Deep learning segmentation for optical coherence tomography measurements of the lower tear meniscus.

The tear meniscus contains most of the tear fluid and therefore is a good indicator for the state of the tear film. Previously, we used a custom-built optical coherence tomography (OCT) system to study the lower tear meniscus by automatically segmenting the image data with a thresholding-based segmentation algorithm (TBSA). In this report, we investigate whether the results of this image segmentation algorithm are suitable to train a neural network in order to obtain similar or better segmentation results with shorter processing times. Considering the class imbalance problem, we compare two approaches, one directly segmenting the tear meniscus (DSA), the other first localizing the region of interest and then segmenting within the higher resolution image section (LSA). A total of 6658 images labeled by the TBSA were used to train deep convolutional neural networks with supervised learning. Five-fold cross-validation reveals a sensitivity of 96.36% and 96.43%, a specificity of 99.98% and 99.86% and a Jaccard index of 93.24% and 93.16% for the DSA and LSA, respectively. Average segmentation times are up to 228 times faster than the TBSA. Additionally, we report the behavior of the DSA and LSA in cases challenging for the TBSA and further test the applicability to measurements acquired with a commercially available OCT system. The application of deep learning for the segmentation of the tear meniscus provides a powerful tool for the assessment of the tear film, supporting studies for the investigation of the pathophysiology of dry eye-related diseases.

[1]  Leixin Zhou,et al.  Multiple surface segmentation using convolution neural nets: application to retinal layer segmentation in OCT images , 2018, Biomedical optics express.

[2]  Johnny L Gayton,et al.  etiology , prevalence , and treatment of dry eye disease , 2009 .

[3]  Angelika Unterhuber,et al.  In vivo tear film thickness measurement and tear film dynamics visualization using spectral domain optical coherence tomography. , 2015, Optics express.

[4]  J. Fernández-Vigo,et al.  Lower Tear Meniscus Measurements Using a New Anterior Segment Swept-Source Optical Coherence Tomography and Agreement With Fourier-Domain Optical Coherence Tomography. , 2017, Cornea.

[5]  D. Schaumberg,et al.  Prevalence of Diagnosed Dry Eye Disease in the United States Among Adults Aged 18 Years and Older. , 2017, American journal of ophthalmology.

[6]  J. Wolffsohn,et al.  TFOS DEWS II Diagnostic Methodology report. , 2017, The ocular surface.

[7]  Leopold Schmetterer,et al.  Automated segmentation of dermal fillers in OCT images of mice using convolutional neural networks. , 2019, Biomedical optics express.

[8]  Xiangjian He,et al.  Deep Learning Techniques for Medical Image Segmentation: Achievements and Challenges , 2019, Journal of Digital Imaging.

[9]  Chong Wang,et al.  Automatic segmentation of nine retinal layer boundaries in OCT images of non-exudative AMD patients using deep learning and graph search. , 2017, Biomedical optics express.

[10]  K. Tsubota,et al.  Noninvasive interference tear meniscometry in dry eye patients with Sjögren syndrome. , 2007, American journal of ophthalmology.

[11]  L. Tong,et al.  Repeatability of tear meniscus evaluation using spectral-domain Cirrus® HD-OCT and time-domain Visante® OCT. , 2015, Contact lens & anterior eye : the journal of the British Contact Lens Association.

[12]  Yue Wu,et al.  Deep-Learning Based, Automated Segmentation of Macular Edema in Optical Coherence Tomography , 2017, bioRxiv.

[13]  Satoru Yamagami,et al.  Tear meniscus evaluation by anterior segment swept-source optical coherence tomography. , 2012, American journal of ophthalmology.

[14]  Angelika Unterhuber,et al.  Measurement of tear film thickness using ultrahigh-resolution optical coherence tomography. , 2013, Investigative ophthalmology & visual science.

[15]  Andreas Holzinger,et al.  Biomedical image augmentation using Augmentor , 2019, Bioinform..

[16]  H. Lew,et al.  Tear meniscus measurement in nasolacrimal duct obstruction patients with Fourier‐domain optical coherence tomography: novel three‐point capture method , 2012, Acta ophthalmologica.

[17]  J. Mainstone,et al.  Tear meniscus measurement in the diagnosis of dry eye. , 1996, Current eye research.

[18]  L. Schmetterer,et al.  Automatic assessment of tear film and tear meniscus parameters in healthy subjects using ultrahigh-resolution optical coherence tomography. , 2019, Biomedical optics express.

[19]  Leopold Schmetterer,et al.  CorneaNet: fast segmentation of cornea OCT scans of healthy and keratoconic eyes using deep learning. , 2019, Biomedical optics express.

[20]  David Huang,et al.  Reproducibility of tear meniscus measurement by Fourier-domain optical coherence tomography: a pilot study. , 2008, Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye.

[21]  Nitish Srivastava,et al.  Dropout: a simple way to prevent neural networks from overfitting , 2014, J. Mach. Learn. Res..

[22]  Bianca S. Gerendas,et al.  Fully Automated Detection and Quantification of Macular Fluid in OCT Using Deep Learning. , 2017, Ophthalmology.

[23]  Leopold Schmetterer,et al.  Anterior segment optical coherence tomography , 2018, Progress in Retinal and Eye Research.

[24]  S Kinoshita,et al.  The Height and Radius of the Tear Meniscus and Methods for Examining These Parameters , 2000, Cornea.