Micropermeability of current self-etching and etch-and-rinse adhesives bonded to deep dentine: a comparison study using a double-staining/confocal microscopy technique.

Water sorption decreases the mechanical properties and the bond strengths of resin-bonded dentine. The aim of this study was to evaluate the micropermeability of several self-etching and etch-and-rinse adhesives. Optibond FL, Silorane, Scotchbond 1XT, G-Bond, and DC-Bond were bonded under simulated pulpal pressure. A 10 wt% solution of ammoniacal silver nitrate and a 1 wt% solution of rhodamine B were injected into the pulp chamber at 20 cm of water pressure. The dentine-adhesive interfaces were examined using a confocal scanning microscope. Micropermeability was detected in all the adhesives. DC-Bond, G-Bond, and Scotchbond 1XT showed voids along the resin-bonded interface. Silorane and Optibond FL showed an adhesive layer that was free from water trees and micropermeability. The double staining technique is a method that gives accurate results in the study of the resin-dentine micropermeability. Each class of adhesive has a different distribution of micropermeability. The higher the micropermeability, the higher the risk of defects at the resin-dentine interface, which may represent the pathway for hydrolytic and enzymatic degradation of resin-dentine bonds over time.

[1]  F. Tay,et al.  Microtensile dentin bond strength of self-etching resins: effect of a hydrophobic layer. , 2005, Operative dentistry.

[2]  N. King,et al.  Effect of resin hydrophilicity and temperature on water sorption of dental adhesive resins. , 2006, Biomaterials.

[3]  F. Tay,et al.  Dental adhesives of the future. , 2002, The journal of adhesive dentistry.

[4]  C. Dörfer,et al.  Effect of intrapulpal pressure simulation in vitro on shear bond strengths and hybrid layer formation. , 2001, American journal of dentistry.

[5]  J. Eick,et al.  Stability of silorane dental monomers in aqueous systems. , 2006, Journal of dentistry.

[6]  F. Tay,et al.  Use of Hoy's solubility parameters to predict water sorption/solubility of experimental primers and adhesives. , 2007, European journal of oral sciences.

[7]  M. Bravo,et al.  Effect of pulp pressure on the micropermeability and sealing ability of etch & rinse and self-etching adhesives. , 2007, Operative dentistry.

[8]  Yong Wang,et al.  Effect of acid etching time and technique on interfacial characteristics of the adhesive-dentin bond using differential staining. , 2004, European journal of oral sciences.

[9]  A. Akamine,et al.  Water absorption of poly(methyl methacrylate) containing 4-methacryloxyethyl trimellitic anhydride. , 2003, Biomaterials.

[11]  W. Weinmann,et al.  Siloranes in dental composites. , 2005, Dental materials : official publication of the Academy of Dental Materials.

[12]  M. Tyas,et al.  The effect of concentration and pH of silver nitrate solution on nanoleakage. , 2003, The journal of adhesive dentistry.

[13]  Adam M. Donnelly,et al.  Application of hydrophobic resin adhesives to acid-etched dentin with an alternative wet bonding technique. , 2008, Journal of biomedical materials research. Part A.

[14]  Franklin R. Tay,et al.  Have Dentin Adhesives Become Too Hydrophilic? (Les adhésifs dentinaires sont-ils devenus trop hydrophiles?) , 2003 .

[15]  C. Soles,et al.  A discussion of the molecular mechanisms of moisture transport in epoxy resins , 2000 .

[16]  C. Dörfer,et al.  The nanoleakage phenomenon: influence of different dentin bonding agents, thermocycling and etching time. , 2000, European journal of oral sciences.

[17]  T. Watson,et al.  The influence of dentine bonding systems and their handling characteristics on the morphology and micropermeability of the dentine adhesive interface. , 1999, Journal of dentistry.

[18]  M. Ferrari,et al.  Tubular Occlusion Optimizes Bonding of Hydrophobic Resins to Dentin , 2007, Journal of dental research.

[19]  J De Munck,et al.  Monomer-Solvent Phase Separation in One-step Self-etch Adhesives , 2005, Journal of dental research.

[20]  Shuichi Ito,et al.  Conversion of one-step to two-step self-etch adhesives for improved efficacy and extended application. , 2005, American journal of dentistry.

[21]  M Sherriff,et al.  Variable polymerisation shrinkage and the interfacial micropermeability of a dentin bonding system. , 1999, The journal of adhesive dentistry.

[22]  W. V. van Gunsteren,et al.  Cooperative effects in the transport of small molecules through an amorphous polymer matrix. , 1993, Journal of molecular graphics.

[23]  P. Lambrechts,et al.  Buonocore memorial lecture. Adhesion to enamel and dentin: current status and future challenges. , 2003, Operative dentistry.

[24]  J. Ferracane Hygroscopic and hydrolytic effects in dental polymer networks. , 2006, Dental materials : official publication of the Academy of Dental Materials.

[25]  M. Goot,et al.  Research reports , 1973 .

[26]  D. Pashley,et al.  Comparative SEM and TEM observations of nanoleakage within the hybrid layer. , 1995, Operative dentistry.

[27]  F. Tay,et al.  Effect of simulated pulpal pressure on dentin permeability and adhesion of self-etch adhesives. , 2007, Dental materials : official publication of the Academy of Dental Materials.

[28]  R. Hickel,et al.  Low-shrinkage composite for dental application. , 2007, Dental materials journal.

[29]  J. Román,et al.  A novel amphiphilic acrylic copolymer based on Triton X-100 for a poly(alkenoate) glass-ionomer cement. , 2006, Dental materials : official publication of the Academy of Dental Materials.

[30]  M. Tyas,et al.  Nanoleakage patterns of four dentin bonding systems. , 2000, Dental materials : official publication of the Academy of Dental Materials.

[31]  C. Davidson,et al.  Dentine permeability and bond quality as affected by new bonding systems. , 1995, Journal of dentistry.

[32]  G. Marshall,et al.  The influence of the dentin smear layer on adhesion: a self-etching primer vs. a total-etch system. , 2003, Dental materials : official publication of the Academy of Dental Materials.

[33]  M. Giannini,et al.  Effects of a peripheral enamel bond on the long-term effectiveness of dentin bonding agents exposed to water in vitro. , 2008, Journal of biomedical materials research. Part B, Applied biomaterials.

[34]  V. Sattabanasuk,et al.  Resin-dentin bond strength as related to different surface preparation methods. , 2007, Journal of dentistry.

[35]  F. Tay,et al.  Dentine sealing provided by smear layer/smear plugs vs. adhesive resins/resin tags. , 2007, European journal of oral sciences.

[36]  P. Lambrechts,et al.  Origin of Interfacial Droplets with One-step Adhesives , 2007, Journal of dental research.

[37]  D H Pashley,et al.  Two Modes of Nanoleakage Expression in Single-step Adhesives , 2002, Journal of dental research.

[38]  F. Tay,et al.  Water treeing--a potential mechanism for degradation of dentin adhesives. , 2003, American journal of dentistry.

[39]  F. Tay,et al.  Water treeing in simplified dentin adhesives--déjà vu? , 2005, Operative dentistry.

[40]  Shuichi Ito,et al.  Effects of resin hydrophilicity on water sorption and changes in modulus of elasticity. , 2005, Biomaterials.

[41]  D. Pashley Clinical correlations of dentin structure and function. , 1991, The Journal of prosthetic dentistry.

[42]  Yong Wang,et al.  Quantifying adhesive penetration in adhesive/dentin interface using confocal Raman microspectroscopy. , 2002, Journal of biomedical materials research.

[43]  T. Watson,et al.  Interfacial Characteristics of Resin-modified Glass-ionomer Materials: A Study on Fluid Permeability Using Confocal Fluorescence Microscopy , 1998, Journal of dental research.