A Doppler-two-dimensional echocardiographic method for quantitation of mitral regurgitation.

A noninvasive method to accurately quantitate the severity of mitral insufficiency would be of major clinical value. In theory, in the absence of confounding variables, regurgitant mitral flow should represent the difference between forward mitral blood flow and aortic blood flow. Since Doppler-two-dimensional echocardiographic (D2DE) methods for measuring transvalvular mitral and aortic flow have been validated, it should be possible to use mitral and aortic flows derived by this method to calculate regurgitant mitral flow. To assess the validity and accuracy of this combined approach for quantitation of regurgitant flow, we developed an open-chest canine preparation in which we could simulate, vary, and accurately measure degrees of mitral regurgitation. Seven animals were anesthetized and prepared to allow controlled right heart output. Mitral regurgitation was than simulated by placing a flexible conduit incorporating a one-way valve and electromagnetic flowmeter between the left ventricular apex and left atrium. Flow through the tube (effective mitral regurgitation) was varied between 0.2 and 1.8 liters/min and forward cardiac output ranged between 0.5 and 4 liters/min. Transmitral and transaortic flows were calculated by previously reported Doppler methods. Doppler-derived estimates of forward flow through the aortic valve correlated well with the flow measured by flowmeter (r = .92), and regurgitant flow and regurgitant fraction calculated by the D2DE approach also compared well with those measured by flowmeter (r = .84 and .83, respectively). This study demonstrates that mitral regurgitant flow and regurgitant fraction calculated by the D2DE method provide an acceptable measure of both absolute regurgitant flow and the regurgitant fraction in the experimental setting.

[1]  R. Miller,et al.  Assessment of pulsed Doppler echocardiography in detection and quantification of aortic and mitral regurgitation. , 1980, British heart journal.

[2]  A. Weyman,et al.  Variable effects of changes in flow rate through the aortic, pulmonary and mitral valves on valve area and flow velocity: impact on quantitative Doppler flow calculations. , 1985, Journal of the American College of Cardiology.

[3]  D J Sahn,et al.  The Effect of Variations on Pulsed Doppler Sampling Site on Calculation of Cardiac Output: An Experimental Study in Open‐chest Dogs , 1983, Circulation.

[4]  G. Rowe,et al.  Detection and estimation of rheumatic mitral regurgitation in the presence of mitral stenosis by pulsed Doppler echocardiography. , 1983, The American journal of cardiology.

[5]  D. Kalmanson,et al.  Pulsed Doppler echocardiographic indices for assessing mitral regurgitation. , 1984, British heart journal.

[6]  S. Goldberg,et al.  Clinical utility of two-dimensional doppler echocardiographic techniques for estimating pulmonary to systemic blood flow ratios in children with left to right shunting atrial septal defect, ventricular septal defect or patent ductus arteriosus. , 1984, Journal of the American College of Cardiology.

[7]  L. Becker,et al.  Measurement of Aortic and Mitral Regurgitation by Gated Cardiac Blood Pool Scan , 1979, Circulation.

[8]  S. Goldberg,et al.  A pulsed Doppler echocardiographic method for calculation of pulmonary and systemic flow: accuracy in a canine model with ventricular septal defect. , 1983, Circulation.

[9]  S. Goldberg,et al.  Evaluation of pulmonary and systemic blood flow by 2-dimensional Doppler echocardiography using fast Fourier transform spectral analysis. , 1982, The American journal of cardiology.

[10]  Richard J. Jones Heart Disease: A Textbook of Cardiovascular Medicine , 1980 .

[11]  D. Decristofaro,et al.  Detection and Estimation of the Degree of Mitral Regurgitation by Range‐gated Pulsed Doppler Echocardiography , 1980, Circulation.

[12]  E. Braunwald,et al.  Hemodynamic Effects of Quantitatively Varied Experimental Mitral Regurgitation , 1957, Circulation research.

[13]  S. Goldberg,et al.  A two-dimensional Doppler echocardiographic method for calculation of pulmonary and systemic blood flow in a canine model with a variable-sized left-to-right extracardiac shunt. , 1983, Circulation.

[14]  S. Goldberg,et al.  The Mitral Valve Orifice Method for Noninvasive Two‐dimensional Echo Doppler Determinations of Cardiac Output , 1983, Circulation.

[15]  C. Lillehei,et al.  LEFT RETROGRADE CARDIOANGIOGRAPHY IN ACQUIRED CARDIAC DISEASE: TECHNIC, INDICATIONS AND INTERPRETATIONS IN 700 CASES. , 1964, The American journal of cardiology.