Multidimensional thermal mapping during radiofrequency ablation treatments with minimally invasive fiber optic sensors.

Temperature mapping is a key asset in supporting the clinician during thermal ablation (TA) treatment of tumors without adding additional risk to the TA procedure. Herein we report our experiments on multidimensional thermal mapping during radio frequency (RF) thermal ablation treatments of an ex-vivo animal organ. The temperature was monitored using several arrays of fiber Bragg gratings properly positioned around the RF applicator. The results show the effectiveness of our proposed method at assessing the TA probe depth and demonstrating how the insertion depth directly influences the maximum temperature and the treated area of the radio frequency ablation.

[1]  R. Leveillee,et al.  First prize: direct real-time temperature monitoring for laparoscopic and CT-guided radiofrequency ablation of renal tumors between 3 and 5 cm. , 2007, Journal of endourology.

[2]  Alfredo Cigada,et al.  Fiber-Optic Temperature and Pressure Sensors Applied to Radiofrequency Thermal Ablation in Liver Phantom: Methodology and Experimental Measurements , 2015, J. Sensors.

[3]  N. Habib,et al.  Clinical short-term results of radiofrequency ablation in primary and secondary liver tumors. , 1999, American journal of surgery.

[4]  Elfed Lewis,et al.  Fiber-optic chirped FBG for distributed thermal monitoring of ex-vivo radiofrequency ablation of liver. , 2014, Biomedical optics express.

[5]  Agostino Iadicicco,et al.  Temperature profile of ex-vivo organs during radio frequency thermal ablation by fiber Bragg gratings , 2016, Journal of biomedical optics.

[6]  Christopher L Brace,et al.  Principles of and advances in percutaneous ablation. , 2011, Radiology.

[7]  E. Samset,et al.  Temperature measurement in soft tissue using a distributed fibre Bragg-grating sensor system , 2001, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[8]  D. Panescu,et al.  Three-dimensional finite element analysis of current density and temperature distributions during radio-frequency ablation , 1995, IEEE Transactions on Biomedical Engineering.

[9]  Sergio Silvestri,et al.  Optical-Fiber Measurement Systems for Medical Applications , 2011 .

[10]  A. Ravaud,et al.  Midterm local efficacy and survival after radiofrequency ablation of lung tumors with minimum follow-up of 1 year: prospective evaluation. , 2006, Radiology.

[11]  Emiliano Schena,et al.  Multipoint temperature monitoring in liver undergoing computed tomography-guided radiofrequency ablation with fiber Bragg grating probes , 2016, 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[12]  G. Gazelle,et al.  Thermal ablation therapy for focal malignancy: a unified approach to underlying principles, techniques, and diagnostic imaging guidance. , 2000, AJR. American journal of roentgenology.

[13]  Yuman Fong,et al.  American Society of Clinical Oncology 2009 clinical evidence review on radiofrequency ablation of hepatic metastases from colorectal cancer. , 2010, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[14]  Louis R Kavoussi,et al.  Infrared thermography and thermocouple mapping of radiofrequency renal ablation to assess treatment adequacy and ablation margins. , 2003, Urology.

[15]  Huacai Chen,et al.  Study on Optical Fiber Bragg Grating Temperature Sensors for Human Body Temperature Monitoring , 2012, 2012 Symposium on Photonics and Optoelectronics.

[16]  Elfed Lewis,et al.  Optical fiber sensors-based temperature distribution measurement in ex vivo radiofrequency ablation with submillimeter resolution , 2014, Journal of biomedical optics.

[17]  Mathieu Pernot,et al.  The link between tissue elasticity and thermal dose in vivo , 2011, Physics in medicine and biology.

[18]  Dieter Haemmerich,et al.  Biophysics of radiofrequency ablation. , 2010, Critical reviews in biomedical engineering.

[19]  G. Maddern,et al.  Radiofrequency ablation of liver tumors: a systematic review. , 2006, Archives of surgery.

[20]  Elfed Lewis,et al.  Monitoring of radiofrequency thermal ablation in liver tissue through fibre Bragg grating sensors array , 2014 .

[21]  Elfed Lewis,et al.  Fiber Optic Sensors for Temperature Monitoring during Thermal Treatments: An Overview , 2016, Sensors.

[22]  R. Uzzo,et al.  Cryoablation or radiofrequency ablation of the small renal mass , 2008, Cancer.

[23]  J. McGahan,et al.  Radiofrequency ablation of the liver: current status. , 2001, AJR. American journal of roentgenology.

[24]  Sergio Silvestri,et al.  Techniques for temperature monitoring during laser-induced thermotherapy: An overview , 2013, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[25]  J A Zagzebski,et al.  Ultrasound monitoring of temperature change during radiofrequency ablation: preliminary in-vivo results. , 2002, Ultrasound in medicine & biology.