A Coordinated Recloser-Fusesaver Method for Reliability Enhancement of Distribution Networks

Medium voltage distribution networks lack the adequate capability of being remotely monitored, controlled and having smart response due to their traditional and low-level automated protection devices. This paper assesses the reliability and performance improvement in medium voltage distribution networks after increasing the system automation by applying the fusesaver device on lateral line coordinated with the recloser device on the main feeder line. All nowadays applied advanced devices and previous solution scenarios are discussed and summarized through a critical literature review. The detailed methodology for the fusesaver coordinated implementation is explained. The evaluation can be achieved by calculating in a historical way the most common distribution system reliability indices, then a comparison between the case study results before and after fusesaver installation is presented. As a result, an enormous reduction occurred in outage frequency and duration, and the number of affected customers. Moreover, online monitoring of the line helped in estimating fault location and giving precise control decisions.

[1]  M. R. Elkadeem,et al.  Reliability Improvement of Power Distribution Systems using Advanced Distribution Automation , 2017 .

[2]  Damir Novosel,et al.  Automated solutions for distribution feeders , 2000 .

[3]  Li Wang,et al.  The Fault Causes of Overhead Lines in Distribution Network , 2016 .

[4]  L.A. Elder,et al.  Economic optimisation of an Australian rural electricity network using automatic circuit reclosers with remote monitoring & control , 1999, 1999 IEEE Transmission and Distribution Conference (Cat. No. 99CH36333).

[5]  Zahir Hoosain Khan Improving the reliability performance of medium voltage networks , 2015 .

[6]  P. Chandhra Sekhar,et al.  Evaluation and improvement of reliability indices of electrical power distribution system , 2016, 2016 National Power Systems Conference (NPSC).

[7]  Hamid Sharif,et al.  A Survey on Smart Grid Communication Infrastructures: Motivations, Requirements and Challenges , 2013, IEEE Communications Surveys & Tutorials.

[8]  Michael G. Ennis,et al.  Application of cutout type reclosers on distribution lateral circuits — A field study , 2009, 2009 IEEE Power & Energy Society General Meeting.

[9]  N. Eva Wu,et al.  Recloser and sectionalizer placement for reliability improvement using discrete event simulation , 2014, 2014 IEEE PES General Meeting | Conference & Exposition.

[10]  Kevin Tomsovic,et al.  Event analysis of pulse-reclosers in distribution systems through sparse representation , 2017, 2017 19th International Conference on Intelligent System Application to Power Systems (ISAP).

[11]  Yi Xu,et al.  A survey on the communication architectures in smart grid , 2011, Comput. Networks.

[12]  Dragan S. Popovic,et al.  Optimal automation level of medium voltage distribution network , 2005 .