pressure sensitive film. , 2009, Journal of Biomechanical Engineering.

[11]  V. Goel,et al.  Scaphoid Excision with Four-Corner Fusion: A Biomechanical Study , 2007, Hand.

[12]  Chao-Sung Lin,et al.  Simulation and experimentation on the contact width and pressure distribution of lip seals , 2006 .

[13]  David Cebon,et al.  Effects of tyre contact pressure distribution on the deformation rates of pavements , 2006 .

[14]  Kent N Bachus,et al.  Measuring contact area, force, and pressure for bioengineering applications: using Fuji Film and TekScan systems. , 2006, Medical engineering & physics.

[15]  Huajiang Ouyang,et al.  Brake Pad Surface Topography Part I: Contact Pressure Distribution , 2005 .

[16]  J. Alonso,et al.  Contact pressures in the flexed hip joint during lateral trochanteric loading , 2005, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[17]  Glenn F. Cada,et al.  Use of Pressure-Sensitive Film to Quantify Sources of Injury to Fish , 2005 .

[18]  Francesco Aymerich,et al.  Evaluation of nominal contact area and contact pressure distribution in a steel-steel interface by means of ultrasonic techniques , 2003 .

[19]  Jiann-Jong Liau,et al.  The influence of surgical malalignment on the contact pressures of fixed and mobile bearing knee prostheses--a biomechanical study. , 2003, Clinical biomechanics.

[20]  V K Goel,et al.  Experimental validation of a finite element model of the temporomandibular joint. , 2001, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[21]  J. L. Thomas,et al.  The effects on subtalar contact and pressure following talonavicular and midtarsal joint arthrodesis. , 2000, The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons.

[22]  A. Liggins Calibration and manipulation of data from Fuji pressure-sensitive film , 2000 .

[23]  M. Harris,et al.  An improved method for measuring tibiofemoral contact areas in total knee arthroplasty: a comparison of K-scan sensor and Fuji film. , 1999, Journal of biomechanics.

[24]  N. Sharkey,et al.  The Role of the Acetabular Labrum and the Transverse Acetabular Ligament in Load Transmission in the Hip* , 1998, The Journal of bone and joint surgery. American volume.

[25]  M. Hull,et al.  The effect of intersegmental knee moments on patellofemoral contact mechanics in cycling. , 1998, Journal of biomechanics.

[26]  C. Caldwell,et al.  The influence of screw torque, object radius of curvature, mode of bone plate application and bone plate design on bone-plate interface mechanics. , 1998, Injury.

[27]  A. Liggins,et al.  Image-averaging in the analysis of data from pressure-sensitive film , 1997 .

[28]  W. Herzog,et al.  Appropriateness of plane pressure-sensitive film calibration for contact stress measurements in articular joints. , 1996, Clinical biomechanics.

[29]  N. Sharkey,et al.  Biomechanical consequences of fracture and repair of the posterior wall of the acetabulum. , 1995, The Journal of bone and joint surgery. American volume.

[30]  J. B. Finlay,et al.  The spatial and pressure resolution of fuji pressure-sensitive film , 1995 .

[31]  K. Surry,et al.  Sealing Fuji Prescale pressure sensitive film for protection against fluid damage: the effect on its response , 1995 .

[32]  T K Liu,et al.  Contact areas and pressure distributions in the subtalar joint. , 1995, Journal of biomechanics.

[33]  S. Balter Fundamental properties of digital images. , 1993, Radiographics : a review publication of the Radiological Society of North America, Inc.

[34]  Thomas D. Brown,et al.  Quantitation of pressure-sensitive film using digital image scanning , 1987 .

[35]  Robert M. Haralick,et al.  Textural Features for Image Classification , 1973, IEEE Trans. Syst. Man Cybern..