A novel computer-assisted drill guide template for placement of C2 laminar screws

The present method of C2 laminar screw placement relies on anatomical landmarks for screw placement. Placement of C2 laminar screws using drill template has not been described in the literature. The authors reported on their experience with placement of C2 laminar screws using a novel computer-assisted drill guide template in nine patients undergoing posterior occipito-cervical fusion. CT scan of C2 vertebrae was performed. 3D model of C2 vertebrae was reconstructed by software MIMICS 10.01. The 3D vertebral model was then exported in STL format, and opened in a workstation running software UG imageware12.0 for determining the optimal laminar screw size and orientation. A virtual navigational template was established according to the laminar anatomic trait. The physical vertebrae and navigational template were manufactured using rapid prototyping. The navigational template was sterilized and used intraoperative to assist the placement of laminar screw. Overall, 19 C2 laminar screws were placed and the accuracy of screw placement was confirmed with postoperative X-ray and CT scanning. There were not complications of related screws insertion. Average follow-up was 9 months (range 4–13 months), 77.8% of the patients exhibited improvement in their myelopathic symptoms; in 22.2% the symptoms were unchanged. Postoperative computed tomographic (CT) scanning was available for allowing the evaluation of placement of thirteen C2 laminar screws, all of which were in good position with no spinal canal violation. This study shows a patient-specific template technique that is easy to use, can simplify the surgical act and generates highly accurate C2 laminar screw placement. Advantages of this technology over traditional techniques include planning of the screw trajectory is done completely in the presurgical period as well as the ability to size the screw to the patient’s anatomy.

[1]  K. Takaoka,et al.  Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. , 2000, Journal of spinal disorders.

[2]  K. Otani,et al.  Anatomic Study of the Axis for Surgical Planning of Transarticular Screw Fixation , 2003, Clinical orthopaedics and related research.

[3]  J Vander Sloten,et al.  Three-Dimensional Computed Tomography-Based, Personalized Drill Guide for Posterior Cervical Stabilization at C1–C2 , 2001, Spine.

[4]  Michael Y. Wang C2 Crossing Laminar Screws: Cadaveric Morphometric Analysis , 2006, Neurosurgery.

[5]  A. Brooks,et al.  Atlanto-axial arthrodesis by the wedge compression method. , 1978, The Journal of bone and joint surgery. American volume.

[6]  M. Aebi,et al.  Atlanto-axial fusion with transarticular screw fixation. , 1991, The Journal of bone and joint surgery. British volume.

[7]  Timothy C Ryken,et al.  Rapid prototype patient-specific drill template for cervical pedicle screw placement , 2007, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[8]  Marcel Rooze,et al.  Evaluation of a transpedicular drill guide for pedicle screw placement in the thoracic spine , 2003, European Spine Journal.

[9]  N. Wright,et al.  Pediatric atlantoaxial fixation with bilateral, crossing C-2 translaminar screws. Technical note. , 2006, Journal of neurosurgery.

[10]  N. Wright Posterior C2 Fixation Using Bilateral, Crossing C2 Laminar Screws: Case Series and Technical Note , 2004, Journal of spinal disorders & techniques.

[11]  E. Benzel Anatomic consideration of C2 pedicle screw placement. , 1996, Spine.

[12]  Accuracy of Intraoperative Plain Radiographs to Detect Violations of Intralaminar Screws Placed Into the C2 Vertebrae: A Reliability Study , 2007, Spine.

[13]  C. Petersilge,et al.  Morphologic Considerations of C2 Isthmus Dimensions for the Placement of Transarticular Screws , 2000, Spine.

[14]  K. Radermacher,et al.  Computer assisted orthopaedic surgery with image based individual templates. , 1998, Clinical orthopaedics and related research.

[15]  C. Dickman,et al.  Posterior atlantoaxial facet screw fixation. , 1993, Journal of neurosurgery.

[16]  B B Seedhom,et al.  Personalised image-based templates for intra-operative guidance , 2005, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[17]  C. Puttlitz,et al.  Constructs Incorporating Intralaminar C2 Screws Provide Rigid Stability for Atlantoaxial Fixation , 2005, Spine.

[18]  K. Bulsara,et al.  Utility of Computerized Isocentric Fluoroscopy for Minimally Invasive Spinal Surgical Techniques , 2005, Journal of spinal disorders & techniques.

[19]  N. Wright Translaminar rigid screw fixation of the axis. Technical note. , 2005, Journal of neurosurgery. Spine.

[20]  M. Hadley,et al.  The interspinous method of posterior atlantoaxial arthrodesis. , 1991, Journal of neurosurgery.

[21]  D. Resnick,et al.  Biomechanical Comparison of Four C1 to C2 Rigid Fixative Techniques: Anterior Transarticular, Posterior Transarticular, C1 to C2 Pedicle, and C1 to C2 Intralaminar Screws , 2006, Neurosurgery.

[22]  G. Deuretzbacher,et al.  Computer Navigation of Parapedicular Screw Fixation in the Thoracic Spine: A Cadaver Study , 2001, Spine.

[23]  Nicholas Theodore,et al.  Intraoperative Iso-C C-arm Navigation in Cervical Spinal Surgery: Review of the First 52 Cases , 2004, Spine.

[24]  C L Branch,et al.  Arteriovenous fistula as a complication of C1-2 transarticular screw fixation. Case report and review of the literature. , 1996, Journal of neurosurgery.

[25]  N. Wright,et al.  Vertebral artery injury in C1-2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. American Association of Neurological Surgeons/Congress of Neurological Surgeons. , 1998, Journal of neurosurgery.

[26]  F. Magerl,et al.  Primary posterior fusion C1/2 in odontoid fractures: indications, technique, and results of transarticular screw fixation. , 1992, Journal of spinal disorders.

[27]  H A Crockard,et al.  Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. , 1997, Journal of neurosurgery.

[28]  John A. Wilson,et al.  Atlanto-axial stabilization with posterior transarticular screw fixation: technical description and report of 22 cases. , 1993, Neurosurgery.