Fast-acquisition multispectral FLIM by parallel TCSPC

Currently used TCSPC FLIM systems are characterised by high counting efficiency, high time resolution, and multiwavelength capability. The systems are, however, restricted to count rates on the order of a few MHz. In the majority of applications, such as FRET or tissue autofluorescence, the photostability of the samples limits the count rate to much lower values. The limited counting capability of the hardware is therefore no problem. However, if FLIM is used for samples containing highly photostable fluorophores at high concentrations the available count rates can exceed the counting capability of a single TCSPC channel. In this paper we describe a TCSPC FLIM system that uses 8 parallel TCSPC channels to record FLIM data at a peak count rate on the order of 50•106 s-1. By using a polychromator for spectral dispersion and a multi-channel PMT for detection we obtain multi-spectral FLIM data at acquisition times on the order of one second. We demonstrate the system for recording transient lifetime effects in the chloroplasts in live plants.

[1]  R. Ballew,et al.  An error analysis of the rapid lifetime determination method for the evaluation of single exponential decays , 1989 .

[2]  Axel Bergmann,et al.  High-speed FLIM data acquisition by time-correlated single-photon counting , 2004, SPIE BiOS.

[3]  Yuexin Liu,et al.  Membrane order and molecular dynamics associated with IgE receptor cross-linking in mast cells. , 2007, Biophysical journal.

[4]  K. König,et al.  Fluorescence lifetime imaging by time‐correlated single‐photon counting , 2004, Microscopy research and technique.

[5]  Axel Bergmann,et al.  Interaction of PSD-95 with potassium channels visualized by fluorescence lifetime-based resonance energy transfer imaging. , 2004, Journal of biomedical optics.

[6]  Jürgen Wolfrum,et al.  How many photons are necessary for fluorescence-lifetime measurements? , 1992 .

[7]  Karsten König,et al.  Clinical multiphoton tomography , 2008, Journal of biophotonics.

[8]  Wolfgang Becker,et al.  How fast can TCSPC FLIM be made? , 2007, SPIE Optics East.

[9]  D. O'connor,et al.  Time-Correlated Single Photon Counting , 1984 .

[10]  W. Becker Advanced Time-Correlated Single Photon Counting Techniques , 2005 .

[11]  Karsten König,et al.  Prolonged irradiation of enhanced cyan fluorescent protein or Cerulean can invalidate Forster resonance energy transfer measurements. , 2008, Journal of biomedical optics.

[12]  A. Bergmann,et al.  Multispectral fluorescence lifetime imaging by TCSPC , 2007, Microscopy research and technique.

[13]  Jens Eickhoff,et al.  In vivo multiphoton fluorescence lifetime imaging of protein-bound and free nicotinamide adenine dinucleotide in normal and precancerous epithelia. , 2007, Journal of biomedical optics.