A comparison of 4D cone-beam CT algorithms for slowly rotating scanners

The study compares several algorithms for the 4D reconstruction of cone-beam computed tomography (CBCT) data that were recently proposed and which can be used from slowly rotating devices. In our case the imaging units are mounted to linear particle accelerators (LINAC). The algorithms are the conventional phase-correlated reconstruction (PC), the McKinnon/Bates-Algorithm, the prior image constrained compressed sensing (PICCS) algorithm, the total-variation minimization (TV) algorithm, and our auto-adaptive phase-correlation (AAPC) algorithm. For each algorithm the same motion-affected rawdata are used and the reconstruction results compared to each other regarding their noise and artifact levels, as well as temporal resolution, and computational complexity and convergence. These criteria result in a discussion of the advantages and disadvantages of each algorithm. The temporal resolution is best in the algorithms which exclusively use data from a single motion phase only. The iterative algorithms show lower noise and artifact levels but are computationally complex and therefore may have a limited usage in the clinical application. Algorithms which include image enhancements beside a faster reconstruction represent a suitable trade-off for the clinical workflow.

[1]  M. V. van Herk,et al.  Respiratory correlated cone beam CT. , 2005, Medical physics.

[2]  Jiayu Song,et al.  Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT. , 2007, Medical physics.

[3]  S. Leng,et al.  High temporal resolution and streak-free four-dimensional cone-beam computed tomography , 2008, Physics in medicine and biology.

[4]  Jie Tang,et al.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. , 2008, Medical physics.

[5]  A. Kak,et al.  Simultaneous Algebraic Reconstruction Technique (SART): A Superior Implementation of the Art Algorithm , 1984, Ultrasonic imaging.

[6]  Guang-Hong Chen,et al.  Temporal resolution improvement using PICCS in MDCT cardiac imaging. , 2009, Medical physics.

[7]  T. Pan,et al.  Voxel-based reconstruction combined with motion detection for slow rotating 4D CBCT , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[8]  Willi A Kalender,et al.  Extended parallel backprojection for standard three-dimensional and phase-correlated four-dimensional axial and spiral cone-beam CT with arbitrary pitch, arbitrary cone-angle, and 100% dose usage. , 2004, Medical physics.

[9]  Richard A. Robb,et al.  3-D Reconstruction of the Heart from Few Projections: A Practical Implementation of the McKinnon-Bates Algorithm , 1986, IEEE Transactions on Medical Imaging.

[10]  Guang-Hong Chen,et al.  Streaking artifacts reduction in four-dimensional cone-beam computed tomography. , 2008, Medical physics.

[11]  L. Xing,et al.  Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy. , 2007, International journal of radiation oncology, biology, physics.

[12]  P. Munro,et al.  Four-dimensional cone-beam computed tomography using an on-board imager. , 2006, Medical physics.

[13]  F. A. Seiler,et al.  Numerical Recipes in C: The Art of Scientific Computing , 1989 .

[14]  Ellen Yorke,et al.  Integrating respiratory gating into a megavoltage cone-beam CT system. , 2006, Medical physics.

[15]  P. Munro,et al.  Four-dimensional cone beam CT with adaptive gantry rotation and adaptive data sampling. , 2007, Medical physics.

[16]  E. Sidky,et al.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization , 2008, Physics in medicine and biology.

[17]  William H. Press,et al.  Numerical recipes in C. The art of scientific computing , 1987 .

[18]  Berthold K. P. Horn,et al.  Determining Optical Flow , 1981, Other Conferences.

[19]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[20]  G. Herman,et al.  Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography. , 1970, Journal of theoretical biology.

[21]  Henrik Turbell,et al.  Cone-Beam Reconstruction Using Filtered Backprojection , 2001 .

[22]  Graeme C. Mc Kinnon,et al.  Towards Imaging the Beating Heart Usefully with a Conventional CT Scanner , 1981, IEEE Transactions on Biomedical Engineering.

[23]  Uwe Oelfke,et al.  Linac-integrated 4D cone beam CT: first experimental results , 2006, Physics in medicine and biology.