Utility of pulse oximetry in the detection of arterial hypoxemia in liver transplant candidates

Hepatopulmonary syndrome, arterial hypoxemia caused by intrapulmonary vasodilatation, occurs in approximately 10% of patients with cirrhosis. The severity of hypoxemia affects liver transplant candidacy and is associated with increased morbidity and mortality posttransplantation. Screening guidelines for detecting the presence of arterial hypoxemia do not exist. The aim of this study is to investigate the accuracy and utility of pulse oximetry in the detection of hypoxemia (PaO2 < 70 mm Hg) in patients with cirrhosis. Two hundred prospective liver transplant candidates were compared with 94 controls. Arterial oxyhemoglobin saturation was obtained by pulse oximetry (SpO2) and compared with simultaneous arterial blood gas (ABG) oxyhemoglobin values (SaO2; bias = the difference). PaO2, carboxyhemoglobin, methemoglobin, and routine clinical and biochemical parameters were investigated to account for the bias. SpO2 overestimated SaO2 in 98% of patients with cirrhosis (mean bias, 3.37%; range, −1% to 10%). Forty‐four percent of patients with cirrhosis and controls had a bias of 4% or greater. No clinical or biochemical parameters of cirrhosis accounted for the overestimation of pulse oximetry. Twenty‐five subjects with cirrhosis were hypoxemic, and an SpO2 of 97% or less showed a sensitivity of 96% and a positive likelihood ratio of 3.9 for detecting hypoxemia. An SpO2 of 94% or less detected all subjects with an arterial PaO2 less than 60 mm Hg. Pulse oximetry significantly overestimates arterial oxygenation, and the inaccuracy is not influenced by liver disease. Nevertheless, pulse oximetry can be a useful screening tool to detect arterial hypoxemia in patients with cirrhosis, but a higher threshold for obtaining an ABG must be used.

[1]  R. Wiesner,et al.  Hepatopulmonary syndrome with progressive hypoxemia as an indication for liver transplantation: case reports and literature review. , 1997, Mayo Clinic proceedings.

[2]  C. Jaffe,et al.  Diagnostic utility of contrast echocardiography and lung perfusion scan in patients with hepatopulmonary syndrome. , 1995, Gastroenterology.

[3]  P. Batra,et al.  Pulmonary dysfunction in advanced liver disease: frequent occurrence of an abnormal diffusing capacity. , 1991, The American journal of medicine.

[4]  Heikki Palve,et al.  Accuracy of three pulse oximeters at low cardiac index and peripheral temperature , 1991, Critical care medicine.

[5]  J. Roca,et al.  The hepatopulmonary syndrome: new name, old complexities. , 1992, Thorax.

[6]  N. Nanda,et al.  Use of macroaggregated albumin lung perfusion scan to diagnose hepatopulmonary syndrome: a new approach. , 1998, Gastroenterology.

[7]  C. Hanning,et al.  Comparison of pulse oximeters: effects of vasoconstriction and venous engorgement. , 1989, British journal of anaesthesia.

[8]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[9]  N. Ettinger,et al.  Pulmonary complications of liver transplantation. , 1996, Clinics in chest medicine.

[10]  J. Sinex Pulse oximetry: principles and limitations. , 1999, The American journal of emergency medicine.

[11]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[12]  L. Jensen,et al.  Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults. , 1998, Heart & lung : the journal of critical care.

[13]  Beth Atkinson,et al.  A prospective study of pulmonary function and gas exchange following liver transplantation. , 1992, Chest.

[14]  S J Barker,et al.  Effects of anemia on pulse oximetry and continuous mixed venous hemoglobin saturation monitoring in dogs. , 1991, Anesthesiology.

[15]  T. Clerbaux,et al.  Hyperbilirubinemia does not interfere with hemoglobin saturation measured by pulse oximetry. , 1989, Anesthesiology.