Standardization of 68Ge/68Ga Using Three Liquid Scintillation Counting Based Methods

A solution containing 68Ge in equilibrium with its daughter, 68Ga, has been standardized for the first time at the National Institute of Standards and Technology (NIST) using 3 liquid scintillation-based techniques: live-timed 4πβ -γ anticoincidence (LTAC) counting, the Triple-to-Double Coincidence Ratio (TDCR) method, and 3H-standard efficiency tracing with the CIEMAT1/NIST (CNET) method. The LTAC technique is much less dependent on level scheme data and model-dependent parameters and was thus able to provide a reference activity concentration value for the master solution with a combined standard uncertainty of about 0.3 %. The other two methods gave activity concentration values with respective differences from the reference value of +1.2 % and −1.5 %, which were still within the experimental uncertainties. Measurements made on the NIST “4π”γ secondary standard ionization chamber allowed for the determination of calibration factors for that instrument, allowing future calibrations to be made for 68Ge/68Ga without the need for a primary measurement. The ability to produce standardized solutions of 68Ge presents opportunities for the development of a number of NIST-traceable calibration sources with very low (<1 %) relative standard uncertainties that can be used in diagnostic medical imaging.

[1]  G. Kubicek,et al.  Radioassays and experimental evaluation of dose calibrator settings for 18F. , 2001, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[2]  W. B. Mann,et al.  Standardization of carbon-14 by 4πβ liquid scintillation efficiency tracing with hydrogen-3 , 1986 .

[3]  E. Iso,et al.  Measurement Uncertainty and Probability: Guide to the Expression of Uncertainty in Measurement , 1995 .

[4]  R. Collé,et al.  Construction and implementation of the NIST triple-to-double coincidence ratio (TDCR) spectrometer. , 2004, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[5]  R. Collé,et al.  Standardization of 63Ni by 4πβ Liquid Scintillation Spectrometry With 3H-Standard Efficiency Tracing , 1997, Journal of research of the National Institute of Standards and Technology.

[6]  P Cassette,et al.  Measurement of a 103Pd solution using the TDCR method by LSC. , 2004, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[7]  R. Broda A review of the triple-to-double coincidence ratio (TDCR) method for standardizing radionuclides. , 2003, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[8]  R. Broda,et al.  The enhanced triple to double coincidence ratio (ETDCR) method for standardization of radionuclides by liquid scintillation counting , 1992 .

[9]  Christian Negut,et al.  Standardization of 68(Ge+Ga). , 2004, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[10]  B. Zimmerman,et al.  Monte Carlo calculations of spectra and interaction probabilities for photons in liquid scintillators for use in the standardization of radionuclides. , 2006, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[11]  Carl Eklund,et al.  National Institute for Standards and Technology , 2009, Encyclopedia of Biometrics.

[12]  J. M. Calhoun Radioactivity calibrations with the "4π" Gamma ionization chamber and other radioactivity calibration capabilities , 1987 .

[13]  H. Schrader,et al.  Standardization and decay data of 68Ge/68Ga , 1994 .

[14]  J. Fowler,et al.  Journal of Research of the National Institute of Standards and Technology INFORMATION TECHNOLOGY FOR ENGINEERING AND MANUFACTURING Gaithersburg , MD June 12-13 , 2000 , 2000 .

[15]  R. Broda,et al.  Standardization of pure beta emitters by liquid-scintillation counting , 1988 .

[16]  M. Schultz,et al.  Liquid-scintillation-based anticoincidence counting of Co-60 and Pb-210. , 2008, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[17]  P. Cassette,et al.  63Ni, its half-life and standardization: revisited. , 2008, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[18]  J. Baró,et al.  An algorithm for Monte Carlo simulation of coupled electron-photon transport , 1997 .

[19]  Barry N. Taylor,et al.  Guidelines for Evaluating and Expressing the Uncertainty of Nist Measurement Results , 2017 .

[20]  D. D. Hoppes,et al.  Standardization of 18F for use in positron-emission tomography , 1983 .