Comparative evaluation of current injection based islanding detection methods for distributed generation systems

Anti-islanding (AI) function is a necessity for distributed generation systems. Current injection based AI methods have been widely used. However, too small current injection may fail to detect the islanding, while too large current injection will lead to the disturbance and poor power quality. On the other hand, d-axis or q-axis current injection can be used, and one may wonder which is preferred? Therefore, this paper presents a quantitative analysis of them from the performance comparative viewpoint. It is expected to provide a helpful guidance for designing the effective AI function for distributed generation systems.

[1]  Zhihong Ye,et al.  Investigation of antiislanding protection of power converter based distributed generators using frequency domain analysis , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[2]  Emilio Figueres,et al.  Review of anti-islanding techniques in distributed generators , 2010 .

[3]  Ajeet Rohatgi,et al.  Analysis and performance assessment of the active frequency drift method of islanding prevention , 1999 .

[4]  Kwang-Ho Kim,et al.  An islanding detection method for distributed generations using voltage unbalance and total harmonic distortion of current , 2004 .

[5]  R. Iravani,et al.  Negative-Sequence Current Injection for Fast Islanding Detection of a Distributed Resource Unit , 2008, IEEE Transactions on Power Electronics.

[6]  J.L. Kirtley,et al.  Performance of the OVP/UVP and OFP/UFP Method With Voltage and Frequency Dependent Loads , 2009, IEEE Transactions on Power Delivery.

[7]  Ajeet Rohatgi,et al.  Determining the relative effectiveness of islanding detection methods using phase criteria and nondetection zones , 2000 .

[8]  S. Kennedy,et al.  Sandia Frequency-Shift Parameter Selection to Eliminate Nondetection Zones , 2009, IEEE Transactions on Power Delivery.

[9]  M. Liserre,et al.  Overview of Anti-Islanding Algorithms for PV Systems. Part I: Passive Methods , 2006, 2006 12th International Power Electronics and Motion Control Conference.

[10]  M.H. Nehrir,et al.  A Hybrid Islanding Detection Technique Using Voltage Unbalance and Frequency Set Point , 2007, IEEE Transactions on Power Systems.

[11]  Xiaoyu Wang,et al.  Impact of Positive-Feedback Anti-Islanding Methods on Small-Signal Stability of Inverter-Based Distributed Generation , 2008, IEEE Transactions on Energy Conversion.

[12]  H.H. Zeineldin,et al.  A $Q$– $f$ Droop Curve for Facilitating Islanding Detection of Inverter-Based Distributed Generation , 2009, IEEE Transactions on Power Electronics.

[13]  Xinchun Lin,et al.  Improved SMS islanding detection method for grid-connected converters , 2010 .

[14]  Yongzheng Zhang,et al.  Islanding Detection Assessment of Multi-Inverter Systems With Active Frequency Drifting Methods , 2008, IEEE Transactions on Power Delivery.

[15]  P.N. Enjeti,et al.  Development of a robust anti-islanding algorithm for utility interconnection of distributed fuel cell powered generation , 2004, IEEE Transactions on Power Electronics.

[16]  Marco Liserre,et al.  Wavelet-Based Islanding Detection in Grid-Connected PV Systems , 2009, IEEE Transactions on Industrial Electronics.

[17]  P.N. Enjeti,et al.  Development of a robust antiislanding algorithm for utility interconnection of distributed fuel cell powered generation , 2004, Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04..

[18]  Marco Liserre,et al.  An Anti-Islanding Method for Single-Phase Inverters Based on a Grid Voltage Sensorless Control , 2006, IEEE Transactions on Industrial Electronics.

[19]  Stephen J. Finney,et al.  Harmonic distortion-based island detection technique for inverter-based distributed generation , 2009 .

[20]  L.A.C. Lopes,et al.  Performance assessment of active frequency drifting islanding detection methods , 2006, IEEE Transactions on Energy Conversion.

[21]  Mikihiko Matsui,et al.  A review of current anti-islanding methods for photovoltaic power system , 2010 .

[22]  Wilsun Xu,et al.  Impact of DG Interface Controls on the Sandia Frequency Shift Antiislanding Method , 2007, IEEE Transactions on Energy Conversion.

[23]  J.L. Kirtley,et al.  A Simple Technique for Islanding Detection With Negligible Nondetection Zone , 2009, IEEE Transactions on Power Delivery.

[24]  V. John,et al.  Investigation of anti-islanding protection of power converter based distributed generators using frequency domain analysis , 2004, IEEE Transactions on Power Electronics.

[25]  Xiaoyu Wang Investigation of positive feedback anti-islanding control for multiple inverter-based distributed generators , 2009, 2009 IEEE Power & Energy Society General Meeting.