Reliability of 3D Lower Extremity Movement Analysis by Means of Inertial Sensor Technology during Transitional Tasks

This study assesses the reliability and agreement of trunk and lower limb joints’ 3D kinematics, measured by inertial measurement units, during walking and more demanding movement tasks. For data analysis, tasks were divided in open and closed chain phases. Twenty healthy participants were included. On day one, measurements were conducted by “Operator 1” and “Operator 2” to determine between-operator reliability/agreement. On day two, the measurements were conducted by Operator 1, in order to determine within-session reliability/agreement. Furthermore, between-session reliability/agreement was assessed based on data from Operator 1, captured on day one and two. Within-session reliability/agreement was high, and better than between-session and between-operator results for all tasks. The results for walking were generally better than for other movement tasks, for all joint kinematics, and for both open and closed chain phases. Only for the ab/adduction and flexion/extension angles during forward and sideward lunge, reliability and agreement results were comparable to walking, for both the open and closed chain phases. The fact that lunges show similar reliability results than walking for open and closed chain phases, but require more motor control to perform, indicates that the performance of lunges might be interesting to use in further research aiming to identify kinematic differences between populations.

[1]  Aurelio Cappozzo,et al.  Joint kinematics estimate using wearable inertial and magnetic sensing modules. , 2008, Gait & posture.

[2]  A Forner-Cordero,et al.  Study of the motion artefacts of skin-mounted inertial sensors under different attachment conditions , 2008, Physiological measurement.

[3]  M. Hunt,et al.  Trunk lean gait modification and knee joint load in people with medial knee osteoarthritis: The effect of varying trunk lean angles , 2012, Arthritis care & research.

[4]  M. Morris,et al.  The reliability of three-dimensional kinematic gait measurements: a systematic review. , 2009, Gait & posture.

[5]  P. Veltink,et al.  Estimating orientation with gyroscopes and accelerometers. , 1999, Technology and health care : official journal of the European Society for Engineering and Medicine.

[6]  Hartmut Witte,et al.  ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion--part I: ankle, hip, and spine. International Society of Biomechanics. , 2002, Journal of biomechanics.

[7]  Christian Larue,et al.  Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis , 2017, Medical & Biological Engineering & Computing.

[8]  Angkoon Phinyomark,et al.  Reliability of gait analysis using wearable sensors in patients with knee osteoarthritis. , 2016, Journal of biomechanics.

[9]  Antonio I Cuesta-Vargas,et al.  The use of inertial sensors system for human motion analysis , 2010, Physical therapy reviews : PTR.

[10]  J. Fleiss,et al.  Intraclass correlations: uses in assessing rater reliability. , 1979, Psychological bulletin.

[11]  B M Jolles,et al.  Functional calibration procedure for 3D knee joint angle description using inertial sensors. , 2009, Journal of biomechanics.

[12]  J. Weir Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. , 2005, Journal of strength and conditioning research.

[13]  I Jonkers,et al.  Mobile assessment of the lower limb kinematics in healthy persons and in persons with degenerative knee disorders: A systematic review. , 2018, Gait & posture.

[14]  Christian Larue,et al.  Accuracy and repeatability of single-pose calibration of inertial measurement units for whole-body motion analysis. , 2017, Gait & posture.

[15]  Eduardo Palermo,et al.  Experimental evaluation of accuracy and repeatability of a novel body-to-sensor calibration procedure for inertial sensor-based gait analysis , 2014 .

[16]  Corina Nüesch,et al.  Measuring joint kinematics of treadmill walking and running: Comparison between an inertial sensor based system and a camera-based system. , 2017, Journal of biomechanics.

[17]  Peter H. Veltink,et al.  Ambulatory Position and Orientation Tracking Fusing Magnetic and Inertial Sensing , 2007, IEEE Transactions on Biomedical Engineering.

[18]  W. Potthast,et al.  Motion analysis of patients after knee arthroplasty during activities of daily living--a systematic review. , 2015, Gait & posture.

[19]  Kate Button,et al.  Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity , 2018, Sensors.