Spatial and Temporal Variations in Indoor Environmental Conditions, Human Occupancy, and Operational Characteristics in a New Hospital Building

The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogate measures for human occupancy and activity in the patient rooms using both indoor air CO2 concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ∼8×106 data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections.

[1]  R. Hobday,et al.  Roles of sunlight and natural ventilation for controlling infection: historical and current perspectives , 2013, Journal of Hospital Infection.

[2]  William W. Nazaroff,et al.  Human Occupancy as a Source of Indoor Airborne Bacteria , 2012, PloS one.

[3]  Olivier Thomas,et al.  VOC Contamination in Hospital, from Stationary Sampling of a Large Panel of Compounds, in View of Healthcare Workers and Patients Exposure Assessment , 2013, PloS one.

[4]  Refrigerating ASHRAE handbook of fundamentals , 1967 .

[5]  J. Skoog Relative Air Humidity in Hospital Wards – User Perception and Technical Consequences , 2006 .

[6]  C. Makison,et al.  The Effect of Humidity on the Survival of MRSA on Hard Surfaces , 2006 .

[7]  Lennart Jagemar,et al.  Thermal environment in Swedish hospitals: Summer and winter measurements , 2005 .

[8]  Ruey Lung Hwang,et al.  Patient thermal comfort requirement for hospital environments in Taiwan , 2007 .

[9]  Tu Guangbei,et al.  Study on biological contaminant control strategies under different ventilation models in hospital operating room , 2008 .

[10]  H. Humphreys,et al.  Positive-pressure isolation and the prevention of invasive aspergillosis. What is the evidence? , 2004, The Journal of hospital infection.

[11]  Rob Knight,et al.  Longitudinal analysis of microbial interaction between humans and the indoor environment , 2014, Science.

[12]  B. Turpin,et al.  Shifts in the Gas-Particle Partitioning of Ambient Organics with Transport into the Indoor Environment , 2014 .

[13]  Jeffrey Shaman,et al.  Absolute humidity modulates influenza survival, transmission, and seasonality , 2009, Proceedings of the National Academy of Sciences.

[14]  A. Kramer,et al.  How long do nosocomial pathogens persist on inanimate surfaces? A systematic review , 2006, BMC infectious diseases.

[15]  Edward Arens,et al.  Indoor humidity and human health. Part 1: Literature review of health effects of humidity-influenced indoor pollutants , 1996 .

[16]  O. Faure,et al.  Eight-year surveillance of environmental fungal contamination in hospital operating rooms and haematological units. , 2002, The Journal of hospital infection.

[17]  J R Songer,et al.  Influence of relative humidity on the survival of some airborne viruses. , 1967, Applied microbiology.

[18]  I. Eames,et al.  Airborne transmission of disease in hospitals , 2009, Journal of The Royal Society Interface.

[19]  Francisco Javier Rey-Martínez,et al.  Study on environmental quality of a surgical block , 1999 .

[20]  S. Green,et al.  Preventing Airborne Disease Transmission: Review of Methods for Ventilation Design in Health Care Facilities , 2011, Advances in preventive medicine.

[21]  L. Bekker,et al.  Shared Air: A Renewed Focus on Ventilation for the Prevention of Tuberculosis Transmission , 2014, PloS one.

[22]  A. Webster,et al.  Some factors affecting airborne survival of Pseudomonas fluorescens indoors. , 1993, The Journal of applied bacteriology.

[23]  Constantinos A. Balaras,et al.  HVAC and indoor thermal conditions in hospital operating rooms , 2007 .

[24]  Chin-Sheng Tang,et al.  Long-term surveillance of air quality in medical center operating rooms. , 2011, American journal of infection control.

[25]  Julian W. Tang,et al.  The effect of environmental parameters on the survival of airborne infectious agents , 2009, Journal of The Royal Society Interface.

[26]  K. Welch,et al.  Evaluation of Hospital Room Assignment and Acquisition of Clostridium difficile Infection , 2011, Infection Control & Hospital Epidemiology.

[27]  Michelle Shardell,et al.  Seasonal and Temperature-Associated Increases in Gram-Negative Bacterial Bloodstream Infections among Hospitalized Patients , 2011, PloS one.

[28]  Sharron McEldowney,et al.  The effect of temperature and relative humidity on the survival of bacteria attached to dry solid surfaces , 1988 .

[29]  Michael L. Kashon,et al.  High Humidity Leads to Loss of Infectious Influenza Virus from Simulated Coughs , 2013, PloS one.

[30]  L. T. Wong,et al.  An evaluation model for indoor environmental quality (IEQ) acceptance in residential buildings , 2009 .

[31]  Jeff Kline,et al.  Architectural Design Drives the Biogeography of Indoor Bacterial Communities , 2014, PloS one.

[32]  Brent Stephens,et al.  Tools to improve built environment data collection for indoor microbial ecology investigations , 2014 .

[33]  Constantinos A. Balaras,et al.  Indoor environmental quality in Hellenic hospital operating rooms , 2009 .

[34]  Andreas Wilke,et al.  MIxS-BE: a MIxS extension defining a minimum information standard for sequence data from the built environment , 2013, The ISME Journal.

[35]  Jeff Kline,et al.  Architectural design influences the diversity and structure of the built environment microbiome , 2012, The ISME Journal.

[36]  C. Keevil,et al.  Potential use of copper surfaces to reduce survival of epidemic meticillin-resistant Staphylococcus aureus in the healthcare environment. , 2006, The Journal of hospital infection.

[37]  Francis Rubinstein,et al.  Modeling occupancy in single person offices , 2005 .

[38]  Constantinos A. Balaras,et al.  Air quality in hospital operating rooms , 2008 .

[39]  J. Heritage,et al.  Influence of relative humidity and suspending menstrua on survival of Acinetobacter spp. on dry surfaces , 1996, Journal of clinical microbiology.

[40]  Jamal Khodakarami,et al.  Thermal comfort in hospitals – A literature review , 2012 .

[41]  Francis Rubinstein,et al.  Analyzing occupancy profiles from a lighting controls field study , 2003 .

[42]  Courtney Coughenour,et al.  An evaluation of methicillin-resistant Staphylococcus aureus survival on five environmental surfaces. , 2011, Microbial drug resistance.

[43]  S. Sattar,et al.  Effect of relative humidity on the airborne survival of rotavirus SA11 , 1984, Applied and environmental microbiology.

[44]  S. Sattar,et al.  Effect of relative humidity and air temperature on survival of hepatitis A virus on environmental surfaces , 1991, Applied and environmental microbiology.

[45]  W W Nazaroff,et al.  Size-resolved emission rates of airborne bacteria and fungi in an occupied classroom , 2012, Indoor air.

[46]  Richard Platt,et al.  Risk of acquiring antibiotic-resistant bacteria from prior room occupants. , 2006, Archives of internal medicine.

[47]  Chin-Sheng Tang,et al.  Air Quality Monitoring of the Post-Operative Recovery Room and Locations Surrounding Operating Theaters in a Medical Center in Taiwan , 2013, PloS one.

[48]  K W Tham,et al.  Size relationship between airborne viable bacteria and particles in a controlled indoor environment study. , 2005, Indoor air.

[49]  S. Sattar,et al.  Effect of relative humidity on the airborne survival of rhinovirus-14. , 1985, Canadian journal of microbiology.

[50]  S. Nasraway,et al.  Prior environmental contamination increases the risk of acquisition of vancomycin-resistant enterococci. , 2008, Clinical infectious diseases : an official publication of the Infectious Diseases Society of America.

[51]  S. Sattar,et al.  Effect of relative humidity, atmospheric temperature, and suspending medium on the airborne survival of human rotavirus. , 1985, Canadian journal of microbiology.

[52]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[53]  Y. Drabu,et al.  Importance of air quality and related factors in the prevention of infection in orthopaedic implant surgery. , 1998, The Journal of hospital infection.

[54]  R. Girones,et al.  Effect of temperature and sunlight on the stability of human adenoviruses and MS2 as fecal contaminants on fresh produce surfaces. , 2013, International journal of food microbiology.

[55]  M J Mendell,et al.  Indoor thermal factors and symptoms in office workers: findings from the US EPA BASE study. , 2008, Indoor air.