Permittivity measurements up to 30 GHz using micromachined probe

We implemented a micromachined probe for the measurement of biological properties using MEMS technology, and experimentally showed the suitability of the micromachined probe in biological applications. The micromachined probe was fabricated on a silicon substrate, and to remove wave transmission through the silicon substrate, we etched the silicon substrate from beneath a lower ground and made the etched silicon surface conducting by using thermal evaporation of Cr/Au and a coating of conductive epoxy. The micromachined probe consists of a CPW and strip line between benzo cyclo butene (BCB) layers, which is known to be a material with high resistivity, low loss tangent, and low permittivity at high frequency. We measured the permittivity of a number of well-known liquids—0.5%, 0.9% and 1.3% saline, acetone, ethanol, and muscle and fat of pork—as biological samples using the micromachined probe after liquid calibration. The measured permittivity of 0.9% saline agreed well with the expected value of the Cole–Cole equation. In this paper, we first demonstrate that the micromachined probe can provide broadband measurement of measurable solid materials, such as biological samples, and also of well-known liquids at microwave frequencies. The size of the micromachined probe is 2000 µm (width) × 580 µm (thickness) × 30 000 µm (length), and the aperture size of the micromachined probe is only 650 µm × 70 µm. Therefore, we can extract the biological information from very small biological tissues and reduce radiation effects. Thus we show the feasibility of low-cost, small and portable permittivity measurement systems using a micromachined open-ended coaxial RF MEMS probe.

[1]  C. Cheon,et al.  110 GHz broadband measurement of permittivity on human epidermis using 1 mm coaxial probe , 2003, IEEE MTT-S International Microwave Symposium Digest, 2003.

[2]  M. Okoniewski,et al.  Sensing volume of open-ended coaxial probes for dielectric characterization of breast tissue at microwave frequencies , 2003, IEEE Antennas and Propagation Society International Symposium. Digest. Held in conjunction with: USNC/CNC/URSI North American Radio Sci. Meeting (Cat. No.03CH37450).

[3]  Maria A. Stuchly,et al.  Measurement of Radio Frequency Permittivity of Biological Tissues with an Open-Ended Coaxial Line: Part I , 1982 .

[4]  S. S. Stuchly,et al.  Permittivity measurements using open-ended sensors and reference liquid calibration-an uncertainty analysis , 1992 .

[5]  S. Sridhar,et al.  Radiation-corrected open-ended coax line technique for dielectric measurements of liquids up to 20 GHz , 1991 .

[6]  T. W. Athey,et al.  Measurement of Radio Frequency Permittivity of Biological Tissues with an Open-Ended Coaxial Line: Part II - Experimental Results , 1982 .

[7]  I. Huynen,et al.  Measurements of complex permittivity of biological and organic liquids up to 110 GHz , 1997, 1997 IEEE MTT-S International Microwave Symposium Digest.

[8]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[9]  C Gabriel,et al.  The dielectric properties of biological tissues: I. Literature survey. , 1996, Physics in medicine and biology.

[10]  Srinivas Sridhar,et al.  Technique for measuring the frequency‐dependent complex dielectric constants of liquids up to 20 GHz , 1989 .

[11]  Michio Miyakawa,et al.  A numerical study on the measurement region of an open-ended coaxial probe used for complex permittivity measurement , 2001 .