Validity and Reliability of Mobile Applications for Assessing Strength, Power, Velocity, and Change-of-Direction: A Systematic Review

This systematic review aimed to (1) identify and summarize studies that have examined the validity of apps for measuring human strength, power, velocity, and change-of-direction, and (2) identify and summarize studies that have examined the reliability of apps for measuring human strength, power, velocity, and change-of-direction. A systematic review of Cochrane Library, EBSCO, PubMed, Scielo, Scopus, SPORTDiscus, and Web of Science databases was performed, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. From the 435 studies initially identified, 23 were fully reviewed, and their outcome measures were extracted and analyzed. In total, 11 mobile applications were analyzed and summarized for their validity and reliability to test movement velocity, movement time, movement displacement, power output, and workload. The present systematic review revealed that the tested apps are valid and reliable for measuring bar movement velocity during lower and upper body resistance exercises; however, systematic bias was detected with heavier loads.

[1]  A. Castillo-Rodríguez,et al.  Relationship Between Muscular Strength and Sprints with Changes of Direction , 2012, Journal of strength and conditioning research.

[2]  Nicholas D. Gilson,et al.  Measuring and Influencing Physical Activity with Smartphone Technology: A Systematic Review , 2014, Sports Medicine.

[3]  Amador García-Ramos,et al.  Reliability and concurrent validity of the Velowin optoelectronic system to measure movement velocity during the free-weight back squat , 2018, International Journal of Sports Science & Coaching.

[4]  Jeremy A. Moody,et al.  A Testing Battery for the Assessment of Fitness in Soccer Players , 2011 .

[5]  D Chollet,et al.  What is the Best Method for Assessing Lower Limb Force-Velocity Relationship? , 2014, International Journal of Sports Medicine.

[6]  Slobodan Jaric,et al.  Validity of a Linear Velocity Transducer for Testing Maximum Vertical Jumps. , 2017, Journal of applied biomechanics.

[7]  B. Morel,et al.  A Simple Method for Assessing Upper-Limb Force-Velocity Profile in Bench Press. , 2017, International journal of sports physiology and performance.

[8]  B. Drust,et al.  Reliability of “in-season” fitness assessments in youth elite soccer players: a working model for practitioners and coaches , 2018 .

[9]  Danica Janicijevic,et al.  Validity of the iLOAD® app for resistance training monitoring , 2019, PeerJ.

[10]  A. S. San Juan,et al.  Validity and Reliability of a Smartphone Accelerometer for Measuring Lift Velocity in Bench-Press Exercises , 2020, Sustainability.

[11]  Tomás T. Freitas,et al.  Estimation of maximum sprinting speed with timing gates: greater accuracy of 5-m split times compared to 10-m splits. , 2021, Sports biomechanics.

[12]  Harry G. Banyard,et al.  Validity of Various Methods for Determining Velocity, Force, and Power in the Back Squat. , 2017, International journal of sports physiology and performance.

[13]  P. Jiménez-Reyes,et al.  Validity and reliability of a low-cost digital dynamometer for measuring isometric strength of lower limb , 2017, Journal of sports sciences.

[14]  Neil E. Bezodis,et al.  Change of Direction and Agility Tests: Challenging Our Current Measures of Performance , 2017 .

[15]  R. Ross,et al.  A Systematic Review of Fitness Apps and Their Potential Clinical and Sports Utility for Objective and Remote Assessment of Cardiorespiratory Fitness , 2019, Sports Medicine.

[16]  Amador García-Ramos,et al.  Reliability and Concurrent Validity of Seven Commercially Available Devices for the Assessment of Movement Velocity at Different Intensities During the Bench Press , 2019, Journal of strength and conditioning research.

[17]  E. Hafen,et al.  Using smartphone accelerometer data to obtain scientific mechanical-biological descriptors of resistance exercise training , 2020, PloS one.

[18]  Kristof Kipp,et al.  Validity and reliability of a computer-vision-based smartphone app for measuring barbell trajectory during the snatch , 2020, Journal of sports sciences.

[19]  Robert Stanton,et al.  Validity of a Smartphone-Based Application for Determining Sprinting Performance , 2016, Journal of sports medicine.

[20]  Ernesto De la Cruz Sánchez,et al.  Validity of an inertial system to measure sprint time and sport task time: a proposal for the integration of photocells in an inertial system , 2017 .

[21]  A. García-Ramos,et al.  Assessment of the loaded squat jump and countermovement jump exercises with a linear velocity transducer: which velocity variable provides the highest reliability? , 2019, Sports biomechanics.

[22]  Eneko Larumbe-Zabala,et al.  Validity and reliability of a novel optoelectronic device to measure movement velocity, force and power during the back squat exercise , 2018, Journal of sports sciences.

[23]  Carlos Balsalobre-Fernández,et al.  Analysis of Wearable and Smartphone-Based Technologies for the Measurement of Barbell Velocity in Different Resistance Training Exercises , 2017, Front. Physiol..

[24]  Carlos Balsalobre-Fernández,et al.  Precision of 7 Commercially Available Devices for Predicting the Bench Press 1-Repetition Maximum From the Individual Load-Velocity Relationship. , 2019, International journal of sports physiology and performance.

[25]  A. Kilding,et al.  A Brief Review of Handgrip Strength and Sport Performance , 2017, Journal of strength and conditioning research.

[26]  C. Bishop,et al.  The validity and reliability of the My Jump 2 app for measuring the reactive strength index and drop jump performance. , 2019, The Journal of sports medicine and physical fitness.

[27]  A. García-Ramos,et al.  Reliability and Validity of the iLOAD Application for Monitoring the Mean Set Velocity During the Back Squat and Bench Press Exercises Performed Against Different Loads. , 2020, Journal of strength and conditioning research.

[28]  F. Saigí-Rubió,et al.  Using Mobile Applications to Increase Physical Activity: A Systematic Review , 2020, International journal of environmental research and public health.

[29]  D. Moher,et al.  Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement , 2009, BMJ : British Medical Journal.

[30]  Pierre Samozino,et al.  Interpreting Power-Force-Velocity Profiles for Individualized and Specific Training. , 2016, International journal of sports physiology and performance.

[31]  Alejandro Bastida Castillo,et al.  Validity of an inertial system to measure sprint time and sport task time: a proposal for the integration of photocells in an inertial system , 2017 .

[32]  J. J. González-Badillo,et al.  Reliability of technologies to measure the barbell velocity: Implications for monitoring resistance training , 2020, PloS one.

[33]  A. Faigenbaum,et al.  Squat and Bench Press Force-Velocity Profiling in Male and Female Adolescent Rugby Players. , 2019, Journal of strength and conditioning research.

[34]  Natalia Romero-Franco,et al.  Sprint performance and mechanical outputs computed with an iPhone app: Comparison with existing reference methods , 2017, European journal of sport science.

[35]  Chris Bishop,et al.  The validity and reliability of a novel app for the measurement of change of direction performance , 2019, Journal of sports sciences.

[36]  Bas Van Hooren The Difference Between Countermovement and Squat Jump Performances , 2019 .

[37]  V. Yingling,et al.  The reliability of vertical jump tests between the Vertec and My Jump phone application , 2018, PeerJ.

[38]  I. Zuoziene,et al.  Field-Based Tests for the Assessment of Physical Fitness in Children and Adolescents Practicing Sport: A Systematic Review within the ESA Program , 2019, Sustainability.

[39]  K A Schmidtke,et al.  Tracking physical activity using smart phone apps: assessing the ability of a current app and systematically collecting patient recommendations for future development , 2020, BMC Medical Informatics Decis. Mak..

[40]  Robert Stanton,et al.  Validity and intra-rater reliability of MyJump app on iPhone 6s in jump performance. , 2017, Journal of science and medicine in sport.

[41]  S. Dorel,et al.  A simple method for measuring power, force, velocity properties, and mechanical effectiveness in sprint running , 2016, Scandinavian journal of medicine & science in sports.

[42]  Enrique Herrera-Viedma,et al.  Smartphone Applications to Perform Body Balance Assessment: a Standardized Review , 2018, Journal of Medical Systems.

[43]  Juan José González-Badillo,et al.  Reproducibility and Repeatability of Five Different Technologies for Bar Velocity Measurement in Resistance Training , 2019, Annals of Biomedical Engineering.

[44]  C. Balsalobre-Fernández,et al.  The validity and reliability of an iPhone app for measuring vertical jump performance , 2015, Journal of sports sciences.

[45]  R. Ramírez-Campillo,et al.  Intersession and Intrasession Reliability and Validity of the My Jump App for Measuring Different Jump Actions in Trained Male and Female Athletes , 2016, Journal of strength and conditioning research.

[46]  L. Capranica,et al.  Tests for the Assessment of Sport-Specific Performance in Olympic Combat Sports: A Systematic Review With Practical Recommendations , 2018, Front. Physiol..

[47]  S. Jaric,et al.  A simple method for assessment of muscle force, velocity, and power producing capacities from functional movement tasks , 2017, Journal of sports sciences.

[48]  S. Jaric,et al.  Assessment of leg muscles mechanical capacities: Which jump, loading, and variable type provide the most reliable outcomes? , 2017, European journal of sport science.

[49]  P. Jiménez-Reyes,et al.  Do you Play or Do you Train? Insights From Individual Sports for Training Load and Injury Risk Management in Team Sports Based on Individualization , 2020, Frontiers in Physiology.

[50]  E. Tønnessen,et al.  Sprint Time Differences Between Single- and Dual-Beam Timing Systems , 2014, Journal of strength and conditioning research.

[51]  Stuart J. Cormack,et al.  Strength and Power Profiling of Athletes: Selecting Tests and How to Use the Information for Program Design , 2013 .

[52]  Marco Donati,et al.  1RM prediction: a novel methodology based on the force–velocity and load–velocity relationships , 2016, European Journal of Applied Physiology.

[53]  G. Altavilla,et al.  Assessment of Sport Performance: Theoretical Aspects and Practical Indications , 2019, Sport Mont.

[54]  U. Albrecht,et al.  Potentials of Digitalization in Sports Medicine: A Narrative Review. , 2020, Current sports medicine reports.

[55]  William Johnston,et al.  Wearable Inertial Sensor Systems for Lower Limb Exercise Detection and Evaluation: A Systematic Review , 2018, Sports Medicine.

[56]  D. Stefanyshyn,et al.  Validity of a portable force platform for assessing biomechanical parameters in three different tasks , 2017, Sports biomechanics.

[57]  Carlo Castagna,et al.  Dose-response relationship of autonomic nervous system responses to individualized training impulse in marathon runners. , 2009, American journal of physiology. Heart and circulatory physiology.

[58]  Edward R Brooks,et al.  Novel Technologies Found to be Valid and Reliable for the Measurement of Vertical Jump Height With Jump-and-Reach Testing , 2018, Journal of strength and conditioning research.

[59]  Mário Rodrigues,et al.  Mobile Apps to Quantify Aspects of Physical Activity: a Systematic Review on its Reliability and Validity , 2020, Journal of Medical Systems.

[60]  Carlos Balsalobre-Fernández,et al.  Validity and reliability of a novel iPhone app for the measurement of barbell velocity and 1RM on the bench-press exercise , 2018, Journal of sports sciences.

[61]  Jean-Benoit Morin,et al.  The Validity and Reliability of an iPhone App for Measuring Running Mechanics. , 2017, Journal of applied biomechanics.

[62]  I. Loturco,et al.  Maximum acceleration performance of professional soccer players in linear sprints: Is there a direct connection with change-of-direction ability? , 2019, PloS one.

[63]  Javier Courel-Ibáñez,et al.  Are we ready to measure running power? Repeatability and concurrent validity of five commercial technologies , 2020, European journal of sport science.

[64]  F. Nakamura,et al.  Predicting the Maximum Dynamic Strength in Bench Press: The High Precision of the Bar Velocity Approach , 2017, Journal of strength and conditioning research.

[65]  M. Adamakis Comparing the Validity of a GPS Monitor and a Smartphone Application to Measure Physical Activity , 2017 .

[66]  Ben Schram,et al.  Reliability and validity of clinically accessible smartphone applications to measure joint range of motion: A systematic review , 2019, PloS one.

[67]  Peter D. Mundy,et al.  Concurrent Validity of a Portable Force Plate Using Vertical Jump Force-Time Characteristics. , 2018, Journal of applied biomechanics.

[68]  Mikael Forsman,et al.  An iPhone application for upper arm posture and movement measurements. , 2017, Applied ergonomics.

[69]  C. Twist,et al.  Criterion and Construct Validity of an Isometric Midthigh-Pull Dynamometer for Assessing Whole-Body Strength in Professional Rugby League Players. , 2017, International journal of sports physiology and performance.

[70]  Steve W. Thompson,et al.  The Reliability and Validity of Current Technologies for Measuring Barbell Velocity in the Free-Weight Back Squat and Power Clean , 2020, Sports.

[71]  Carlos Balsalobre-Fernández,et al.  Use of Mobile Applications to Collect Data in Sport, Health, and Exercise Science: A Narrative Review. , 2017, Journal of strength and conditioning research.