Is SPE necessary for environmental analysis? A quantitative comparison of matrix effects from large-volume injection and solid-phase extraction based methods.

Environmental analysis by large-volume injection (LVI) was compared to solid-phase extraction (SPE) based methods using matrix effects as a quantitative indicator of analytical signal quality. LVI was performed by the direct injection of 900 μL of wastewater onto a high-performance liquid chromatography (HPLC) column while SPE-based methods utilized octadecyl silane (C18) and hydrophobic-lypophilic balance (HLB) solid phases to preconcentrate wastewater prior to analysis. Model analytes from three classes of environmental contaminants were selected for study including four estrogens (estrone, estradiol, estriol, and ethinylestradiol), eight perfluoroalkyl carboxylates (C4-C11), and five perfluoroalkyl sulfonates (C4, C6-C8, and C10). The matrix effects on analytes were assessed by two approaches (quantitatively by calculating percent matrix effects and qualitatively with postcolumn infusions) and compared across LVI- and SPE-based methods at constant (high and low) analyte-to-matrix mass ratios. The results from this study demonstrated that the LVI-based method produced analytical signals of quality similar to the two SPE-based methods. Furthermore, LVI presented a clear advantage over SPE because it was performed at lower cost, required fewer materials, involved less labor and eliminated the analyte loss associated with SPE.

[1]  K. Ensing,et al.  On-line coupling of solid-phase extraction with mass spectrometry for the analysis of biological samples. I. Determination of clenbuterol in urine. , 1999, Journal of chromatography. A.

[2]  P. Kebarle,et al.  Electrospray: from ions in solution to ions in the gas phase, what we know now. , 2009, Mass spectrometry reviews.

[3]  J. V. Sancho,et al.  Study of matrix effects on the direct trace analysis of acidic pesticides in water using various liquid chromatographic modes coupled to tandem mass spectrometric detection. , 2001, Journal of chromatography. A.

[4]  J. Llorca-Pórcel,et al.  Ultra trace determination of 31 pesticides in water samples by direct injection-rapid resolution liquid chromatography-electrospray tandem mass spectrometry. , 2008, Analytica Chimica Acta.

[5]  T. Olah,et al.  The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compounds. , 1999, Rapid communications in mass spectrometry : RCM.

[6]  M. Karas,et al.  Effect of different solution flow rates on analyte ion signals in nano-ESI MS, or: when does ESI turn into nano-ESI? , 2003, Journal of the American Society for Mass Spectrometry.

[7]  Jennifer A Field,et al.  Quantitative determination of fluorinated alkyl substances by large-volume-injection liquid chromatography tandem mass spectrometry-characterization of municipal wastewaters. , 2006, Environmental science & technology.

[8]  L. Barber,et al.  Reproductive disruption in fish downstream from an estrogenic wastewater effluent. , 2008, Environmental science & technology.

[9]  Nobuyoshi Yamashita,et al.  Analysis of trifluoroacetic acid and other short-chain perfluorinated acids (C2-C4) in precipitation by liquid chromatography-tandem mass spectrometry: comparison to patterns of long-chain perfluorinated acids (C5-C18). , 2008, Analytica chimica acta.

[10]  G. Saccani,et al.  Determination of acrylamide in drinking water by large-volume direct injection and ion-exclusion chromatography-mass spectrometry. , 2004, Journal of chromatography. A.

[11]  C. Criddle,et al.  Quantitative determination of perfluorochemicals in sediments and domestic sludge. , 2005, Environmental science & technology.

[12]  M. Grenier-loustalot,et al.  Analytical methods for the determination of selected steroid sex hormones and corticosteriods in wastewater , 2007, Analytical and bioanalytical chemistry.

[13]  C. Enke,et al.  A predictive model for matrix and analyte effects in electrospray ionization of singly-charged ionic analytes. , 1997, Analytical chemistry.

[14]  W. Schulz,et al.  Novel applications of highly sensitive liquid chromatography/mass spectrometry/mass spectrometry for the direct detection of ultra-trace levels of contaminants in water. , 2006, Rapid communications in mass spectrometry : RCM.

[15]  Mario Thevis,et al.  Anabolic, doping, and lifestyle drugs, and selected metabolites in wastewater—detection, quantification, and behaviour monitored by high-resolution MS and MSn before and after sewage treatment , 2010, Analytical and bioanalytical chemistry.

[16]  W. Lambert,et al.  Tackling matrix effects during development of a liquid chromatographic-electrospray ionisation tandem mass spectrometric analysis of nine basic pharmaceuticals in aqueous environmental samples. , 2006, Journal of chromatography. A.

[17]  T. Ternes,et al.  Determination of neutral pharmaceuticals in wastewater and rivers by liquid chromatography-electrospray tandem mass spectrometry. , 2001, Journal of chromatography. A.

[18]  R. Vreeken,et al.  Determination of polar organophosphorus pesticides in aqueous samples by direct injection using liquid chromatography-tandem mass spectrometry. , 2001, Journal of chromatography. A.

[19]  P. de Voogt,et al.  Trace analysis of isothiazolinones in water samples by large-volume direct injection liquid chromatography tandem mass spectrometry. , 2010, Journal of Chromatography A.

[20]  Jeong-Eun Oh,et al.  Evaluation of the fate of perfluoroalkyl compounds in wastewater treatment plants. , 2010, Water research.

[21]  Nicola C Hughes,et al.  Determination of carryover and contamination for mass spectrometry-based chromatographic assays , 2007, The AAPS Journal.

[22]  S. Mabury,et al.  Determination of perfluorinated surfactants in surface water samples by two independent analytical techniques: liquid chromatography/tandem mass spectrometry and 19F NMR. , 2001, Analytical chemistry.

[23]  K. Shih,et al.  Perfluorochemicals in wastewater treatment plants and sediments in Hong Kong. , 2010, Environmental pollution.

[24]  C. Poole,et al.  Mechanistic study of the sorption properties of OASIS® HLB and its use in solid-phase extraction , 2002 .

[25]  D. Hercules,et al.  Effect of liquid chromatography separation of complex matrices on liquid chromatography-tandem mass spectrometry signal suppression. , 2001, Journal of chromatography. A.

[26]  F. Gosetti,et al.  Signal suppression/enhancement in high-performance liquid chromatography tandem mass spectrometry. , 2010, Journal of chromatography. A.

[27]  John Flaherty,et al.  Method for trace level analysis of C8, C9, C10, C11, and C13 perfluorocarbon carboxylic acids in water. , 2005, Analytical chemistry.

[28]  T. Reemtsma,et al.  Compensation of matrix effects by postcolumn infusion of a monitor substance in multiresidue analysis with LC-MS/MS. , 2009, Analytical chemistry.

[29]  S. Sauvé,et al.  Analysis of natural and synthetic estrogenic endocrine disruptors in environmental waters using online preconcentration coupled with LC-APPI-MS/MS. , 2008, Talanta.

[30]  Z. Sosa-Ferrera,et al.  Determination of alkylphenol polyethoxylates, bisphenol-A, 17α-ethynylestradiol and 17β-estradiol and its metabolites in sewage samples by SPE and LC/MS/MS. , 2010, Journal of hazardous materials.

[31]  P. Taylor Matrix effects: the Achilles heel of quantitative high-performance liquid chromatography-electrospray-tandem mass spectrometry. , 2005, Clinical biochemistry.

[32]  Thorsten Reemtsma,et al.  Operational options to reduce matrix effects in liquid chromatography-electrospray ionization-mass spectrometry analysis of aqueous environmental samples. , 2005, Journal of chromatography. A.

[33]  M. Schlüsener,et al.  Determination of steroid hormones, hormone conjugates and macrolide antibiotics in influents and effluents of sewage treatment plants utilising high-performance liquid chromatography/tandem mass spectrometry with electrospray and atmospheric pressure chemical ionisation. , 2005, Rapid communications in mass spectrometry : RCM.

[34]  C. Poole,et al.  Contributions of theory to method development in solid-phase extraction. , 2000, Journal of chromatography. A.

[35]  W. Lambert,et al.  Matrix effect in bio-analysis of illicit drugs with LC-MS/MS: Influence of ionization type, sample preparation, and biofluid , 2003, Journal of the American Society for Mass Spectrometry.

[36]  A. L. Roberts,et al.  Quantification of drugs of abuse in municipal wastewater via SPE and direct injection liquid chromatography mass spectrometry , 2010, Analytical and bioanalytical chemistry.

[37]  L. Wiest,et al.  Multi-residue analysis of steroids at sub-ng/L levels in surface and ground-waters using liquid chromatography coupled to tandem mass spectrometry. , 2008, Journal of chromatography. A.

[38]  Walter A. Korfmacher,et al.  Investigation of matrix effects in bioanalytical high-performance liquid chromatography/tandem mass spectrometric assays: application to drug discovery. , 2003, Rapid communications in mass spectrometry : RCM.

[39]  P. Kebarle A brief overview of the present status of the mechanisms involved in electrospray mass spectrometry. , 2000, Journal of mass spectrometry : JMS.

[40]  J. S. Eldridge,et al.  Quantitative characterization of trace levels of PFOS and PFOA in the Tennessee River. , 2002, Environmental science & technology.

[41]  Will J. Backe,et al.  Analysis of androgenic steroids in environmental waters by large-volume injection liquid chromatography tandem mass spectrometry. , 2011, Analytical chemistry.

[42]  Virginie Gabet,et al.  Analysis of estrogens in environmental matrices , 2007 .

[43]  R. Majors Current trends in HPLC column usage , 1994 .

[44]  Serge Rudaz,et al.  Matrix effect in LC-ESI-MS and LC-APCI-MS with off-line and on-line extraction procedures. , 2004, Journal of chromatography. A.

[45]  B. Matuszewski,et al.  Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS. , 2003, Analytical chemistry.

[46]  J. V. Sancho,et al.  Study of different atmospheric-pressure interfaces for LC-MS/MS determination of acrylamide in water at sub-ppb levels. , 2006, Journal of mass spectrometry : JMS.

[47]  C. Banta-Green,et al.  Eliminating solid phase extraction with large-volume injection LC/MS/MS: analysis of illicit and legal drugs and human urine indicators in U.S. wastewaters. , 2008, Environmental science & technology.

[48]  D. Armstrong,et al.  Mechanism of signal suppression by anionic surfactants in capillary electrophoresis-electrospray ionization mass spectrometry. , 1996, Analytical chemistry.

[49]  Kurunthachalam Kannan,et al.  Mass loading and fate of perfluoroalkyl surfactants in wastewater treatment plants. , 2006, Environmental science & technology.

[50]  R. Buck,et al.  Matrix effect-free analytical methods for determination of perfluorinated carboxylic acids in environmental matrixes. , 2005, Analytical chemistry.

[51]  C. Metcalfe,et al.  Characterizing and compensating for matrix effects using atmospheric pressure chemical ionization liquid chromatography-tandem mass spectrometry: analysis of neutral pharmaceuticals in municipal wastewater. , 2008, Analytical chemistry.

[52]  Willy Lambert,et al.  Countering matrix effects in environmental liquid chromatography-electrospray ionization tandem mass spectrometry water analysis for endocrine disrupting chemicals. , 2004, Journal of chromatography. A.

[53]  Silke Gerstmann,et al.  Perfluorooctane surfactants in waste waters, the major source of river pollution. , 2008, Chemosphere.

[54]  Tsuyoshi Okazawa,et al.  Analysis of perfluorinated acids at parts-per-quadrillion levels in seawater using liquid chromatography-tandem mass spectrometry. , 2004, Environmental science & technology.

[55]  Christoph Ort,et al.  Sampling for PPCPs in wastewater systems: comparison of different sampling modes and optimization strategies. , 2010, Environmental science & technology.

[56]  C. Enke,et al.  Importance of gas-phase proton affinities in determining the electrospray ionization response for analytes and solvents. , 2000, Journal of mass spectrometry : JMS.

[57]  Tsuyoshi Okazawa,et al.  Analysis of fluorotelomer alcohols, fluorotelomer acids, and short- and long-chain perfluorinated acids in water and biota. , 2005, Journal of chromatography. A.

[58]  Wolfgang Ruck,et al.  Liquid chromatography-tandem mass spectrometry analysis of estrogenic compounds in coastal surface water of the Baltic Sea. , 2005, Journal of chromatography. A.

[59]  M. Schlüsener,et al.  Behavior of Steroid Hormones and Conjugates During Wastewater Treatment – A Comparison of Three Sewage Treatment Plants , 2008 .

[60]  Christoph Ort,et al.  Occurrence and mass flows of fluorochemicals in the Glatt Valley watershed, Switzerland. , 2008, Environmental science & technology.

[61]  Thomas Heberer,et al.  Determination of estrogenic steroids in surface water and wastewater by liquid chromatography-electrospray tandem mass spectrometry. , 2005, Journal of separation science.

[62]  Tyge Greibrokk,et al.  Determination of perfluorooctane sulfonate and perfluorooctanoic acid in human plasma by large volume injection capillary column switching liquid chromatography coupled to electrospray ionization mass spectrometry. , 2004, Journal of separation science.

[63]  C. Iden,et al.  Determination of steroid estrogens in wastewater by immunoaffinity extraction coupled with HPLC-electrospray-MS. , 2001, Analytical chemistry.

[64]  Jennifer A Field,et al.  Trace analysis of environmental matrices by large-volume injection and liquid chromatography–mass spectrometry , 2011, Analytical and Bioanalytical Chemistry.

[65]  Timothy Olah,et al.  Mechanistic investigation of ionization suppression in electrospray ionization , 2000, Journal of the American Society for Mass Spectrometry.