A miniature microsurgical instrument tip force sensor for enhanced force feedback during robot-assisted manipulation

This paper reports the development of a new miniature force sensor designed to measure contact forces at the tip of a microsurgical instrument in three dimensions, and its application to scaled force feedback using a cooperatively manipulated microsurgical assistant robot. The principal features of the sensor are its small size of 12.5 mm in diameter and 15 mm in height, a novel configuration of flexure beams and strain gauges in order to measure forces isotropically at the instrument tip 40 mm from the sensor body, and sub-mN three-axis force-sensing resolution.

[1]  Peter Kazanzides,et al.  An image-directed robotic system for precise orthopaedic surgery , 1994, IEEE Trans. Robotics Autom..

[2]  Louis L. Whitcomb,et al.  Adaptive force control of position/velocity controlled robots: theory and experiment , 2001, Proceedings 2001 IEEE/RSJ International Conference on Intelligent Robots and Systems. Expanding the Societal Role of Robotics in the the Next Millennium (Cat. No.01CH37180).

[3]  Michael A. Peshkin,et al.  The use of localizers, robots and synergistic devices in CAS , 1997, CVRMed.

[4]  D. Taghirad Ieee Transactions on Robotics and Automation 1 Robust Torque Control of Harmonic Drive Systems , 1997 .

[5]  Russell H. Taylor,et al.  A telerobotic assistant for laparoscopic surgery , 1995 .

[6]  Russell H. Taylor,et al.  A Modular Surgical Robotic System for Image Guided Percutaneous Procedures , 1998, MICCAI.

[7]  Russell H. Taylor,et al.  A Miniature Instrument Tip Force Sensor for Robot/Human Cooperative Microsurgical Manipulation with Enhanced Force Feedback , 2000, MICCAI.

[8]  Brian L. Davies,et al.  Experiences with robotic systems for knee surgery , 1997, CVRMed.

[9]  Ève Coste-Manière,et al.  Planning and Simulation of Robotically Assisted Minimal Invasive Surgery , 2000, MICCAI.

[10]  W. Boyd,et al.  3-D image guidance for minimally invasive robotic coronary artery bypass. , 2000, The heart surgery forum.

[11]  C.N. Riviere,et al.  Intraoperative instrument motion sensing for microsurgery , 1999, Proceedings of the First Joint BMES/EMBS Conference. 1999 IEEE Engineering in Medicine and Biology 21st Annual Conference and the 1999 Annual Fall Meeting of the Biomedical Engineering Society (Cat. N.

[12]  Dominiek Reynaerts,et al.  A mechatronic approach to microsystem design , 1996 .

[13]  C. Riviere,et al.  Characteristics of hand motion of eye surgeons , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[14]  Russell H. Taylor,et al.  Preliminary experiments in cooperative human/robot force control for robot assisted microsurgical manipulation , 2000, Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065).

[15]  Patrick S. Jensen,et al.  Surgical Forces and Tactile Perception During Retinal Microsurgery , 1999, MICCAI.

[16]  Russell H. Taylor,et al.  A Steady-Hand Robotic System for Microsurgical Augmentation , 1999, Int. J. Robotics Res..

[17]  R. D. Hibberd,et al.  Robot assisted knee surgery , 1995 .