Hysteretic control of grid-side current for a single-phase LCL grid-connected voltage source converter

This paper proposes a new approach to control the grid-side current of LCL-grid connected voltage source converters using hysteretic relay feedback controllers. The closed loop system is stabilized by designing a local feedback around the relay element. The compensator allows the use of relay feedback controllers by making the controlled plant almost strictly positive real. The article proposes the use of the locus of the perturbed relay system as analysis and design tool and studies orbital stability for several plant and controller conditions. The approach is validated by means of simulation testing.

[1]  I︠a︡. Z. T︠S︡ypkin Relay Control Systems , 1985 .

[2]  Brian D. O. Anderson,et al.  Network Analysis and Synthesis: A Modern Systems Theory Approach , 2006 .

[3]  J.W. Kolar,et al.  A modified direct power control strategy allowing the connection of three-phase inverter to the grid through LCL filters , 2005, Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005..

[4]  Karl Johan Åström,et al.  Oscillations in Systems with Relay Feedback , 1993 .

[5]  Paolo Tenti,et al.  A novel hysteresis control method for current-controlled voltage-source PWM inverters with constant modulation frequency , 1990 .

[6]  I. Rusnak,et al.  The duality of parallel feedforward and negative feedback , 2012, 2012 IEEE 27th Convention of Electrical and Electronics Engineers in Israel.

[7]  V. Blasko,et al.  A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter , 1997 .

[8]  Toshihiko Noguchi,et al.  A New Quick-Response and High-Efficiency Control Strategy of an Induction Motor , 1986, IEEE Transactions on Industry Applications.

[9]  I. Mizumoto,et al.  Realization of simple adaptive control by using parallel feedforward compensator , 1994 .

[10]  B. Bose An adaptive hysteresis-band current control technique of a voltage-fed PWM inverter for machine drive system , 1990 .

[11]  Humberto Pinheiro,et al.  Adaptive current control of grid-connected VSC with LCL-filters using parallel feedforward compensation , 2010, IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society.

[12]  D. G. Holmes,et al.  An Improved Three-Phase Variable-Band Hysteresis Current Regulator , 2013, IEEE Transactions on Power Electronics.

[13]  R. Gessing,et al.  Parallel Compensator for Continuous and Relay Control Systems with Difficult Plants , 2007, 2007 American Control Conference.

[14]  S. Cobreces,et al.  Influence analysis of the effects of an inductive-resistive weak grid over L and LCL filter current hysteresis controllers , 2007, 2007 European Conference on Power Electronics and Applications.

[15]  Bong-Hwan Kwon,et al.  A novel SVM-based hysteresis current controller , 1998 .

[16]  A. F. Wick,et al.  Design and Experimental Results of a Brushless AC Servo Drive , 1984, IEEE Transactions on Industry Applications.

[17]  Rajesh Gupta,et al.  Reduced state feedback sliding-mode current control for voltage source inverter-based higher-order circuit , 2015 .

[18]  M. Depenbrock,et al.  Direct self-control (DSC) of inverter-fed induction machine , 1988 .

[19]  Igorʹ. Boĭko Discontinuous Control Systems , 2008 .

[20]  Howard Kaufman,et al.  Direct adaptive control algorithms: theory and applications , 1993, Choice Reviews Online.

[21]  Donald Grahame Holmes,et al.  A simple, novel method for variable-hysteresis-band current control of a three phase inverter with constant switching frequency , 1993, Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting.

[22]  Ilan Rusnak,et al.  SPR and ASPR Untangled , 2009 .

[23]  Tao Liu,et al.  A Sliding-Mode Controller With Multiresonant Sliding Surface for Single-Phase Grid-Connected VSI With an LCL Filter , 2013, IEEE Transactions on Power Electronics.