A surface plasmon resonance immunosensor for detecting a dioxin precursor using a gold binding polypeptide.

A surface plasmon resonance (SPR) based biosensor was developed for monitoring 2,4-dichlorophenol, a known dioxin precursor, using an indirect competitive immunoassay. The SPR sensor was fabricated by immobilizing a gold-thin layer on the surface of an SPR sensor chip with an anti-(2,4-dichlorophenol) antibody using a gold binding polypeptide (GBP) and protein G. The SPR response based on the antigen-antibody reaction in a flow system was measured by injecting a 2,4-dichlorophenol sample solution into the flow system in which the SPR sensor was located. In a direct immunoassay system using the modified sensor chip, no significant SPR angle shift less than 0.001 degrees was observed when a 25 ppm of 2,4-dichlorophenol solution was injected. In order to improve the sensitivity of the SPR sensor, an indirect competitive immunoassay method was used in conjunction with the SPR sensor system using 2,4-dichlorophenol conjugated with bovine serum albumin (BSA). In the competitive assay, a 350 ppm 2,4-dichlorophenol-BSA conjugate solution containing 2,4-dichlorophenol at various concentrations (10-250 ppb) were injected into the SPR sensor system. The sensitivity of this indirect immunoassay was found to be extremely sensitive, compared to the direct one, and a detection limit of 20 ppb was estimated. Verification that the use of GBP for immobilizing the antibody on the sensor chip enhanced the sensitivity to 2,4-dichlorophenol was obtained by comparing the procedure with another modification, in which BSA was used instead of GBP for immobilizing the antibody on the sensor chip. The affinity constant of 2,4-dichlorophenol and its conjugate to the antibody were estimated form the SPR response.

[1]  P. Vercellini,et al.  Seveso Women's Health Study: a study of the effects of 2,3,7,8-tetrachlorodibenzo-p-dioxin on reproductive health. , 2000, Chemosphere.

[2]  N. Keiding,et al.  Declining semen quality and increasing incidence of testicular cancer: is there a common cause? , 1995, Environmental health perspectives.

[3]  K. Olie,et al.  Mechanisms of Formation and Destruction of Polychlorinated Dibenzo=p=dioxins and Dibenzofurans in Heterogeneous Systems , 1995 .

[4]  B D Hammock,et al.  Development of a highly sensitive enzyme-linked immunosorbent assay based on polyclonal antibodies for the detection of polychlorinated dibenzo-p-dioxins. , 1998, Analytical chemistry.

[5]  Stanley Brown,et al.  Metal-recognition by repeating polypeptides , 1997, Nature Biotechnology.

[6]  F. Scheller,et al.  Sensitive detection of triazine and phenylurea pesticides in pure organic solvent by enzyme linked immunosorbent assay (ELISA): stabilities, solubilities and sensitivities , 2000 .

[7]  D. Schrenk Impact of dioxin-type induction of drug-metabolizing enzymes on the metabolism of endo- and xenobiotics. , 1998, Biochemical pharmacology.

[8]  T. Küchler,et al.  Application of GC-MS/MS for the analysis of PCDD/Fs in sewage effluents. , 2000, Chemosphere.

[9]  G. O. Thomas,et al.  Methods for the analysis of PCBs in human food, faeces and serum. , 1999, Chemosphere.

[10]  J. L. Zajicek,et al.  Comparison of an enzyme-linked immunosorbent assay (ELISA) to gas chromatography (GC)--measurement of polychlorinated biphenyls (PCBs) in selected US fish extracts. , 2000, Chemosphere.

[11]  Performance characteristics for flow injection immunoassay using monoclonal antibodies against s-triazine and 2,4-D herbicides. , 2000 .

[12]  Guomin Shan,et al.  Highly sensitive dioxin immunoassay and its application to soil and biota samples , 2001 .

[13]  T. Imasaka,et al.  Supersonic jet/multiphoton ionization/mass spectrometry of dioxins formed by the thermal reaction of phenols in the absence and presence of an FeCl3 catalyst. , 2000, Analytical chemistry.

[14]  M. J. Eddowes,et al.  Surface plasmon resonance applied to immunosensing , 1988 .

[15]  Steven F. Arnold,et al.  Synergistic Activation of Estrogen Receptor with Combinations of Environmental Chemicals , 1996, Science.

[16]  J. Clendenning,et al.  Construction of biosensors using a gold-binding polypeptide and a miniature integrated surface plasmon resonance sensor. , 1998, Biosensors & bioelectronics.

[17]  Bertold Hock,et al.  Development of an enzyme linked receptor assay (ELRA) for estrogens and xenoestrogens , 1999 .

[18]  U. Bolz,et al.  Development and validation of a GC/MS method for determination of phenolic xenoestrogens in aquatic samples. , 2000, Chemosphere.

[19]  W. Benson,et al.  Environmental estrogenic effects of alkylphenol ethoxylates. , 1996, Critical reviews in toxicology.

[20]  G. Eiceman,et al.  Mechanism of chlorination of aromatic compounds adsorbed on the surface of fly ash from municipal incinerators , 1990 .

[21]  Norio Miura,et al.  Highly selective and sensitive SPR immunosensor for detection of methamphetamine , 1999 .

[22]  Dianne Dumanoski,et al.  Our Stolen Future , 1996 .

[23]  I. Karube,et al.  Simple and rapid detection method using surface plasmon resonance for dioxins, polychlorinated biphenylx and atrazine , 2001 .