Toward continuous glucose monitoring with planar modified biosensors and microdialysis. Study of temperature, oxygen dependence and in vivo experiment.

Glucose biosensors based on the use of planar screen-printed electrodes modified with an electrochemical mediator and with glucose oxidase have been optimised for their application in the continuous glucose monitoring in diabetic patients. A full study of their operative stability and temperature dependence has been accomplished, thus giving useful information for in vivo applications. The effect of dissolved oxygen concentration in the working solution was also studied in order to evaluate its effect on the linearity of the sensors. Glucose monitoring performed with serum samples was performed to evaluate the effect of matrix components on operative stability and demonstrated an efficient behaviour for 72 h of continuous monitoring. Finally, these studies led to a sensor capable of detecting glucose at concentrations as low as 0.04 mM and with a good linearity up to 2.0 mM (at 37 degrees C) with an operative stability of ca. 72 h, thus demonstrating the possible application of these sensors for continuous glucose monitoring in conjunction with a microdialysis probe. Moreover, preliminary in vivo experiments for ca. 20 h have demonstrated the feasibility of this system.

[1]  A Caduff,et al.  First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system. , 2003, Biosensors & bioelectronics.

[2]  F Valgimigli,et al.  A microdialysis technique for continuous subcutaneous glucose monitoring in diabetic patients (part 1). , 2003, Biosensors & bioelectronics.

[3]  Alberto Maran,et al.  Continuous subcutaneous glucose monitoring in diabetic patients: a multicenter analysis. , 2002, Diabetes care.

[4]  H. Shamoon Continuous glucose monitoring: the next step toward closing the loop. , 2000, Diabetes technology & therapeutics.

[5]  GR Ambler,et al.  Does continuous glucose monitoring have clinical utility in contemporary management of diabetes? , 2004, Journal of paediatrics and child health.

[6]  D. Moscone,et al.  Subcutaneous microdialysis probe coupled with glucose biosensor for in vivo continuous monitoring. , 1992, Talanta.

[7]  G Reach,et al.  A user-friendly method for calibrating a subcutaneous glucose sensor-based hypoglycaemic alarm. , 1997, Biosensors & bioelectronics.

[8]  O. Khalil,et al.  Non-invasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium. , 2004, Diabetes technology & therapeutics.

[9]  J-H Park,et al.  The correlation of the complex dielectric constant and blood glucose at low frequency. , 2003, Biosensors & bioelectronics.

[10]  S. Piletsky,et al.  In vitro diagnostics in diabetes: meeting the challenge. , 1999, Clinical chemistry.

[11]  L. Jovanovic,et al.  Noninvasive glucose monitoring: comprehensive clinical results. Cygnus Research Team. , 1999, JAMA.

[12]  F Valgimigli,et al.  A microdialysis technique for continuous subcutaneous glucose monitoring in diabetic patients (part 2). , 2003, Biosensors & bioelectronics.

[13]  F. Ricci,et al.  Prussian Blue based screen printed biosensors with improved characteristics of long-term lifetime and pH stability. , 2003, Biosensors & bioelectronics.

[14]  N F de Rooij,et al.  In-vivo behaviour of hypodermically implanted microfabricated glucose sensors. , 1991, Biosensors & bioelectronics.

[15]  J. Pickup,et al.  Developing glucose sensors for in vivo use. , 1993, Trends in biotechnology.

[16]  R O Potts,et al.  Clinical evaluation of the GlucoWatch biographer: a continual, non-invasive glucose monitor for patients with diabetes. , 2001, Biosensors & bioelectronics.

[17]  W Kerner,et al.  Implantable glucose sensors: present status and future developments. , 2001, Experimental and clinical endocrinology & diabetes : official journal, German Society of Endocrinology [and] German Diabetes Association.

[18]  Jayalakshmi,et al.  Design of a Biosensor for Continual, Transdermal Glucose Monitoring. , 1999, Clinical chemistry.

[19]  F. Sternberg,et al.  On line continuous monitoring of subcutaneous tissue glucose in men by combining portable glucosensor with microdialysis , 1992, Diabetologia.

[20]  J C Pickup,et al.  Clinicians' requirements for chemical sensors for in vivo monitoring: a multinational survey. , 1991, Biosensors & bioelectronics.

[21]  F Valgimigli,et al.  Novel planar glucose biosensors for continuous monitoring use. , 2005, Biosensors & bioelectronics.