Gait and Dynamic Balance Sensing Using Wearable Foot Sensors

Remote monitoring of gait performance offers possibilities for objective evaluation and tackling impairment in motor ability, gait, and balance in populations, such as elderly, stroke, multiple sclerosis, and Parkinson’s. This requires a wearable and unobtrusive system capable of estimating ambulatory gait and balance measures, such as the extrapolated center of mass (XCoM) and dynamicmargin of stability. These estimations require the knowledge of 3-D forces and moments (F&M) and accurate foot positions. Though an existing ambulatory gait and balance system (AGBS) consisting of 3-D F&M sensors and inertial measurement units can be used for the purpose, it is bulky and conspicuous. Resistive pressure sensorswere investigated as an alternative to the onboard 3-D F&M sensors. Subject-specific regression models were built to estimate 3-D F&M from 1-D plantar pressures. The model was applicable for different walking speeds. Different pressure sensor configurations were studied to optimize the system complexity and accuracy. Using resistive sensors only under the toe and heel, we were able to estimate the XCoM with a mean absolute rms error of 2.2 ±0.3 cm in the walking direction while walking at a preferred speed, when compared to the AGBS. For the same case, the XCoM was classified as ahead or behind the base of support correctly at 97.7±1.7%. In conclusion, this paper shows that pressure sensors, minimally under the heel and toe, offer a lightweight and inconspicuous alternative for F&M sensing, toward estimating ambulatory gait and dynamic balance.

[1]  Hans H.C.M. Savelberg,et al.  Assessment of the horizontal, fore-aft component of the ground reaction force from insole pressure patterns by using artificial neural networks , 1999 .

[2]  Mark de Zee,et al.  Estimation of Ground Reaction Forces and Moments During Gait Using Only Inertial Motion Capture , 2016, Sensors.

[3]  Seung Eel Oh,et al.  Predicting Complete Ground Reaction Forces and Moments During Gait With Insole Plantar Pressure Information Using a Wavelet Neural Network. , 2015, Journal of biomechanical engineering.

[4]  Edwin van Asseldonk,et al.  Ambulatory Estimation of Center of Mass Displacement During Walking , 2009, IEEE Transactions on Biomedical Engineering.

[5]  P. Veltink,et al.  Ambulatory Estimation of Relative Foot Positions by Fusing Ultrasound and Inertial Sensor Data , 2015, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[6]  P. Veltink,et al.  Evaluation of instrumented shoes for ambulatory assessment of ground reaction forces. , 2007, Gait & posture.

[7]  Michael Ernst,et al.  Validity and reliability of pressure-measurement insoles for vertical ground reaction force assessment in field situations. , 2016, Applied ergonomics.

[8]  Petrus H. Veltink,et al.  Ambulatory Estimation of XCoM using Pressure Insoles and IMUs , 2018 .

[9]  B. Dobkin Rehabilitation after Stroke , 2005 .

[10]  A L Hof,et al.  The condition for dynamic stability. , 2005, Journal of biomechanics.

[11]  D. Howard,et al.  Whole body inverse dynamics over a complete gait cycle based only on measured kinematics. , 2008, Journal of biomechanics.

[12]  Edward Sazonov,et al.  A Comparative Review of Footwear-Based Wearable Systems , 2016 .

[13]  Peter H. Veltink,et al.  Ambulatory Assessment of Ankle and Foot Dynamics , 2007, IEEE Transactions on Biomedical Engineering.

[14]  Rezaul K. Begg,et al.  Foot Plantar Pressure Measurement System: A Review , 2012, Sensors.

[15]  P. Veltink,et al.  Ambulatory measurement of ground reaction forces , 2005 .

[16]  D. Roetenberg,et al.  Xsens MVN: Full 6DOF Human Motion Tracking Using Miniature Inertial Sensors , 2009 .

[17]  H Martin Schepers,et al.  Analysis of Balance during Functional Walking in Stroke Survivors , 2016, PloS one.

[18]  F C T van der Helm,et al.  Use of pressure insoles to calculate the complete ground reaction forces. , 2004, Journal of biomechanics.

[19]  Michele Caldara,et al.  A proximity sensor for the measurement of the inter-foot distance in static and dynamic tasks , 2016 .

[20]  Jaap H. Buurke,et al.  Ambulatory assessment of walking balance after stroke using instrumented shoes , 2016, Journal of NeuroEngineering and Rehabilitation.

[21]  A. Hof Scaling gait data to body size , 1996 .

[22]  Kai-Ming Chan,et al.  Estimating the complete ground reaction forces with pressure insoles in walking. , 2008, Journal of biomechanics.

[23]  Petrus H. Veltink,et al.  Pressure Insoles for Gait and Balance Estimation , 2017 .

[24]  Leonid Churilov,et al.  Consensus Standardized measurement of sensorimotor recovery in stroke trials : Consensus-based core recommendations from the Stroke Recovery and Rehabilitation Roundtable , 2017 .

[25]  K Aminian,et al.  Ambulatory assessment of 3D ground reaction force using plantar pressure distribution. , 2010, Gait & posture.

[26]  P. Beek,et al.  Assessing the stability of human locomotion: a review of current measures , 2013, Journal of The Royal Society Interface.