Principle and Application of Asynchronous Operation of China Southern Power Grid

The instability induced by high voltage direct current (HVdc) contingencies is challenging operation of ac/dc synchronous system. The asynchronization of ac/dc synchronous system can be a promising strategy for this concern which, however, is lack of practical applications. This paper analyzed the necessity of replacing the existing parallel ac/dc interconnection by pure dc interconnection in China Southern Power Grid (CSG), Guangzhou, China. A comprehensive solution is proposed to mitigate the risk of frequency instability in a small power grid with large amount of power sending out by HVdcs. Meanwhile, the strategy that combines the use of line-commuted converter-HVdc, voltage source converter-HVdc, and flexible ac transmission system is proposed to ensure the secure operation of HVdc feeding in weak ac system. The principle and application of asynchronous operation of CSG provide a reference for other grid development.

[1]  Yang Wei SPECIAL ISSUES AND SUGGESTIONS ON MULTI INFEED AC/DC POWER SYSTEMS , 2000 .

[2]  Qi Da-cai Analysis of the Large Disturbances Caused by Cascading Failures and Defense Schemes in CSG , 2010 .

[3]  Kun Yuan,et al.  Disturbance rejection-based LFC for multi-area parallel interconnected AC/DC system , 2016 .

[4]  Rao Hong The Index Parameters for Analyzing Multi-infeed HVDC Systems and Their Applications , 2008 .

[5]  Van Tu Dao,et al.  An approach to online asynchronous mode prevention in two-area power systems , 2014, 2014 IEEE 27th Canadian Conference on Electrical and Computer Engineering (CCECE).

[6]  E. V. Larsen,et al.  Parallel AC/DC transmission lines steady-state induction issues , 1989 .

[7]  A. Gavrilovic,et al.  AC/DC system strength as indicated by short circuit ratios , 1991 .

[8]  Liu Miao The Risks Analysis and Defensive Measures Research of Cascading Failures in China Southern Power Grid , 2010 .

[9]  Jizhong Zhu,et al.  Loss-Minimizing Generation Unit and Tie-Line Scheduling for Asynchronous Interconnection , 2018, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[10]  Hong Chao Simulation Analysis on the Commutation Failure and Power Recovery Characteristic of an Actual DC Transmission System , 2011 .

[11]  Jin Xiaoming HVDC-interaction-strength Index for the Multi-infeed-HVDC Power System , 2009 .

[12]  P. Kundur,et al.  Power system stability and control , 1994 .

[13]  C. W. Taylor,et al.  HVDC controls for system dynamic performance , 1991 .

[14]  Moses Peter Musau,et al.  Asynchronous interconnection of the proposed East Africa Power Pool (EAPP) , 2017, 2017 IEEE PES PowerAfrica.