Wind effects on a long-span beam string roof structure: Wind tunnel test, field measurement and numerical analysis

Abstract The Guangzhou International Convention & Exhibition Center (GICEC) with roof dimensions of 210 m wide and 457 m long is the largest exhibition center in Asia and the 2nd largest of this kind in the world. This paper presents results from a combined study of wind tunnel test, full-scale measurement, and numerical analysis of wind effects on the long-span beam string roof structure. In the wind tunnel test, wind-induced pressures including mean and fluctuating components were measured from the roof of a 1:300 scale GICEC model under suburban boundary layer wind flow configuration. The Proper Orthogonal Decomposition (POD) method and the quasi-steady approach as well as probability analysis were adopted to estimate the characteristics of the fluctuating wind pressures on the roof. On the other hand, full-scale measurements of wind actions and wind-induced structural responses of the roof were conducted during the passage of Typhoon Nuri. The field data such as wind speed, wind direction, and acceleration responses, etc., were continuously and simultaneously monitored from a wind and structural response monitoring system installed on the roof structure during the typhoon. Detailed analysis of the field data was performed to investigate the characteristics of the typhoon-generated wind and the wind-induced vibration of the long-span roof structure under typhoon condition. The dynamic characteristics of the roof were determined from the field measurements and comparisons with those calculated from the finite element model (FEM) of the structure were made. The damping ratios of the roof structure were estimated by means of the random decrement method and the amplitude-dependent damping characteristics were presented and discussed. Finally, the full-scale measurements were compared with the model test results to examine the accuracy of the wind tunnel test results and to identify possible modelling errors in the numerical study. The results presented in this paper are expected to be of considerable interest and of use to researchers and professionals involved in designing long-span roof structures.

[1]  Chris Letchford,et al.  Mean wind loading at the leading ends of free standing walls , 1999 .

[2]  Kit Ming Lam,et al.  Occurrence of peak lifting actions on a large horizontal cantilevered roof , 2002 .

[3]  Takeshi Hongo,et al.  Wind-induced dynamic behavior and its load estimation of a single-layer latticed dome with a long span , 2001 .

[4]  Qiusheng Li,et al.  Full-scale measurements and numerical evaluation of wind-induced vibration of a 63-story reinforced concrete tall building , 2004 .

[5]  Theodore Stathopoulos,et al.  Full-scale measurements of wind pressures on flat roof corners , 1990 .

[6]  H. Kawai,et al.  Characteristics of fluctuating suction and conical vortices on a flat roof in oblique flow , 1996 .

[7]  N. Isyumov,et al.  Wind pressures acting on low-rise buildings , 1999 .

[8]  Chris Letchford,et al.  Pressure factors for edge regions on low rise building roofs , 1995 .

[9]  Chris Letchford,et al.  Dynamic characteristics of cantilever grandstand roofs , 2002 .

[10]  J. Y. Fu,et al.  Typhoon effects on super-tall buildings , 2008 .

[11]  K. Kondo,et al.  Fluctuating wind pressure measured with tubing system , 1992 .

[12]  N. Isyumov,et al.  Peak gust pressures acting on the roof and wall edges of a low-rise building , 1998 .

[13]  Mircea Grigoriu,et al.  Non-Gaussian Wind Pressure on Prismatic Buildings. I: Stochastic Field , 2001 .

[14]  Qiusheng Li,et al.  Probabilistic characteristics of pressure fluctuations in separated and reattaching flows for various free-stream turbulence , 1999 .

[15]  G P Tilly,et al.  DAMPING MEASUREMENTS ON STEEL AND COMPOSITE BRIDGES , 1977 .

[16]  A. P. Jeary,et al.  Random damping in buildings and its AR model , 1999 .

[17]  Yukio Tamura,et al.  Proper orthogonal decomposition and reconstruction of multi-channel roof pressure , 1995 .

[18]  A. P. Jeary,et al.  The description and measurement of nonlinear damping in structures , 1996 .

[19]  Yukio Tamura,et al.  Study of wind-induced response of long-span structure , 1999 .

[20]  J. Holmes Non-gaussian characteristics of wind pressure fluctuations , 1981 .

[21]  J. Ribeiro,et al.  Probability distribution of forces and pressures on a square cylinder , 1992 .

[22]  Kenny C. S Kwok,et al.  Eigenvector modes of fluctuating pressures on low-rise building models , 1997 .

[23]  Y. Tamura,et al.  PROPER ORTHOGONAL DECOMPOSITION OF RANDOM WIND PRESSURE FIELD , 1999 .

[24]  R. P. Hoxey,et al.  Wind loads on boundary walls: Full-scale studies , 1997 .

[25]  Y. Tamura,et al.  Evaluation of amplitude-dependent damping and natural frequency of buildings during strong winds , 1996 .

[26]  A. P. Jeary,et al.  Damping in tall buildings—a mechanism and a predictor , 1986 .

[27]  Peter Richards,et al.  Full-scale wind load measurements point the way forward , 1995 .

[28]  N. J. Cook,et al.  Calibration of the quasi-static and peak-factor approaches to the assessment of wind loads against the method of Cook and Mayne , 1982 .

[29]  A. P. Jeary,et al.  Field measurements of wind effects on the tallest building in Hong Kong , 2003 .

[30]  Dikai Liu,et al.  Using neural networks to model and predict amplitude dependent damping in buildings , 1999 .

[31]  Dikai Liu,et al.  Damping in buildings : its neural network model and AR model , 2000 .

[32]  Chris Letchford,et al.  Net pressures on a low-rise full scale building , 1999 .

[33]  Yukio Tamura,et al.  Proper orthogonal decomposition study of approach wind-building pressure correlation , 1997 .

[34]  Dikai Liu,et al.  Damping of tall buildings: its evaluation and probabilistic characteristics , 1999 .

[35]  Claudio Borri,et al.  Wind response of large roofs of stadions and arena , 2007 .