Tricuspid annular geometry: a three-dimensional transesophageal echocardiographic study.

OBJECTIVE To demonstrate the clinical feasibility of accurately measuring tricuspid annular area by 3-dimensional (3D) transesophageal echocardiography (TEE) and to assess the geometric differences based on the presence of tricuspid regurgitation (TR). Also, the shape of the tricuspid annulus was compared with previous descriptions in the literature. DESIGN Prospective. SETTING Tertiary care university hospital. INTERVENTIONS Three-dimensional TEE. PARTICIPANTS Patients undergoing cardiac surgery. MEASUREMENTS AND MAIN RESULTS Volumetric data sets from 20 patients were acquired by 3D TEE and prospectively analyzed. Comparisons in annular geometry were made between groups based on the presence of TR. The QLab (Philips Medical Systems, Andover, MA) software package was used to calculate tricuspid annular area by both linear elliptical dimensions and planimetry. Further analyses were performed in the 4D Cardio-View (TomTec Corporation GmBH, Munich, Germany) and MATLAB (Natick, MA) software environments to accurately assess annular shape. It was found that patients with greater TR had an eccentrically dilated annulus with a larger annular area. Also, the area as measured by the linear ellipse method was overestimated as compared to the planimetry method. Furthermore, the irregular saddle-shaped geometry of the tricuspid annulus was confirmed through the mathematic model developed by the authors. CONCLUSIONS Three-dimensional TEE can be used to measure the tricuspid annular area in a clinically feasible fashion, with an eccentric dilation seen in patients with TR. The tricuspid annulus shape is complex, with annular high and low points, and annular area calculation based on linear measurements significantly overestimates 3D planimetered area.

[1]  G. Dreyfus,et al.  Secondary tricuspid regurgitation or dilatation: which should be the criteria for surgical repair? , 2005, The Annals of thoracic surgery.

[2]  S. Bolling,et al.  Valve repair for functional tricuspid valve regurgitation: anatomical and surgical considerations. , 2010, Seminars in thoracic and cardiovascular surgery.

[3]  T. Naqvi,et al.  Advances in 3D echocardiography for mitral valve , 2011, Expert review of cardiovascular therapy.

[4]  P. D. del Nido,et al.  In Vitro Characterization of the Mechanisms Responsible for Functional Tricuspid Regurgitation , 2011, Circulation.

[5]  Helmut Baumgartner,et al.  Guidelines on the management of valvular heart disease The Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology , 2007 .

[6]  J. Hung The pathogenesis of functional tricuspid regurgitation. , 2010, Seminars in thoracic and cardiovascular surgery.

[7]  C. Mazer,et al.  Complete mapping of the tricuspid valve apparatus using three-dimensional sonomicrometry. , 2011, The Journal of thoracic and cardiovascular surgery.

[8]  D. Adams,et al.  Tricuspid valve repair for treatment and prevention of secondary tricuspid regurgitation in patients undergoing mitral valve surgery , 2008, Current cardiology reports.

[9]  Susan Armstrong,et al.  Tricuspid Valve Repair With an Annuloplasty Ring Results in Improved Long-Term Outcomes , 2006, Circulation.

[10]  C. Duran,et al.  Progression of Tricuspid Regurgitation After Repaired Functional Ischemic Mitral Regurgitation , 2005, Circulation.

[11]  Woo-Hyung Lee,et al.  3D geometry of a normal tricuspid annulus during systole: a comparison study with the mitral annulus using real-time 3D echocardiography. , 2007, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[12]  Haider J. Warraich,et al.  Mitral annular nonplanarity: correlation between annular height/commissural width ratio and the nonplanarity angle. , 2012, Journal of cardiothoracic and vascular anesthesia.

[13]  J. Chikwe,et al.  Surgical strategies for functional tricuspid regurgitation. , 2010, Seminars in thoracic and cardiovascular surgery.

[14]  Robert A Levine,et al.  Geometric Determinants of Functional Tricuspid Regurgitation: Insights From 3-Dimensional Echocardiography , 2006, Circulation.

[15]  Otto Kamp,et al.  Three-dimensional echocardiography in mitral valve disease. , 2005, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[16]  J. Smallhorn,et al.  Three-dimensional tricuspid annular function provides insight into the mechanisms of tricuspid valve regurgitation in classic hypoplastic left heart syndrome. , 2006, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[17]  Karen Parker,et al.  Dynamics of the tricuspid valve annulus in normal and dilated right hearts: a three-dimensional transoesophageal echocardiography study. , 2012, European heart journal cardiovascular Imaging.

[18]  O. Alfieri,et al.  Evolution of tricuspid regurgitation after mitral valve repair for functional mitral regurgitation in dilated cardiomyopathy. , 2008, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[19]  S. Gallina,et al.  Mitral valve surgery for functional mitral regurgitation: should moderate-or-more tricuspid regurgitation be treated? a propensity score analysis. , 2009, The Annals of thoracic surgery.

[20]  Ajit P. Yoganathan,et al.  The Effects of a Three-Dimensional, Saddle-Shaped Annulus on Anterior and Posterior Leaflet Stretch and Regurgitation of the Tricuspid Valve , 2011, Annals of Biomedical Engineering.

[21]  E. Schwammenthal,et al.  Determinants of functional tricuspid regurgitation in incomplete tricuspid valve closure: Doppler color flow study of 109 patients. , 1994, Journal of the American College of Cardiology.

[22]  F. T. ten Cate,et al.  Assessment of tricuspid valve annulus size, shape and function using real-time three-dimensional echocardiography. , 2006, Interactive cardiovascular and thoracic surgery.

[23]  Giuseppe Saracino,et al.  Three-Dimensional Geometry of the Tricuspid Annulus in Healthy Subjects and in Patients With Functional Tricuspid Regurgitation: A Real-Time, 3-Dimensional Echocardiographic Study , 2006, Circulation.