In-plane wavevector distribution in partially coherent X-ray propagation.

The MOI (Mutual Optical Intensity) code for propagating partially coherent radiation through beamline optics is updated by including the in-plane wavevector in the wavefield calculation. The in-plane wavevector is a local function and accurately describes the average phase distribution in a partially coherent wavefield. The improved MOI code is demonstrated by beam propagation through free space and non-ideal mirrors. The improved MOI code can provide more accurate results with lower numbers of elements, and thus has a higher calculation efficiency. Knowledge of the in-plane wavevector also enables detailed studies of wavefield information under different coherence conditions. The improved MOI code is available at http://www.moixray.cn.

[1]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[2]  Gerhard Grübel,et al.  X-ray spectroscopy: Revealing the atomic dance. , 2009, Nature materials.

[3]  Stefan Eisebitt,et al.  High-resolution magnetic-domain imaging by Fourier transform holography at 21 nm wavelength , 2013 .

[4]  P. H. Cittert,et al.  Die Wahrscheinliche Schwingungsverteilung in Einer von Einer Lichtquelle Direkt Oder Mittels Einer Linse Beleuchteten Ebene , 1934 .

[5]  Xianbo Shi,et al.  A hybrid method for X-ray optics simulation: combining geometric ray-tracing and wavefront propagation , 2014, Journal of synchrotron radiation.

[6]  Liubov Samoylova,et al.  Cross-platform wave optics software for XFEL applications , 2011, Optical Engineering + Applications.

[7]  Manuel Sanchez del Rio,et al.  SHADOW3: a new version of the synchrotron X-ray optics modelling package , 2011, Journal of synchrotron radiation.

[8]  F. Zernike The concept of degree of coherence and its application to optical problems , 1938 .

[9]  Oleg Chubar,et al.  Recent updates in the “Synchrotron Radiation Workshop” code, on-going developments, simulation activities, and plans for the future , 2014, Optics & Photonics - Optical Engineering + Applications.

[10]  Oleg Chubar,et al.  Wavefront propagation simulations for beamlines and experiments with "Synchrotron Radiation Workshop" , 2013 .

[11]  Garth Wells,et al.  Characterization of the surface contamination of deep X-ray lithography mirrors exposed to synchrotron radiation. , 2018, Journal of synchrotron radiation.

[12]  M. Berry,et al.  Dislocations in wave trains , 1974, Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences.

[13]  Franco Gori,et al.  Partially polarized Gaussian Schell-model beams , 2001 .

[14]  R. Tai,et al.  Mutual optical intensity propagation through non-ideal mirrors. , 2017, Journal of synchrotron radiation.

[15]  M. Glass,et al.  Coherent modes of X-ray beams emitted by undulators in new storage rings , 2017, 1706.04393.

[16]  K. Nugent,et al.  Diffractive imaging using partially coherent x rays. , 2009, Physical review letters.

[17]  A Pacureanu,et al.  Holographic imaging with a hard x-ray nanoprobe: ptychographic versus conventional phase retrieval. , 2016, Optics letters.

[18]  Zach DeVito,et al.  Opt , 2017 .

[19]  Xianbo Shi,et al.  How to specify super-smooth mirrors: simulation studies on nano-focusing and wavefront preserving x-ray mirrors for next-generation light sources , 2016, International Symposium on Advanced Optical Manufacturing and Testing Technologies (AOMATT).

[20]  Bo Liu,et al.  Large-scale uniform Au nanodisk arrays fabricated via x-ray interference lithography for reproducible and sensitive SERS substrate , 2014, Nanotechnology.

[21]  F. Siewert,et al.  Propagation of coherent light pulses with PHASE , 2014, Optics & Photonics - Optical Engineering + Applications.

[22]  Sébastien Boutet,et al.  The Coherent X-ray Imaging instrument at the Linac Coherent Light Source , 2015, Journal of synchrotron radiation.

[23]  Yong Wang,et al.  Numerical analysis of partially coherent radiation at soft x-ray beamline. , 2015, Optics express.