Excimer laser instrumentation and technique for human corneal surgery.

The design and development of the instrumentation utilized during the clinical and histopathologic evaluations of the first human eyes treated by argon fluoride excimer laser radiation are described. The laser, optical, alignment, measurement, and control subsystems required for this research were constructed to create a laser beam that has an axially symmetric energy distribution, can be calibrated and measured, can be aligned with the target tissue, and can be manipulated to excise surface tissue. The use of this excimer laser system has demonstrated that a nonuniform superficial lamellar keratectomy can be produced to excise areas of opacified, scarred, or abnormal cornea or to create a new anterior corneal curvature in attempts to correct refractive errors.

[1]  S. Trokel,et al.  Excimer laser surgery of the cornea. , 1983, American journal of ophthalmology.

[2]  R. Srinivasan,et al.  Ablative photodecomposition: action of far-ultraviolet (193 nm) laser radiation on poly(ethylene terephthalate) films , 1982 .

[3]  R. Krueger,et al.  A comparative study of corneal incisions induced by diamond and steel knives and two ultraviolet radiations from an excimer laser. , 1986, The British journal of ophthalmology.

[4]  S. Trokel,et al.  Excimer laser radial keratotomy. , 1985, Ophthalmology.

[5]  M. Wolbarsht,et al.  Laser surgery: CO2or HF , 1984, IEEE Journal of Quantum Electronics.

[6]  J. Marshall,et al.  An ultrastructural study of corneal incisions induced by an excimer laser at 193 nm. , 1985, Ophthalmology.

[7]  J. Taboada,et al.  Response of the corneal epithelium to KrF excimer laser pulses. , 1981, Health physics.

[8]  Stephen Rothery,et al.  Stromal remodelling following photorefractive keratectomy , 1987 .

[9]  R. Trebino Achromatic N-prism beam expanders: optimal configurations. , 1985, Applied optics.

[10]  R. Srinivasan,et al.  Self-developing photoetching of poly(ethylene terephthalate) films by far-ultraviolet excimer laser radiation , 1982 .

[11]  W. Veldkamp,et al.  Compact, collinear, and variable anamorphic-beam compressor design. , 1982, Applied optics.

[12]  J. Jester,et al.  Keratophakia and keratomileusis: histopathologic, ultrastructural, and experimental studies. , 1984, Ophthalmology.

[13]  R. Srinivasan,et al.  Laser ablation of organic polymers: Microscopic models for photochemical and thermal processes , 1985 .

[14]  F Hillenkamp,et al.  Excimer laser ablation of the cornea and lens. Experimental studies. , 1985, Ophthalmology (Rochester, Minn.).

[15]  Bodil Braren,et al.  Photochemical cleavage of a polymeric solid: details of the ultraviolet laser ablation of poly(methyl methacrylate) at 193 nm and 248 nm , 1986 .

[16]  R R Krueger,et al.  Quantitation of corneal ablation by ultraviolet laser light. , 1985, Archives of ophthalmology.