This study demonstrates the performance improvement of an air-to-air roof top unit (RTU) achieved by optimizing an evaporator’s refrigerant circuitry using evolutionary algorithms. The subject of this study is a unit with a cooling capacity of 7.5 Tons (26.4 kW). The RTU employs two separate refrigerant cycles having separate compressors, condensers, and thermostatic expansion valves (TXV) but using a single evaporator slab in which two separate refrigerant circuits are implemented. We modified the RTU by replacing the refrigerant-to-air condensers with water cooled brazed plate heat exchangers in order to facilitate testing. Performance tests were conducted in a conditioned environmental chamber in line with AHRI standard 340/360-2007; in order to accomplish this, we maintained the liquid line saturation pressure and subcooling from the manufacturer’s test data by adjusting the condenser water flow rate and temperature. We also measured the in-situ air velocity profile using Particle Image Velocimetry (PIV), a non-intrusive, laser-based technique. The measurements showed that the range of air velocities passing through the heat exchanger varied from 0.5 ms to 3.0 ms, with the area weighted average of the measurements being 1.75 ms. The PIV data was used to generate a map of the air flow distribution through the heat exchanger, which served as the basis for refrigerant circuitry optimization. We simulated the performance of the original evaporator using the measured air velocity distribution and The National Institute of Standards and Technology’s (NIST) heat exchanger model, EVAP-COND, and tuned our computational model to exactly match the laboratory measurements. We then used the measured air velocity distribution with NIST’s evolutionary algorithm optimization module, Intelligent System for Heat Exchanger Design (ISHED), to redesign the evaporator circuitry. The
[1]
P. Domanski,et al.
Evaporator Optimization for Non-Uniform Air Distribution | NIST
,
2010
.
[2]
Barry N. Taylor,et al.
Guidelines for Evaluating and Expressing the Uncertainty of Nist Measurement Results
,
2017
.
[3]
M. Chwalowski,et al.
Verification of evaporator computer models and analysis of performance of an evaporator coil
,
1989
.
[4]
Kenneth A. Kaufman,et al.
A dual-mode evolutionary algorithm for designing optimized refrigerant circuitries for finned-tube heat exchangers
,
2011
.
[5]
PIOTR A. DOHANSKI.
Rating of Mixed Split Residential Air Conditioners
,
1988
.
[6]
David A. Yashar,et al.
EVAP-COND, Version 4.0; Simulation Models for Finned-Tube Heat Exchangers with Circuitry Optimization | NIST
,
2016
.
[7]
Piotr A. Domanski,et al.
Potential benefits of smart refrigerant distributors. Final report.
,
2003
.
[8]
L. Larsen,et al.
Comparison of fin-and-tube interlaced and face split evaporators with flow maldistribution and compensation
,
2013
.
[9]
David A Yashar,et al.
Air-Side Velocity Distribution in Finned-Tube Heat Exchangers | NIST
,
2007
.