Prostate cancer diagnosis using a saturation needle biopsy technique after previous negative sextant biopsies.

PURPOSE We hypothesized that markedly increasing the number of cores obtained during prostate needle biopsy may improve the cancer detection rate in men with persistent indications for repeat biopsy. MATERIALS AND METHODS We performed saturation ultrasound guided transrectal prostate needle biopsy in 224 men under anesthesia in an outpatient surgical setting in whom previous negative biopsies had been performed in the office. The mean number of previous sextant biopsy sessions plus or minus standard deviation before saturation biopsy was 1.8 (range 1 to 7). A mean of 23 saturation biopsy cores (range 14 to 45) were distributed throughout the whole prostate, including the peripheral, medial and anterior regions. Indications for repeat biopsy were persistent elevated serum prostate specific antigen (PSA) in 108 cases, persistent elevated PSA and abnormal rectal examination in 27, persistent abnormal rectal examination in 4, high grade prostatic intraepithelial neoplasia in the previous biopsy in 64 and atypia in the previous biopsy in 21. RESULTS Cancer was detected in 77 of 224 patients (34%). The number of previous negative sextant biopsies was not predictive of subsequent cancer detection by saturation biopsy. Median PSA was 8.7 ng./ml. and median PSA velocity was 0.63 ng./ml. yearly. Of the 77 patients in whom cancer was detected radical prostatectomy was performed in 52. Pathological stage was pT2 in 48 patients and pT3 in 4, while Gleason score was 4 to 5, 6 to 7 and 8 in 5, 46 and 1, respectively. At prostatectomy median cancer volume was 1.04 cc and 85.7% of removed tumors were clinically significant, assuming a 3-year doubling time. The overall complication rate for saturation needle biopsy was 12% and hematuria requiring hospital admission was the most common event. CONCLUSIONS Saturation needle biopsy of the prostate is a useful diagnostic technique in men at risk for prostate cancer with previous negative office biopsies. This technique allows adequate sampling of the whole prostate gland and has a detection rate of 34% in this cohort of patients.

[1]  D. McCullough,et al.  Prostate cancer diagnosed by the 5 region biopsy method is significant disease. , 1998, The Journal of urology.

[2]  D. Johnston,et al.  Prostate cancer detection: relationship to prostate size. , 1999, Urology.

[3]  D. Johnston,et al.  Optimization of prostate biopsy strategy using computer based analysis. , 1997, The Journal of urology.

[4]  C. Amling,et al.  Extensive repeat transrectal ultrasound guided prostate biopsy in patients with previous benign sextant biopsies. , 2000, The Journal of urology.

[5]  W. Catalona,et al.  Prostatic transition zone biopsies in men with previous negative biopsies and persistently elevated serum prostate specific antigen values. , 1995, The Journal of urology.

[6]  W. Ellis,et al.  Repeat prostate needle biopsy: who needs it? , 1995, The Journal of urology.

[7]  P. Humphrey,et al.  Clinical and pathologic tumor characteristics of prostate cancer as a function of the number of biopsy cores: a retrospective study. , 1998, Urology.

[8]  J. Melamed,et al.  Two consecutive sets of transrectal ultrasound guided sextant biopsies of the prostate for the detection of prostate cancer. , 1998, The Journal of urology.

[9]  D L McCullough,et al.  Systematic 5 region prostate biopsy is superior to sextant method for diagnosing carcinoma of the prostate. , 1997, The Journal of urology.

[10]  M. Terris,et al.  Random systematic versus directed ultrasound guided transrectal core biopsies of the prostate. , 1989, The Journal of urology.

[11]  John T. Wei,et al.  The influence of prostate size on cancer detection. , 1995, Urology.

[12]  L. Chang,et al.  Participation of paraventricular nucleus of hypothalamus in central regulation of penile erection in the rat. , 1997, The Journal of urology.

[13]  K. Shinohara,et al.  Prospective evaluation of lateral biopsies of the peripheral zone for prostate cancer detection. , 1998, The Journal of urology.

[14]  V. Reuter,et al.  Clinical significance of repeat sextant biopsies in prostate cancer patients. , 1997, Urology.

[15]  P. Walsh,et al.  Use of repeat sextant and transition zone biopsies for assessing extent of prostate cancer. , 1997, The Journal of urology.

[16]  T. Stamey,et al.  Effect of Ageing on Morphologic and Clinical Predictors of Prostate Cancer Progression , 2000 .

[17]  Experience with vasal sperm aspiration. , 1998, The Journal of urology.

[18]  L. Holmberg,et al.  The sextant protocol for ultrasound-guided core biopsies of the prostate underestimates the presence of cancer. , 1997, Urology.

[19]  W. Fair,et al.  Prevalence and predictors of a positive repeat transrectal ultrasound guided needle biopsy of the prostate. , 1997, The Journal of urology.

[20]  O. Nakashima,et al.  Necessity of repeat biopsies in men for suspected prostate cancer , 1999, International journal of urology : official journal of the Japanese Urological Association.

[21]  W. Catalona,et al.  Detection of organ-confined prostate cancer is increased through prostate-specific antigen-based screening. , 1993, JAMA.

[22]  W. Catalona,et al.  Serial prostatic biopsies in men with persistently elevated serum prostate specific antigen values. , 1994, The Journal of urology.

[23]  K. Shinohara,et al.  The optimal systematic prostate biopsy scheme should include 8 rather than 6 biopsies: results of a prospective clinical trial. , 2000, The Journal of urology.

[24]  H. Klocker,et al.  Frequency and clinical significance of transition zone cancer in prostate cancer screening , 1997, The Prostate.

[25]  M M Elhilali,et al.  Outcome of sextant biopsy according to gland volume. , 1997, Urology.

[26]  H. Stricker,et al.  Detection of non-palpable prostate cancer. A mathematical and laboratory model. , 1993, British journal of urology.

[27]  V. Barbetti,et al.  Results of rebiopsy for suspected prostate cancer in symptomatic men with elevated PSA levels. , 1997, European urology.

[28]  W. Fair,et al.  Repeat transrectal ultrasound-guided prostate biopsy: a strategy to improve the reliability of needle biopsy grading in patients with well-differentiated prostate cancer. , 1998, Urology.

[29]  Y. Arai,et al.  Value of Systematic Transition Zone Biopsy in the Detection of Prostate Cancer , 1997, International journal of urology : official journal of the Japanese Urological Association.

[30]  D. Bostwick,et al.  The definition and preoperative prediction of clinically insignificant prostate cancer. , 1996, JAMA.

[31]  M. Brawer,et al.  Repeat ultrasound guided prostate needle biopsy: use of free-to-total prostate specific antigen ratio in predicting prostatic carcinoma. , 1998, The Journal of urology.

[32]  W. Fair,et al.  Incidence and clinical significance of false-negative sextant prostate biopsies. , 1998, The Journal of urology.

[33]  R W Veltri,et al.  Analysis of repeated biopsy results within 1 year after a noncancer diagnosis. , 2000, Urology.

[34]  P. Humphrey,et al.  Repeat biopsy strategy in men with isolated prostatic intraepithelial neoplasia on prostate needle biopsy. , 1996, The Journal of urology.

[35]  M. Terris,et al.  Comparison of mid-lobe versus lateral systematic sextant biopsies in the detection of prostate cancer. , 1997, Urologia internationalis.

[36]  C. Roehrborn,et al.  Diagnostic yield of repeated transrectal ultrasound-guided biopsies stratified by specific histopathologic diagnoses and prostate specific antigen levels. , 1996, Urology.

[37]  J. Epstein,et al.  Repeat biopsy strategies for men with atypical diagnoses on initial prostate needle biopsy , 1999 .