Study on Protection Coordination Between Protective Devices in a Power Distribution System With an SFCL

As one of the countermeasures to solve the increase problem of the fault current in a power system, the superconducting fault current limiter (SFCL) has been noticed as the attractive device because it has no power loss in a normal time and can limit the fault current rapidly without additional device to detect the fault current. However, the introduction of the SFCL in a power distribution system affects the protection coordination between the existing protective devices such as the over-current relay (OCR) and the recloser, which causes the operation of the protective devices to get out of their original setting values. Therefore, the analysis on the effect of the SFCL introduction on the existing protective devices is required and the method to keep the protection coordination between the protective devices in a power system with the SFCL should be first considered. In this paper, the protection coordination experiments between the OCR and the recloser in the simulated power distribution system with the SFCL were performed. Based on the experimental results, the influence of the SFCL on the operation of these protective devices was analysed and the methods to keep the protection coordination between the OCR and the recloser in a power distribution system with the SFCL were discussed.

[1]  Sung-Hun Lim,et al.  Fault current limiting characteristics due to winding direction between coil 1 and coil 2 in a flux-lock type SFCL , 2004 .

[2]  H.-W. Neumuller,et al.  Resistive current limiters with YBCO films , 1997, IEEE Transactions on Applied Superconductivity.

[3]  Seong-Woo Yim,et al.  Introduction of a Hybrid SFCL in KEPCO Grid and Local Points at Issue , 2009, IEEE Transactions on Applied Superconductivity.

[4]  Yu Jiang,et al.  Comparison of superconducting fault current limiter in power system , 2001, 2001 Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.01CH37262).

[5]  H. Yamaguchi,et al.  Characteristics analysis of transformer type superconducting fault current limiter , 2004, IEEE Transactions on Applied Superconductivity.

[6]  Liangzhen Lin,et al.  Application studies of superconducting fault current limiters in electric power systems , 2002 .

[7]  I.S. Oh,et al.  Design and Experiments of Novel Hybrid Type Superconducting Fault Current Limiters , 2008, IEEE Transactions on Applied Superconductivity.

[8]  M. St. John,et al.  Coordinating overcurrent protection devices , 1996 .

[9]  Sung-Hun Lim,et al.  Fault Current Limiting Characteristics of Separated and Integrated Three-Phase Flux-Lock Type SFCLs , 2007 .

[10]  Jae Young Yoon,et al.  A Study on SFCL Systems for Korean Power System Application , 2006, 2005/2006 IEEE/PES Transmission and Distribution Conference and Exhibition.