Process characterization of powder blending by near-infrared spectroscopy: blend end-points and beyond.

The purpose of this paper is to utilize near-infrared (NIR) spectroscopy to characterize powder blending in-line. A multivariate model-based approach was used to determine end-point and variability at the end-point of blending processes. Two monitoring positions for NIR spectrometers were evaluated; one was located on the top of the Bin-blender and the other was on the rotation axis. A ternary powder mixture including acetaminophen (APAP, fine and coarse powder), lactose (LAC) and microcrystalline cellulose (MCC, Avicel 101 and 200) was used as a test system. A Plackett-Burman design of experiments (DOE) for different blending parameters and compositions was utilized to compare the robustness of end-point determination between the multivariate model-based algorithm and reference algorithms. The end-point determination algorithm, including root mean square from nominal value (RMSNV) and two-tailed Student's t-test, was developed based on PLS predicted concentrations of all three constituents. Mean and standard deviation of RMSNV after end-point were used to characterize blending variability at the end-point. The blending end-point and variability of two sensors were also compared. The multivariate model-based algorithm proved to be more robust on end-point determination compared to the reference algorithms. Blending behavior at the two sensor locations demonstrated a significant difference in terms of end-point and blending variability, indicating the advantage to employ process monitoring via NIR spectroscopy on more than one location on the Bin-blender.

[1]  Rodolfo J. Romañach,et al.  Blend uniformity analysis using stream sampling and near infrared spectroscopy , 2002, AAPS PharmSciTech.

[2]  Fernando Muzzio,et al.  A Homogeneity Study Using NIR Spectroscopy: Tracking Magnesium Stearate in Bohle Bin-Blender , 2003, Drug development and industrial pharmacy.

[3]  J. Drennen,et al.  Near-infrared spectroscopy and imaging for the monitoring of powder blend homogeneity. , 2001, Journal of pharmaceutical sciences.

[4]  D. Massart,et al.  Monitoring powder blending by NIR spectroscopy , 1995 .

[5]  E Bertran,et al.  Monitoring powder blending in pharmaceutical processes by use of near infrared spectroscopy. , 2002, Talanta.

[6]  J. Drennen,et al.  Near-infrared spectroscopic characterization of pharmaceutical powder blends. , 1996, Journal of pharmaceutical and biomedical analysis.

[7]  James K Drennen,et al.  A Process Analytical Technology approach to near-infrared process control of pharmaceutical powder blending: Part II: Qualitative near-infrared models for prediction of blend homogeneity. , 2006, Journal of pharmaceutical sciences.

[8]  Gabriele Reich,et al.  Near-infrared spectroscopy and imaging: basic principles and pharmaceutical applications. , 2005, Advanced drug delivery reviews.

[9]  S. Sekulic,et al.  Automated system for the on-line monitoring of powder blending processes using near-infrared spectroscopy. Part II. Qualitative approaches to blend evaluation. , 1998, Journal of pharmaceutical and biomedical analysis.

[10]  Paul J. Gemperline,et al.  Effective mass sampled by NIR fiber-optic reflectance probes in blending processes , 1997 .

[11]  F. Muzzio,et al.  The structure of mixtures of particles generated by time-dependent flows , 1995 .

[12]  Robert A Reed,et al.  Comparison of Near-Infrared and Laser-Induced Breakdown Spectroscopy for Determination of Magnesium Stearate in Pharmaceutical Powders and Solid Dosage Forms , 2005, Applied spectroscopy.

[13]  Weiyong. Li,et al.  Mass-balanced blend uniformity analysis of pharmaceutical powders by at-line near-infrared spectroscopy with a fiber-optic probe. , 2006, International journal of pharmaceutics.

[14]  D. T. Witte,et al.  Simple assessment of homogeneity in pharmaceutical mixing processes using a near-infrared reflectance probe and control charts. , 2006, Journal of pharmaceutical and biomedical analysis.

[15]  D. Massart,et al.  On-Line Monitoring of Powder Blending with Near-Infrared Spectroscopy , 1998 .

[16]  F. Clarke,et al.  Determination of the Information Depth and Sample Size for the Analysis of Pharmaceutical Materials Using Reflectance Near-Infrared Microscopy , 2002 .

[17]  L. Danielsson,et al.  Quantitative in-line monitoring of powder blending by near infrared reflection spectroscopy , 2002 .

[18]  Fernando J. Muzzio,et al.  Quantitative characterization of mixing of free-flowing granular material in tote (bin)-blenders , 2002 .

[19]  J. Drennen,et al.  A Process Analytical Technology approach to near-infrared process control of pharmaceutical powder blending. Part III: Quantitative near-infrared calibration for prediction of blend homogeneity and characterization of powder mixing kinetics. , 2006, Journal of pharmaceutical sciences.

[20]  P. K. Aldridge,et al.  On-line monitoring of powder blend homogeneity by near-infrared spectroscopy. , 1996, Analytical chemistry.

[21]  Vidya Swaminathan,et al.  Polydisperse Powder Mixtures: Effect of Particle Size and Shape on Mixture Stability , 2002, Drug development and industrial pharmacy.