The sleep apnea hypopnea syndrome (SAHS) is characterized by repetitive episodes of complete or partial upper airway obstruction leading to nocturnal sleep fragmentation and daytime hypersomnolence. Its incidence is estimated between 1% and 10% [1-3]. The morbidity and mortality (reported to be 12.5% and 35%, respectively, in untreated patients [4, 5]), can be diminished with effective treatment [4, 6-8], and thus early diagnosis is warranted. Definitive sleep studies necessitate hospitalization, overnight monitoring by a technician, and a 4- to-6 hour interpretation time. Several simplified methods that use ambulatory recordings to measure arterial oxyhemoglobin saturation (Sao 2), thoracoabdominal movements, heart rate, or breathing sounds or all three [9-11] can be used to evaluate patients suspected of having SAHS. Sleep-related breathing abnormalities are frequently accompanied by repetitive oxygen desaturations [12] that can be used to identify and characterize abnormal respiratory events during polysomnographic studies [13]. Home measurement of nighttime oxygen saturation levels using oximetry recording has been considered to be unreliable [14], because even 20 to 30 seconds of apnea can result in minimal Sao 2 changes [15] and because it does not effectively exclude substantial sleep apnea [16, 17]. These findings were based on the decrease in the Sao 2 level, and the number of times the Sao 2 level decreased below a fixed threshold; however, evidence exists that depth of the decreases in nocturnal Sao 2 levels do not always parallel the presence of sleep-induced breathing disorders [18]. The amount of apnea-related desaturation depends on several factors including the baseline Sao 2 level; the expiratory reserve volume; the total apnea time; and the different apnea types [19, 20]. Therefore, an apnea of a fixed duration will result in a wide range of decreases in Sao 2 levels from one patient to another and from one apnea event to the other, in the same patient. Further, the definition of apnea is based on the absence of airflow and not on the presence of desaturation. Therefore, considering only a fixed decrease in Sao 2 levels or a decrease below the Sao 2 threshold as suggestive criteria of respiratory abnormalities may lead to a misinterpretation of nocturnal oximetry test results. Thus, we reasoned that the interpretation of the Sao 2 recording based on the presence of repetitive fluctuations in the Sao 2 signal without rigid criteria for the amplitude of the Sao 2 decline should improve its accuracy as a test for detecting SAHS. Because a valid nocturnal home oximetry test would greatly decrease the costs of diagnosing these patients, we evaluated its utility for diagnosing SAHS using these criteria. Methods Patients A total of 240 consecutive outpatients referred to our sleep clinic (216 men, 24 women; ages 24 to 68 years; body mass index, 31.7 0.8 kg/m2 [mean SE]) were included in our study. They were clinically suspected of having SAHS because of loud snoring; nocturnal choking and awakenings or apneic events or all three reported by a bedmate; bad sleep quality; and daytime hypersomnolence. None had previously been investigated by home or sleep laboratory recordings. The review board on human studies in our institution approved the experimental protocol, and each patient gave his or her informed consent to participate in the study. Protocol Patients were prospectively evaluated by a single night nocturnal home oximetry test followed by a conventional polysomnographic study. Patients were asked to avoid alcohol consumption for at least 12 hours before the different studies. The ambulatory Sao 2 recording was done with a Biox IVA oximeter (Ohmeda, Louisville, Colorado) with a finger probe at a 0.5 Hz sampling frequency. The patients were instructed in the use of the oximeter by the sleep laboratory technician. They were told to install the finger probe, to check that the Sao 2 and pulse rate values appeared on the screen, and to begin the recording by pressing the key corresponding to the high-frequency sampling mode when they turned off the lights. They interrupted the recording if they awoke during the night and stopped it when they awoke in the morning. The home recording was done twice in 18 patients who did not sleep well during the first home recording. No treatment was initiated between home oximetry and the polysomnographic sleep study, and the patients weights remained unchanged. The sleep study was done within 1 month of the home Sao 2 monitoring (range, 1 to 4 weeks). Sleep studies included the determination of sleep stages (electroencephalogram, C4A1 and C3A1; electroculogram; submental electromyogram); nasal and mouth airflow with thermocouples (Grass Instruments, Quincy, Massachusetts); Sao 2 with a Criticare 504 ear oximeter (CSI, Waukesha, Wisconsin); electrocardiogram; and thoracoabdominal movements by respiratory inductive plethysmography (Respitrace, Ambulatory Monitoring, Ardsley, New York) calibrated by the isovolume method [21]. Intrathoracic pressures were recorded with an esophageal balloon in 105 patients. All measurements were recorded on a 16-channel polygraph (Model 78; Grass Instruments) running at 10 mm/s. Sleep stages were defined in 30-second periods according to standard criteria [22]. An apneic event was defined as a cessation of the oronasal flow for at least 10 seconds, and hypopnea was defined as a 50% decrease in the sum signal of the Respitrace associated with a desaturation greater than 4% [23]. An arousal was defined by the simultaneous transition to a lighter sleep stage with eye movements and an increase in electromyographic activity of less than 15 seconds [24]. Data Analysis and Statistical Analysis Polysomnographic recordings were manually interpreted by trained technicians who were unaware of the results of the oximetry (these recordings were interpreted before the sleep study). Home oximetry was classified as abnormal (suspicion of sleep-related breathing abnormalities) in the presence of repetitive episodes [mean for the whole night greater than 10/h] of transient desaturation followed by a rapid return to the baseline Sao 2 level using no minimum decrease in Sao 2 levels and no threshold. Figure 1 illustrates typical examples of abnormal oximetry recordings that were considered compatible with sleep-induced respiratory disorders. Abnormalities of the oximetry recording were of two types: deep repetitive desaturation episodes Figure 1, top) or low-amplitude periodic Sao 2 fluctuations Figure 1, bottom). The diagnosis of SAHS was confirmed when the apnea plus hypopnea index obtained by the sleep study was greater than 10. The individual baseline Sao 2 values obtained during home oximetry and polysomnographic study were compared by a Student paired t-test. The accuracy of home oximetry was evaluated by a contingency analysis with a two-tail Fisher exact test. Figure 1. Typical examples of abnormal, nocturnal arterial oxyhemoglobin saturation tracings. Top. Bottom. o o Results Almost all patients reported normal sleep quality and duration of sleep during the home oximetry recording. The diagnosis of SAHS was confirmed in 110 of the 240 patients studied. In this group, the apnea plus hypopnea index and the arousal index were 38.1 2.5/h and 36.8 2.7/h (mean SE), respectively. The mean total apnea time (percentage of total sleep time spent in apnea) was 13.1% (CI, 10.8% to 15.4%), and obstructive apnea represented 72.4% of total apnea time (CI, 66.7% to 78.1%). The baseline Sa (o)2 value was 95.2% 0.1% during home recording and was 95.7% 0.1% during the polysomnographic study (P > 0.05). Oximetry was abnormal in 176 patients, which included all but 2 of those with SAHS. In the SAHS group, 41 oximetry tests were interpreted as abnormal despite decreases in Sao 2 levels of less than 4% that did not reach 90% (see Figure 1, bottom). Nocturnal home oximetry was normal (absence of Sao 2 fluctuations, Figure 2 in all 62 patients who had no sleep disordered breathing. Figure 2. Typical example of a normal home oximetry recording. o The overall results of the home oximetry and polysomnographic testing are detailed in Figure 3. Based on a cutoff point of 10/h, home oximetry testing had a sensitivity of 108/110 or 98.2% (CI, 93.6% to 99.8%) and a specificity of 62/130 or 47.7% (CI, 38.8% to 56.6%). Given that 110 of 240 (46%) patients had sleep apnea, the likelihood of sleep apnea increased to 61.4% with a positive test and decreased to 3.1% with a negative test. The main characteristics of the patients with true and false results are reported in Table 1. The two patients who had a false-negative home oximetry recording (using a cutoff point of 10/h) had an apnea hypopnea index of 16.1/h and 14/h, respectively, and a body mass index of 27.1 kg/m2 and 32.5 kg/m2, respectively. Table 1. Characteristics of the Patients in the Different Groups* Figure 3. Contingency Tables Comparing the Results of the Home Oximetry and Polysomnographic Recordings Using Two Different Diagnosis Thresholds of the Apnea-Plus-Hypopnea Index (AHI). To specify the influence of the abnormal apnea-plus-hypopnea index threshold on these results, we analyzed our data using a different cutoff point of 20/h [4]. Using this cutoff point, 176 patients had an abnormal home oximetry test, and the diagnosis of SAHS was confirmed in 75 of them. Home oximetry test results were normal in the 64 patients without SAHS with no false-negative results (see Figure 3). Therefore, we used these SAHS diagnostic criteria, a sensitivity for nocturnal home oximetry testing of 100%; a specificity of 38.8%; a positive predictive value of 42.6%; and a negative predictive value of 100% Figure 3 [P < 104]. The reproducibility of our interpretation criteria was verified in 60 randomly selected home oximetry recordings interpreted blindly by two physicians. The concordance between the two interpretations was 95%. Discus
[1]
M. Sackner,et al.
Validation of respiratory inductive plethysmography using different calibration procedures.
,
2015,
The American review of respiratory disease.
[2]
C. Guilleminault,et al.
Does oximetry contribute to the detection of apneic events? Mathematical processing of the SaO2 signal.
,
1991,
Chest.
[3]
Indications and standards for cardiopulmonary sleep studies. American Thoracic Society. Medical Section of the American Lung Association.
,
1989,
The American review of respiratory disease.
[4]
A. Williams,et al.
Screening for sleep apnea using pulse oximetry and a clinical score.
,
1991,
Chest.
[5]
M. Kryger,et al.
Identification and quantification of apneas by computer-based analysis of oxygen saturation.
,
1988,
The American review of respiratory disease.
[6]
C. Sullivan,et al.
Remission of severe obesity-hypoventilation syndrome after short-term treatment during sleep with nasal continuous positive airway pressure.
,
2015,
The American review of respiratory disease.
[7]
F. Sériès,et al.
Role of lung volumes in sleep apnoea-related oxygen desaturation.
,
1989,
The European respiratory journal.
[8]
T. Roth,et al.
Night-to-night consistency of apneas during sleep.
,
1984,
The American review of respiratory disease.
[9]
AJ McMichael,et al.
Have increases in solar ultraviolet exposure contributed to the rise in incidence of non-Hodgkin's lymphoma?
,
1996,
British Journal of Cancer.
[10]
P. Lavie,et al.
Incidence of sleep apnea in a presumably healthy working population: a significant relationship with excessive daytime sleepiness.
,
1983,
Sleep.
[11]
N J Douglas,et al.
The sleep hypopnea syndrome.
,
1988,
The American review of respiratory disease.
[12]
N. Saunders,et al.
Evaluation of a microprocessor-based portable home monitoring system to measure breathing during sleep.
,
1987,
Sleep.
[13]
C Guilleminault,et al.
Snoring (I). Daytime sleepiness in regular heavy snorers.
,
1991,
Chest.
[14]
L. Findley,et al.
Hypoxemia during apnea in normal subjects: mechanisms and impact of lung volume.
,
1983,
Journal of applied physiology: respiratory, environmental and exercise physiology.
[15]
H. Moldofsky,et al.
Physiological determinants of nocturnal arterial oxygenation in patients with obstructive sleep apnea.
,
1985,
Journal of applied physiology.
[16]
T Penzel,et al.
MESAM: a heart rate and snoring recorder for detection of obstructive sleep apnea.
,
1990,
Sleep.
[17]
M Partinen,et al.
Daytime sleepiness and vascular morbidity at seven-year follow-up in obstructive sleep apnea patients.
,
1990,
Chest.
[18]
E. Svanborg,et al.
A limited diagnostic investigation for obstructive sleep apnea syndrome. Oximetry and static charge sensitive bed.
,
1990,
Chest.
[19]
D. Rapoport,et al.
Reversal of the "Pickwickian syndrome" by long-term use of nocturnal nasal-airway pressure.
,
1982,
The New England journal of medicine.
[20]
J. Chambron,et al.
Left ventricular ejection fraction in obstructive sleep apnea. Effects of long-term treatment with nasal continuous positive airway pressure.
,
1991,
Chest.
[21]
M. Kryger,et al.
Mortality and apnea index in obstructive sleep apnea. Experience in 385 male patients.
,
1988,
Chest.
[22]
A. J. Block,et al.
Sleep Apnea, Hypopnea and Oxygen Desaturation in Normal Subjects: A Strong Male Predominance
,
1980
.
[23]
J. Walker,et al.
Ear oximetry to detect apnea and differentiate rapid eye movement (REM) and non-REM (NREM) sleep. Screening for the sleep apnea syndrome.
,
1986,
Chest.
[24]
M J Hensley,et al.
A comparison of clinical assessment and home oximetry in the diagnosis of obstructive sleep apnea.
,
1993,
The American review of respiratory disease.
[25]
F. Sériès,et al.
Influence of apnea type and sleep stage on nocturnal postapneic desaturation.
,
1990,
The American review of respiratory disease.
[26]
T. Penzel,et al.
Studies in the prevalence of sleep apnea activity (SAA): evaluation of ambulatory screening results.
,
1986,
European journal of respiratory diseases. Supplement.