Rapid tandem-column micro-gas chromatography based on optofluidic ring resonators with multi-point on-column detection.

We demonstrated a novel tandem-column micro-gas chromatography (microGC) based on optofluidic ring resonator (OFRR). The OFRR is a thin-walled fused silica capillary whose interior surface is coated with a polymeric stationary phase. The circular cross section of the OFRR forms the micro-ring resonator and supports whispering gallery modes (WGMs). Via tapered optical fibers in contact with the OFRR, the WGM can be excited externally at any positions along the OFRR capillary, thus enabling multi-point, on-column, real-time detection of vapor molecules flowing through the OFRR. In the present OFRR-based tandem-column-based microGC implementation, a 180 cm long conventional GC column coated with a nonpolar stationary phase was followed by a relatively short OFRR column coated with a polar phase. Two detection positions, one at the inlet of the OFRR and the other a few centimeters downstream, were used to monitor the separation achieved by the first and the second column, respectively. Owing to the multi-point on-column detection that provides complementary retention time information on each chemical compound, co-eluted analytes can be well separated and identified on at least one detection channel and no modulation is needed at the interface of tandem columns. Separation and detection of twelve analytes with various volatilities and polarities within four minutes were demonstrated. In addition, the chromatograms obtained from three different locations along the OFRR column demonstrated the system's capability of on-column monitoring of the separation process for the target analyte in a vapor mixture. Our results will lead to the development of a rapid, simple, and portable microGC system with significantly improved selectivity and chemical identification capabilities.

[1]  Chia-Jung Lu,et al.  Portable gas chromatograph with tunable retention and sensor array detection for determination of complex vapor mixtures. , 2003, Analytical chemistry.

[2]  Vladimir S. Ilchenko,et al.  Optical microsphere resonators: optimal coupling to high-Q whispering-gallery modes , 1999 .

[3]  R. Sacks,et al.  Stop-flow programmable selectivity with a dual-column ensemble of microfabricated etched silicon columns and air as carrier gas. , 2005, Analytical chemistry.

[4]  A. Campillo,et al.  Optical processes in microcavities , 1996 .

[5]  Jing Liu,et al.  Optofluidic ring resonator sensors for rapid DNT vapor detection. , 2009, The Analyst.

[6]  Masoud Agah,et al.  Design, fabrication, and evaluation of microfabricated columns for gas chromatography. , 2004, Analytical chemistry.

[7]  R. Sacks,et al.  High-performance, static-coated silicon microfabricated columns for gas chromatography. , 2006, Analytical chemistry.

[8]  Jeffrey R. Jones,et al.  Prediction of retention times in serially linked open-tubular gas chromatographic columns and optimization of column lengths , 1990 .

[9]  P. Leonards,et al.  GC×GC-ECD: a promising method for the determination of dioxins and dioxin-like PCBs in food and feed , 2008, Analytical and bioanalytical chemistry.

[10]  D. R. Deans,et al.  Gas chromatographic columns with adjustable separation characteristics , 1973 .

[11]  Xudong Fan,et al.  Analysis of ring resonators for chemical vapor sensor development. , 2008, Optics express.

[12]  R. Sacks,et al.  Pulsed flow modulation for high-speed GC using a pressure-tunable column ensemble. , 2001, Analytical Chemistry.

[13]  Masoud Agah,et al.  Temperature-programmed GC using silicon microfabricated columns with integrated heaters and temperature sensors. , 2007, Analytical chemistry.

[14]  Yu-Chong Tai,et al.  Design, fabrication and characterization of monolithic embedded parylene microchannels in silicon substrate. , 2006, Lab on a chip.

[15]  K. Wise,et al.  First-generation hybrid MEMS gas chromatograph. , 2005, Lab on a chip.

[16]  Jost Goettert,et al.  Fabrication of micro-gas chromatograph columns for fast chromatography , 2006 .

[17]  Hongying Zhu,et al.  On-column micro gas chromatography detection with capillary-based optical ring resonators. , 2008, Analytical chemistry.

[18]  S. Terry,et al.  A gas chromatographic air analyzer fabricated on a silicon wafer , 1979, IEEE Transactions on Electron Devices.

[19]  R. Sacks,et al.  Pressure-Tunable Selectivity for High-Speed Gas Chromatography , 1994 .

[20]  A. Noy,et al.  Ultrafast gas chromatography on single-wall carbon nanotube stationary phases in microfabricated channels. , 2006, Analytical chemistry.

[21]  Xudong Fan,et al.  Rapid chemical-vapor sensing using optofluidic ring resonators. , 2008, Optics letters.

[22]  K. Ward,et al.  Immobilization of cytochrome c oxidase into electrode-supported lipid bilayer membranes for in vitro cytochrome c sensing , 2006, IEEE Sensors Journal.

[23]  Keith R Cadwallader,et al.  Micromachined GC columns for fast separation of organophosphonate and organosulfur compounds. , 2008, Analytical chemistry.

[24]  J. M. Bauer,et al.  Recent advancements in the gas-phase MicroChemLab , 2006, IEEE Sensors Journal.

[25]  Steven K. Showalter,et al.  Microfabricated thermal conductivity detector for the micro-ChemLab™ , 2005 .

[26]  Xudong Fan,et al.  Liquid-core optical ring-resonator sensors. , 2006, Optics letters.

[27]  J. Purnell,et al.  Separation of aliphatic hydrocarbon mixtures by gas chromatography using serial liquid-phase and solid-phase columns , 1991 .

[28]  E. Zellers,et al.  Multiple-stage microfabricated preconcentrator-focuser for micro gas chromatography system , 2005, Journal of Microelectromechanical Systems.

[29]  Richard Sacks,et al.  Selectivity enhancement for high-speed GC analysis of volatile organic compounds with portable instruments designed for vacuum-outlet and atmospheric-pressure inlet operation using air as the carrier gas. , 2002, Analytical chemistry.