A phase-contrast X-ray imaging system—with a 60×30 mm field of view—based on a skew-symmetric two-crystal X-ray interferometer

Abstract A phase-contrast X-ray imaging system—with a 60×30 mm field of view—for biomedical observations was developed. To extend the observation field of view, the system is fitted with a skew-symmetric two-crystal X-ray interferometer. To attain the required sub-nanoradian mechanical stability between the crystal blocks for precise operation, the interferometer was mounted on two extremely rigid positioning tables (one with a sleeve bearings) and was controlled by a feedback positioning system using phase-lock interferometry. The imaging system produced a 60×30 mm interference pattern with 60% visibility using 17.7 keV monochromatic synchrotron X-rays at the Photon Factory. It was then used to perform radiographic observation (i.e., phase mapping) of rat liver vessels. These results indicate that this imaging system can be used to perform observations of large and in vivo biological samples.

[1]  Richard J. Fitzgerald,et al.  Phase‐Sensitive X‐Ray Imaging , 2000 .

[2]  A. Momose,et al.  Phase-contrast radiographs of nonstained rat cerebellar specimen. , 1995, Medical physics.

[3]  F Busch,et al.  X-ray microtomography (microCT) using phase contrast for the investigation of organic matter. , 1997, Journal of computer assisted tomography.

[4]  Atsushi Momose,et al.  Demonstration of phase-contrast X-ray computed tomography using an X-ray interferometer , 1995 .

[5]  Atsushi Momose,et al.  Vessel Imaging by Interferometric Phase-Contrast X-Ray Technique , 2002, Circulation.

[6]  Atsushi Momose,et al.  Phase–contrast X–ray computed tomography for observing biological soft tissues , 1996, Nature Medicine.

[7]  Atsushi Momose,et al.  Wide-area phase-contrast X-ray imaging using large X-ray interferometers , 2001 .

[8]  T Takeda,et al.  Human carcinoma: early experience with phase-contrast X-ray CT with synchrotron radiation--comparative specimen study with optical microscopy. , 2000, Radiology.

[9]  T Takeda,et al.  Phase-contrast imaging with synchrotron X-rays for detecting cancer lesions. , 1995, Academic radiology.

[10]  U. Bonse,et al.  AN X‐RAY INTERFEROMETER , 1965 .

[11]  U. Bonse,et al.  The skew-symmetric two-crystal X-ray interferometer , 1974 .

[12]  Atsushi Momose,et al.  Large-area phase-contrast X-ray imaging using a two-crystal X-ray interferometer. , 2002, Journal of synchrotron radiation.

[13]  A. Momose,et al.  Operation of a Two-Crystal X-ray Interferometer at the Photon Factory. , 1997, Journal of synchrotron radiation.

[14]  Atsushi Momose,et al.  Operation of a separated-type x-ray interferometer for phase-contrast x-ray imaging , 1999 .